Introduction
A.GEWINN Infra LLP
B.Head Office –Mumbai
C.Representative offices :
1.Pune
2.Chennai
3.Bangalore
D.Deals in Safety Products & Projects
We offer:
• Products
a. Innovative Safety Products
i. BONPET –Automatic Fire Extinguisher
ii. Shield –Fire Extinguisher (ABC&F Type)
iii. Fire Trolley –Emergency Fire Fighting System
iv. ELSA, Singapore –Water Leak Detection System
• Projects
a. Fire Suppression Tubing System
b. iBMSin Data Centers
i. Fire Alarm System v. CCTV
ii. Fire Suppression System (FM200 / Novec1230)vi. Water Leak Detection System
iii. Aspiration System (VESDA) vii. Rodent Repellant
iv. Access Control viii.BMS Integration
The Need For Rapid Fire
Extinguishment -RFE
1
TIME POWER EQUATION
INITIAL STAGE CRITICAL STAGE BLAZE STAGE
TEMPERATURE (in degrees)
50
100
1000
Fire Extinguishment using Water
•Thebestwaytoremoveheatistodumpwateronthefirebut,
dependingonthetypeoffire,thisisnotalwaysthebestoption.
•Themostcommonagentiswater;however,itcannotbeusedfor
classBorCfiresbecauseitisconductive.
•AlthoughonlyeffectiveononlyClassAfires,theyhavethe
advantageofbeinginexpensivetooperateandcausingminimal
damageandcleanup.
•WaterextinguishersorAPWextinguishers(air-pressurizedwater)
aresuitableforclassAfiresonly.
•Watercannotbeusedongreasefires,electricalfiresorclassDfires
-theflameswillspreadandmakethefirebigger!
•FIRERE-IGNITIONRISKISHIGH
6
Fire Extinguishment with X Fire Pro
X-Fire Pro, the most powerful fire-fighting liquid is
Extinguishing time and re-ignition
Puts out fire at a record-breaking time in
seconds
No re-ignition effect
•Extensive Coverage
X-Fire can be used for A, B, C, E and F classes
of fire.
Eco-friendly
Consumes as less as only 3/4 of water usually
used in extinguishing fire
Harmless on skin
Non toxic
Bio-degradable
Stain-free on any surface
7
Working Principle of X Fire Pro
•Based on Fire Triangle, the combustion process requires three
factors: fuel, heat and oxygen.
•X-Fire extinguishing liquid affects the burning zone in three
ways namely:
•Producing extreme cooling effect
•Emitting of oxygen from fire volume
•Spreading a thin film type liquid layer preventing
further re-ignition
•X-Fire liquid has a shelf life of 10 years.
Working Principle of X-Fire
Pro Extinguishing Liquid
•X-Fire Pro owes its extinguishing efficacyto the joint actuation
of 4 main effects:
•Smothering-X-Fire Pro displaces the oxygen
thus producing a smothering effect.
•Cooling:X-Fire Pro which causes instant deep cooling
effect thereby reducing the heat radiation drastically. This
action minimizes the effect of 3
rd
degree burns.
•Attenuation:X-Fire Pro absorbs a great amount
of radiant heat, thus, avoiding re-ignition and fire re-lapse.
Automatic Fire Extinguisher -BONPET
Automaticfire
extinguishing MobileExtinguishing Dilutionwithwater
How to use
TheBONPETfire extinguisherampoule'sautomaticactivation
Whathappens ifthe fire breaksoutin a closed areaprotectedby BONPET?
Due to fire the temperatureincreasesand as a resultofitthe extinguisher
liquidalso gets warmandexpandin the ampoule. When the temperatureof
theliquidgets 85C°+/-5C°itis convertedinto vapourand as a resultofthe
changingofthe liquidstatepressureisgenerated/created whichbreaksthe
glass into pieces.Thevapourspurts in the areastarting endotherm
processes whichtakeenergy/powerfrom the fire, thus dousing the fire
instantaneously
How it works
Please play the Video
Advantages of BONPET System
• High efficiency by extinguishing A, B, C and F types of fire
• 10 years warranty, No refilling cost
• Used as a Hand grenade
• The extinguishing liquid mixed with water can be used for Big Fires
• The installation is simple, necessary just 2 screws
• Work even in extreme weather conditions (from -23 C to 80 C) & operates reliably
• Takes up very little place
Advantages of BONPET System
• Doesn’t need to lay a cable, power supply or water pipe
• Doesn’t need any maintenance
• It can be used simply in case of panic situation
• The special glass of the ampoule, broken into pieces without edges
• It doesn't cause damage in electrical systems, machines
• Environment-friendly
• Non toxic effect on humans & other organisms
Comparisonofadvantagesordisadvantagesofthedifferentfireclasses:
A–Commonfire(solidflammablesubstances)
C–Flammablegas
B–Burningofflammableliquids(fuel)
F-Firemadeofvegetableoilandkitchenfat
“TheBonpetampouleworkswithgreatinsecurityinautomaticmodeofoperationbyextinguishing
ELECTRICALFIRES.ItisrecommendedtoinstallBonpetampoulesfor keepsafeandprotectelectrical
device,computercenters,transformersandelectricaldistributorsystems(till60000V.)”
