GEWINN Company Profile

DineshKumar1893 657 views 69 slides Jan 29, 2017
Slide 1
Slide 1 of 69
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53
Slide 54
54
Slide 55
55
Slide 56
56
Slide 57
57
Slide 58
58
Slide 59
59
Slide 60
60
Slide 61
61
Slide 62
62
Slide 63
63
Slide 64
64
Slide 65
65
Slide 66
66
Slide 67
67
Slide 68
68
Slide 69
69

About This Presentation

No description available for this slideshow.


Slide Content

GEWINN Infra LLP –Company Profile

Introduction
A.GEWINN Infra LLP
B.Head Office –Mumbai
C.Representative offices :
1.Pune
2.Chennai
3.Bangalore
D.Deals in Safety Products & Projects

We offer:
• Products
a. Innovative Safety Products
i. BONPET –Automatic Fire Extinguisher
ii. Shield –Fire Extinguisher (ABC&F Type)
iii. Fire Trolley –Emergency Fire Fighting System
iv. ELSA, Singapore –Water Leak Detection System
• Projects
a. Fire Suppression Tubing System
b. iBMSin Data Centers
i. Fire Alarm System v. CCTV
ii. Fire Suppression System (FM200 / Novec1230)vi. Water Leak Detection System
iii. Aspiration System (VESDA) vii. Rodent Repellant
iv. Access Control viii.BMS Integration

The Need For Rapid Fire
Extinguishment -RFE
1
TIME POWER EQUATION
INITIAL STAGE CRITICAL STAGE BLAZE STAGE
TEMPERATURE (in degrees)
50
100
1000

Fire Extinguishment using Water
•Thebestwaytoremoveheatistodumpwateronthefirebut,
dependingonthetypeoffire,thisisnotalwaysthebestoption.
•Themostcommonagentiswater;however,itcannotbeusedfor
classBorCfiresbecauseitisconductive.
•AlthoughonlyeffectiveononlyClassAfires,theyhavethe
advantageofbeinginexpensivetooperateandcausingminimal
damageandcleanup.
•WaterextinguishersorAPWextinguishers(air-pressurizedwater)
aresuitableforclassAfiresonly.
•Watercannotbeusedongreasefires,electricalfiresorclassDfires
-theflameswillspreadandmakethefirebigger!
•FIRERE-IGNITIONRISKISHIGH

6
Fire Extinguishment with X Fire Pro
X-Fire Pro, the most powerful fire-fighting liquid is
Extinguishing time and re-ignition
Puts out fire at a record-breaking time in
seconds
No re-ignition effect
•Extensive Coverage
X-Fire can be used for A, B, C, E and F classes
of fire.
Eco-friendly
Consumes as less as only 3/4 of water usually
used in extinguishing fire
Harmless on skin
Non toxic
Bio-degradable
Stain-free on any surface

7
Working Principle of X Fire Pro
•Based on Fire Triangle, the combustion process requires three
factors: fuel, heat and oxygen.
•X-Fire extinguishing liquid affects the burning zone in three
ways namely:
•Producing extreme cooling effect
•Emitting of oxygen from fire volume
•Spreading a thin film type liquid layer preventing
further re-ignition
•X-Fire liquid has a shelf life of 10 years.

Working Principle of X-Fire
Pro Extinguishing Liquid
•X-Fire Pro owes its extinguishing efficacyto the joint actuation
of 4 main effects:
•Smothering-X-Fire Pro displaces the oxygen
thus producing a smothering effect.
•Cooling:X-Fire Pro which causes instant deep cooling
effect thereby reducing the heat radiation drastically. This
action minimizes the effect of 3
rd
degree burns.
•Attenuation:X-Fire Pro absorbs a great amount
of radiant heat, thus, avoiding re-ignition and fire re-lapse.

Automatic Fire Extinguisher -BONPET

Automaticfire
extinguishing MobileExtinguishing Dilutionwithwater
How to use

TheBONPETfire extinguisherampoule'sautomaticactivation
Whathappens ifthe fire breaksoutin a closed areaprotectedby BONPET?
Due to fire the temperatureincreasesand as a resultofitthe extinguisher
liquidalso gets warmandexpandin the ampoule. When the temperatureof
theliquidgets 85C°+/-5C°itis convertedinto vapourand as a resultofthe
changingofthe liquidstatepressureisgenerated/created whichbreaksthe
glass into pieces.Thevapourspurts in the areastarting endotherm
processes whichtakeenergy/powerfrom the fire, thus dousing the fire
instantaneously
How it works
Please play the Video

Advantages of BONPET System
• High efficiency by extinguishing A, B, C and F types of fire
• 10 years warranty, No refilling cost
• Used as a Hand grenade
• The extinguishing liquid mixed with water can be used for Big Fires
• The installation is simple, necessary just 2 screws
• Work even in extreme weather conditions (from -23 C to 80 C) & operates reliably
• Takes up very little place

Advantages of BONPET System
• Doesn’t need to lay a cable, power supply or water pipe
• Doesn’t need any maintenance
• It can be used simply in case of panic situation
• The special glass of the ampoule, broken into pieces without edges
• It doesn't cause damage in electrical systems, machines
• Environment-friendly
• Non toxic effect on humans & other organisms

Comparisonofadvantagesordisadvantagesofthedifferentfireclasses:
A–Commonfire(solidflammablesubstances)
C–Flammablegas
B–Burningofflammableliquids(fuel)
F-Firemadeofvegetableoilandkitchenfat
“TheBonpetampouleworkswithgreatinsecurityinautomaticmodeofoperationbyextinguishing
ELECTRICALFIRES.ItisrecommendedtoinstallBonpetampoulesfor keepsafeandprotectelectrical
device,computercenters,transformersandelectricaldistributorsystems(till60000V.)”
HALONS AND
TYPEOFBURNINGMATERIAL BONPET WATER THEIR ABC
POWDER SUBSTITUES
A WoodenMaterial
Paper,Textil,Fabrics
Clothes,Bedlinen
Rubber,Celluloid
Hlastic
B
Petrol
FoodGreases
Other oils
F
vegetable oil,kitchenfat
verygood good bad good
verygood good bad good
verygood good bad good
verygood good bad good
verygood good good good
good bad good good
verygood bad good good
verygood bad good good
verygood bad good good
Comparison

Certifications -BONPET System

Emergency Fire Response Kit -Shield

Facilitatefightingfirefromadistanceofabout15–20feetindoor
SingleHandOperationandmulti-angledischargefacilitating
extinguishmentofceilingheightfires
OneextinguishertohandlemultipletypeoffirerisksuchasCookingOil
fire(ClassF)&LiveElectricalfire(classE),andClassA,BandC.
NoRe-ignitionoffireastheextinguishingagentformsathinfilmonthe
surface
MaintenanceFree
Biodegradable&negligibleresidualafteruse
4to6unitsofhand-heldfireextinguishersarepackagedinastrongbagto
facilitatecarryingittothefirespoteasily.
Hand Held Fire Extinguisher

Comparison between X-Fire Shield &
Conventional Extinguishers
Parameters X-Fire Shield Conventional Extinguishers
Proximity of fighting fire 20 to 25 feet 4to 7 feet
Ceiling Height Fire Can be used to extinguish
ceiling height fire
Cannot be used to fight ceiling height fire
Ease of operation & training Hand-held Operation with
minimum training
Both hand operation with intensive
training
Multiple threat points
capability
Possible Not possible
Class of Fire A,B,C,E and F A,B and C
Re-ignition Nil Possible
Maintenance Nil Periodic maintenance
Weight 700 gms 3kgs -5kgs
Equipment handling risk Nil Can cause severe damage to the user and
even fatality
Discharge time 30 seconds per Shield 8 seconds
Residue Negligible Noticeable

Certificates & Testimonials
Certifying Agency
TUV, Lloyds,
Underwriter’s Laboratories
Register for Shipping
National Emergency Directorate
Institute of Quality and Metrology
Ministry of Defense
Administration for Civil Protection and Disaster Relief
31