HALONS AND
TYPEOFBURNINGMATERIAL BONPET WATER THEIR ABC
POWDER SUBSTITUES
A WoodenMaterial
Paper,Textil,Fabrics
Clothes,Bedlinen
Rubber,Celluloid
Hlastic
B
Petrol
FoodGreases
Other oils
F
vegetable oil,kitchenfat
verygood good bad good
verygood good bad good
verygood good bad good
verygood good bad good
verygood good good good
good bad good good
verygood bad good good
verygood bad good good
verygood bad good good
Comparison
Certifications -BONPET System
Emergency Fire Response Kit -Shield
Facilitatefightingfirefromadistanceofabout15–20feetindoor
SingleHandOperationandmulti-angledischargefacilitating
extinguishmentofceilingheightfires
OneextinguishertohandlemultipletypeoffirerisksuchasCookingOil
fire(ClassF)&LiveElectricalfire(classE),andClassA,BandC.
NoRe-ignitionoffireastheextinguishingagentformsathinfilmonthe
surface
MaintenanceFree
Biodegradable&negligibleresidualafteruse
4to6unitsofhand-heldfireextinguishersarepackagedinastrongbagto
facilitatecarryingittothefirespoteasily.
Hand Held Fire Extinguisher
Comparison between X-Fire Shield &
Conventional Extinguishers
Parameters X-Fire Shield Conventional Extinguishers
Proximity of fighting fire 20 to 25 feet 4to 7 feet
Ceiling Height Fire Can be used to extinguish
ceiling height fire
Cannot be used to fight ceiling height fire
Ease of operation & training Hand-held Operation with
minimum training
Both hand operation with intensive
training
Multiple threat points
capability
Possible Not possible
Class of Fire A,B,C,E and F A,B and C
Re-ignition Nil Possible
Maintenance Nil Periodic maintenance
Weight 700 gms 3kgs -5kgs
Equipment handling risk Nil Can cause severe damage to the user and
even fatality
Discharge time 30 seconds per Shield 8 seconds
Residue Negligible Noticeable
Certificates & Testimonials
Certifying Agency
TUV, Lloyds,
Underwriter’s Laboratories
Register for Shipping
National Emergency Directorate
Institute of Quality and Metrology
Ministry of Defense
Administration for Civil Protection and Disaster Relief
31
Monday, June 13, 2016 32
Application Areas
Segments Segments
IT Parks Warehousing
Shopping Malls Manufacturing
Colleges
SEZ’s
Hospitals Hotels
Emergency Fire Fighting System –Fire Trolley
Emergency Fire Fighting System (Fire Trolley)
•World’s first Battery OR Petrol Engine operated Emergency Fire Fighting System.
•Would replace 45 conventional extinguishers
•High pressure diaphragm pump with a flow rate of 25 liters per minute
•System capacity of 150 liters would provide 6 minutes of fire fighting equivalent to 45 conventional extinguishers
•Ideal for facilities without sprinkler or hydrant for Emergency Fire Response
•Can lance a distance of 40 feet as against 3 to 5 meters by conventional extinguisher
•Both jet type as well as mist type of spraying is available
•Trolley mounted provides mobility
•Equipment warranty of 5 years and Liquid performance warranty of 7 years
Details of Emergency Fire Fighting System –Fire Trolley
Automatic Fire Suppression Tubing System
Automatic
Fire
Suppression
Tubing
System
FireSuppressionSystemsprovideCost-Effective,Stand-Alone,
AutomaticFireSuppressionSystemsforyourCriticalEquipment,
Electrical/TechnicalSystemsandvarioustypesofenclosures.
TheeffectivenessofagenuineFiretraceSystem,happensbyutilizing
theproprietaryFiretraceDetectionTubing(aLinearPneumaticHeat
Sensor),whichdetectsafireduetoprecisetemperaturesensitivity,
allowingoursystemstoreactquicklyandeffectively.