Monday, June 13, 2016 32
Application Areas
Segments Segments
IT Parks Warehousing
Shopping Malls Manufacturing
Colleges
SEZ’s
Hospitals Hotels

Emergency Fire Fighting System –Fire Trolley

Emergency Fire Fighting System (Fire Trolley)

•World’s first Battery OR Petrol Engine operated Emergency Fire Fighting System.
•Would replace 45 conventional extinguishers
•High pressure diaphragm pump with a flow rate of 25 liters per minute
•System capacity of 150 liters would provide 6 minutes of fire fighting equivalent to 45 conventional extinguishers
•Ideal for facilities without sprinkler or hydrant for Emergency Fire Response
•Can lance a distance of 40 feet as against 3 to 5 meters by conventional extinguisher
•Both jet type as well as mist type of spraying is available
•Trolley mounted provides mobility
•Equipment warranty of 5 years and Liquid performance warranty of 7 years
Details of Emergency Fire Fighting System –Fire Trolley

Automatic Fire Suppression Tubing System

Automatic
Fire
Suppression
Tubing
System

FireSuppressionSystemsprovideCost-Effective,Stand-Alone,
AutomaticFireSuppressionSystemsforyourCriticalEquipment,
Electrical/TechnicalSystemsandvarioustypesofenclosures.
TheeffectivenessofagenuineFiretraceSystem,happensbyutilizing
theproprietaryFiretraceDetectionTubing(aLinearPneumaticHeat
Sensor),whichdetectsafireduetoprecisetemperaturesensitivity,
allowingoursystemstoreactquicklyandeffectively.
Thisuniquedetectioncanberunthroughthesmallestormost
complexenclosurestoensuredetectionisalwaysclose athand.
Automatic Fire Suppression Tubing System

The heart of the system is the Linear Heat Sensitivepneumatic polymer tubing. It
is connected at one end to aExtinguishing Agent Container, which the rest runs
throughthe risk area, in a predetermined manner. When the flametouches the
tubing and it reaches a temperature of 67 Deg. C,the tubing bursts at it hottest
point (which is nearest to themost vulnerable part of the fire), thus forming a
nozzle .
The pneumatic mechanism then triggers the valve of the extinguisher & sprays
the agent out directly into the fire, thus dousing the fire quicker than any other
technique on the market.
This path breaking system, is entirely automatic, and once installed, requires no
human help. Thus making it the method of choice for “Localized environments”,
or areas which are cordoned off or have an enclosed area (such as panels,
servers..)
Automatic Fire Suppression Tubing System

DIRECTRELEASE SYSTEMS
Firetrace’sfire protection –direct release systems utilize the
tube as both the “detection device” and “suppressant delivery. As the fire
begins, the portion of the tube nearest the point where the most heat is
detected ruptures, forming an effective spray nozzle.
The pressure will then drop as the Firetrace tube releases the entire
contents of the cylinder through the distribution nozzle to effectively
suppress the fire. More than one Firetrace tube can be used enabling the
system to cover more area. Our fire suppression systems are critical for
safety and protecting your valuable equipments
Automatic Fire Suppression System operates on 2 different Techniques:
Direct & Indirect

INDIRECTRELEASE SYSTEMS
Once the tubing senses the fire, it ruptures –resulting in a drop of pressure causing the
Indirect Valveto activate
This diverts flow from the detection tube tothe larger outlet ports
Then the fire suppression system kicks in –theExtinguishing Agent is discharged from the
cylinderthrough the diffuser nozzles, flooding the area in aproprietary mix of fire
extinguishing chemicals,effectively suppressing the fire quickly &thoroughly
This system is typically used in larger areas that require ahigh volume of Extinguishing
Agents, to effectivelysuppress the fire
Multiple diffuser nozzles may be added to meet thespecific Application /requirements
Automatic Fire Suppression System operates on 2 different Techniques:
Direct & Indirect

Entirelyautomated , doesnotrequireany external powersupply, thusit functions
perfectlyin casean absenceofelectricity
Instantdetectionand instant suppression,without anyHuman involvement
Thesystemisalwaysreadyto respond.Hencethereisno downtime
UsesNovec1230,DuPontFE-36,NAFP IV, NAFS 125,HCFC123 and Co2
Flexibletubingallowsprotectionofareasthat wereotherwiseimpossibleto protect
Simpledesign.Thesystemgetsinstalledina fewhours,whichmeansminimallabour
and downtime
Ruggeddesignoffersoutdoorand indoorvariantsofthetube,and it canwithstand
harshconditionswhereothertypesofsystemsmight berenderedinadequate.
Advantages

Installations

Installations

Early Warning Liquid Leak Detection System

OurExpertiseandStrength
EarlyWarningLiquidLeakLocatingSystems
ELSA(EarlyLeakSystemApparatus)
Specializedin Liquid Leak Detectionand Locating Systems.
(Liquids=water,bases,acids)
OnlymanufacturertoofferASIC(ApplicationSpecificIntegratedComponent)
designsolutionwithuniquefeature –Fail-Safe LoopBack.
(Alsoknown asClassA Wiringwhichiscommonlyusefor FireAlarmsystem).
AllControl Panelshavea Sensitivityadjustment whichiseasilycontrol at siteto
thesensedifferentamountofliquidat sitesand to meet variousrequirement.
FlexibleandCustomizedSystemsolutiontailoredto individualneeds.
(eg:customlengthofsensingcable nowastage)
No compromiseinourServicesandProduct Quality.
WidecoverageSalesnetworkwithlocalofficesorpartnersinmajorcities.
Our Expertise and Strength
Early Warning Liquid Leak Locating System

3L-TP/12(12.1 Inch Touch Panel).
•Pin-PointLeakLocationprecisely,toleranceis +/1m.
3L-SP/DP(SupervisePanel): Monitorup to 99 unitsof 3L-AP/3L-DP/3L-NDP
•(3L-SP/DP+3L-AP/3L-DP/3L-NDP)Systemsableto monitor up to anaccumulated
SensingCablelengthof20Km(200m x 100units).
3L-AP: Advanced Locating Panel+ LCDdisplay
•2x Relays (Leak);1x Relay(CableBreak)
optional:(1) ModbusTCP/IP(2) RS485(3) 4~20mAanalogueoutput(192m)
•SensingCableLength–up to 200m permodule.
3L-DP: (Locating PanelinM36 DIN-RailorIP65)
•1x Relay(CommonAlarm)andRS485Communication.
•SensingCableLength–up to 200m per module.
•VisualAlarmbyLEDlightindicator.
•NOTE:3L-NDPaddressablemoduleavailableupon request.
3L-NP:(Non-Locating Panelin M36 DIN-RailorIP65)
•1xRelay(CommonAlarm)
•SensingCableLength–up to 60mper module.
•AlarmbyBuzzerand LEDlightindicator
Product at a Glance –Control Panel
Early Warning Liquid Leak Locating System

ProductataGlance–SensingCable
EarlyWarningLiquidLeakLocatingSystems
3L-LS:






Application:
Diametersize:
Continuitywires:
Sensingwires:
Carrier:
Fireresistance:
Waterand slightly-corrosiveconductiveliquids.
6mmaverage.
White&Red insulatedwith flame-retardantpolymer.
2xBlackwires,semi-conductivepolymer.
Flame-retardantpolymer material with greenishcolorin high visibility.
Non-flamepropagatingand self-extinguishing.
3L-AS:






Application:
Diametersize:
Highly-corrosiveconductiveliquidssuch as 100% SulfuricAcid.
6mmaverage.
Continuitywires:White&Red insulatedwith fire-resistantfluoropolymer.
Sensingwires:
Carrier:
Fireresistance:
2xBlackwires,semi-conductivefire-resistantfluoropolymer.
Fire-resistantfluoropolymermaterialwithyellowishcolorinhigh visibility.
UL910(NFPA262),highestFire/Smokestandard.
SensingCable andJoints
offer“Cutto Length”cablein Hot-ShrinktubeorMale/Femaleconnectors.
Ultrasensitivesensingcable (e.g.DewPointappln)availableupon request.
Product at a Glance –Sensing Cable
Early Warning Liquid Leak Locating System