Thisuniquedetectioncanberunthroughthesmallestormost
complexenclosurestoensuredetectionisalwaysclose athand.
Automatic Fire Suppression Tubing System
The heart of the system is the Linear Heat Sensitivepneumatic polymer tubing. It
is connected at one end to aExtinguishing Agent Container, which the rest runs
throughthe risk area, in a predetermined manner. When the flametouches the
tubing and it reaches a temperature of 67 Deg. C,the tubing bursts at it hottest
point (which is nearest to themost vulnerable part of the fire), thus forming a
nozzle .
The pneumatic mechanism then triggers the valve of the extinguisher & sprays
the agent out directly into the fire, thus dousing the fire quicker than any other
technique on the market.
This path breaking system, is entirely automatic, and once installed, requires no
human help. Thus making it the method of choice for “Localized environments”,
or areas which are cordoned off or have an enclosed area (such as panels,
servers..)
Automatic Fire Suppression Tubing System
DIRECTRELEASE SYSTEMS
Firetrace’sfire protection –direct release systems utilize the
tube as both the “detection device” and “suppressant delivery. As the fire
begins, the portion of the tube nearest the point where the most heat is
detected ruptures, forming an effective spray nozzle.
The pressure will then drop as the Firetrace tube releases the entire
contents of the cylinder through the distribution nozzle to effectively
suppress the fire. More than one Firetrace tube can be used enabling the
system to cover more area. Our fire suppression systems are critical for
safety and protecting your valuable equipments
Automatic Fire Suppression System operates on 2 different Techniques:
Direct & Indirect
INDIRECTRELEASE SYSTEMS
Once the tubing senses the fire, it ruptures –resulting in a drop of pressure causing the
Indirect Valveto activate
This diverts flow from the detection tube tothe larger outlet ports
Then the fire suppression system kicks in –theExtinguishing Agent is discharged from the
cylinderthrough the diffuser nozzles, flooding the area in aproprietary mix of fire
extinguishing chemicals,effectively suppressing the fire quickly &thoroughly
This system is typically used in larger areas that require ahigh volume of Extinguishing
Agents, to effectivelysuppress the fire
Multiple diffuser nozzles may be added to meet thespecific Application /requirements
Automatic Fire Suppression System operates on 2 different Techniques:
Direct & Indirect
Entirelyautomated , doesnotrequireany external powersupply, thusit functions
perfectlyin casean absenceofelectricity
Instantdetectionand instant suppression,without anyHuman involvement
Thesystemisalwaysreadyto respond.Hencethereisno downtime
UsesNovec1230,DuPontFE-36,NAFP IV, NAFS 125,HCFC123 and Co2
Flexibletubingallowsprotectionofareasthat wereotherwiseimpossibleto protect
Simpledesign.Thesystemgetsinstalledina fewhours,whichmeansminimallabour
and downtime
Ruggeddesignoffersoutdoorand indoorvariantsofthetube,and it canwithstand
harshconditionswhereothertypesofsystemsmight berenderedinadequate.
Advantages
Installations
Installations
Early Warning Liquid Leak Detection System
OurExpertiseandStrength
EarlyWarningLiquidLeakLocatingSystems
ELSA(EarlyLeakSystemApparatus)
Specializedin Liquid Leak Detectionand Locating Systems.
(Liquids=water,bases,acids)
OnlymanufacturertoofferASIC(ApplicationSpecificIntegratedComponent)
designsolutionwithuniquefeature –Fail-Safe LoopBack.
(Alsoknown asClassA Wiringwhichiscommonlyusefor FireAlarmsystem).
AllControl Panelshavea Sensitivityadjustment whichiseasilycontrol at siteto
thesensedifferentamountofliquidat sitesand to meet variousrequirement.
FlexibleandCustomizedSystemsolutiontailoredto individualneeds.
(eg:customlengthofsensingcable nowastage)
No compromiseinourServicesandProduct Quality.
WidecoverageSalesnetworkwithlocalofficesorpartnersinmajorcities.
Our Expertise and Strength
Early Warning Liquid Leak Locating System
3L-TP/12(12.1 Inch Touch Panel).
•Pin-PointLeakLocationprecisely,toleranceis +/1m.
3L-SP/DP(SupervisePanel): Monitorup to 99 unitsof 3L-AP/3L-DP/3L-NDP
•(3L-SP/DP+3L-AP/3L-DP/3L-NDP)Systemsableto monitor up to anaccumulated
SensingCablelengthof20Km(200m x 100units).
3L-AP: Advanced Locating Panel+ LCDdisplay
•2x Relays (Leak);1x Relay(CableBreak)
optional:(1) ModbusTCP/IP(2) RS485(3) 4~20mAanalogueoutput(192m)
•SensingCableLength–up to 200m permodule.
3L-DP: (Locating PanelinM36 DIN-RailorIP65)
•1x Relay(CommonAlarm)andRS485Communication.
•SensingCableLength–up to 200m per module.
•VisualAlarmbyLEDlightindicator.
•NOTE:3L-NDPaddressablemoduleavailableupon request.
3L-NP:(Non-Locating Panelin M36 DIN-RailorIP65)
•1xRelay(CommonAlarm)
•SensingCableLength–up to 60mper module.
•AlarmbyBuzzerand LEDlightindicator
Product at a Glance –Control Panel
Early Warning Liquid Leak Locating System
ProductataGlance–SensingCable
EarlyWarningLiquidLeakLocatingSystems
3L-LS:
Application:
Diametersize:
Continuitywires:
Sensingwires:
Carrier:
Fireresistance:
Waterand slightly-corrosiveconductiveliquids.
6mmaverage.
White&Red insulatedwith flame-retardantpolymer.
2xBlackwires,semi-conductivepolymer.
Flame-retardantpolymer material with greenishcolorin high visibility.
Non-flamepropagatingand self-extinguishing.
3L-AS:
Application:
Diametersize:
Highly-corrosiveconductiveliquidssuch as 100% SulfuricAcid.
6mmaverage.
Continuitywires:White&Red insulatedwith fire-resistantfluoropolymer.
Sensingwires:
Carrier:
Fireresistance:
2xBlackwires,semi-conductivefire-resistantfluoropolymer.
Fire-resistantfluoropolymermaterialwithyellowishcolorinhigh visibility.
UL910(NFPA262),highestFire/Smokestandard.
SensingCable andJoints
offer“Cutto Length”cablein Hot-ShrinktubeorMale/Femaleconnectors.
Ultrasensitivesensingcable (e.g.DewPointappln)availableupon request.
Product at a Glance –Sensing Cable
Early Warning Liquid Leak Locating System
3L-TP/12–12.1InchTouchPanel
EarlyWarningLiquidLeakLocatingSystems
Pin-PointLeakLocationPrecisely,tolerance+/-1m.
(indicationbyREDDOT).
History/EventLog:5,000events.
“Freezing”ofselectedzone(s)duringmaintenance/repair
andnofaultmessagegenerated.
ReadilyconnecttoGSMmodem/dialerfor SMSfaultnotification
Modbus/TCPoptionavailable.
AbilitytoZoom-Inontoeachfloorplan.
VariessizesofLCDmonitoravailableuponrequest.
3L-TP/12-12.1 inch Touch Panel
Early Warning Liquid Leak Locating System
3L-SP/DP–SupervisingPanel
EarlyWarningLiquidLeakLocatingSystems
•Monitorupto99units(external):
either3L-APor3L-DPor3L-NDP.
•Max.accumulatedlength:
sensingcableup to 20,000m(200m x100).
•LCDdisplay:
4linesEnglish characters.Each zoneis
programmablebysoftware(up to 35characters).
•
•
Event–Log(896time-stampedeventsstored)
Failed-SafeLoopBackFeature(class A wiringsystem):
Continueto detectleakifthereis acablebreak
•
•
Sensitivitycanbeadjustedmanually.
CommunicationinterfacewithBMS/EMS
2x Drycontactrelayforleaks
2x Drycontactrelayforcable-break
High Levelinterfaceprotocol :RS485/Modbus
3L-SP/DP –Supervising Panel
Early Warning Liquid Leak Locating System
3L·LS-Sensor (S:) 3L·LS Senso CS2)
i i
~ ~
@
Red
SEN
@
n Bladt
ABLE
3L-AP: Sensingcable(S1,S2,… ,Sn)& Belden(8723) jumper(J1,J2,…,Jn)connection
withend termination.
Note: J1·• J2 1 •••• t-Jn~300 m
S1 +S2 -t-•••• t Sn <192
m
..
3LLS·Seruoi(Sn)
i
t
,~
Jumler Jn)\ JumJr(J2)
O@
White G~e
SING C
Uniquefeature–Fail-Safe
EarlyWarningLiquidLeakLocatingSystems
LoopBack
Fail-SafeLoopBackConnectionDiagram
Whenthereisacablebreak,thesensingcablewillbecutinto2separate
sections(S1a&S1b).
EitherS1a orS1bstillcancontinueto detectLiquidLeakage.
Unique Feature –Fail-Safe Loop Back
Early Warning Liquid Leak Locating System