3L-TP/12–12.1InchTouchPanel
EarlyWarningLiquidLeakLocatingSystems
Pin-PointLeakLocationPrecisely,tolerance+/-1m.
(indicationbyREDDOT).
History/EventLog:5,000events.
“Freezing”ofselectedzone(s)duringmaintenance/repair
andnofaultmessagegenerated.
ReadilyconnecttoGSMmodem/dialerfor SMSfaultnotification
Modbus/TCPoptionavailable.
AbilitytoZoom-Inontoeachfloorplan.
VariessizesofLCDmonitoravailableuponrequest.
3L-TP/12-12.1 inch Touch Panel
Early Warning Liquid Leak Locating System

3L-SP/DP–SupervisingPanel
EarlyWarningLiquidLeakLocatingSystems
•Monitorupto99units(external):
either3L-APor3L-DPor3L-NDP.
•Max.accumulatedlength:
sensingcableup to 20,000m(200m x100).
•LCDdisplay:
4linesEnglish characters.Each zoneis
programmablebysoftware(up to 35characters).


Event–Log(896time-stampedeventsstored)
Failed-SafeLoopBackFeature(class A wiringsystem):
Continueto detectleakifthereis acablebreak


Sensitivitycanbeadjustedmanually.
CommunicationinterfacewithBMS/EMS
2x Drycontactrelayforleaks
2x Drycontactrelayforcable-break
High Levelinterfaceprotocol :RS485/Modbus
3L-SP/DP –Supervising Panel
Early Warning Liquid Leak Locating System

3L-AP–LocatingPanel
EarlyWarningLiquidLeakLocatingSystems
3L-AP(LocatingPanelwithLCDdisplayc/wBacklight):
•Connectupto192m(4-20mA)or200m(RS485)of
sensingcableand300mofjumpercable.


PrecisionofLeakLocation:+/-1m
LCDdisplay–2x14 charactersto displayleaked
locationandcablebreak
•Continueto detectleakifthereisa cablebreak
Failed-SafeLoopBackFeature(classAwiringsystem).


Sensitivitycanbeadjustedmanually.
OptionalFeatures:



ModbusTCP/IP.
RS485/Modbus(OpenProtocol).
4-20mA AnalogOutput.
3xDry contactrelays:
2xleaksand1xcable-breaksignalsout
3L-AP –Locating Panel
Early Warning Liquid Leak Locating System

3L·LS-Sensor (S:) 3L·LS Senso CS2)
i i
~ ~
@
Red
SEN
@
n Bladt
ABLE
3L-AP: Sensingcable(S1,S2,… ,Sn)& Belden(8723) jumper(J1,J2,…,Jn)connection
withend termination.
Note: J1·• J2 1 •••• t-Jn~300 m
S1 +S2 -t-•••• t Sn <192
m
..
3LLS·Seruoi(Sn)
i
t
,~
Jumler Jn)\ JumJr(J2)
O@
White G~e
SING C

Uniquefeature–Fail-Safe
EarlyWarningLiquidLeakLocatingSystems
LoopBack
Fail-SafeLoopBackConnectionDiagram
Whenthereisacablebreak,thesensingcablewillbecutinto2separate
sections(S1a&S1b).
EitherS1a orS1bstillcancontinueto detectLiquidLeakage.
Unique Feature –Fail-Safe Loop Back
Early Warning Liquid Leak Locating System

3L-DP–LocatingModule
EarlyWarningLiquidLeakLocatingSystems
•Connectupto 200mofsensingcableand300mof
jumpercable.


PrecisionofLeakLocation:+/-1m
Continueto detectleakif thereisa cablebreak
Failed-SafeLoopBackFeature(classA wiringsystem).



RS485/Modbus(Openprotocol)
1xDry contactrelayoutputforleakorcable-break
Sensitivitycanbeadjustedeasilyatsite.
TypicalApplication:
•Connect3L-DP directly to3L-SP or
EMS/BMSwith sensingcables tomonitor
largeareasor multiplefloors.
3L-DP–Locating Module
Early Warning Liquid Leak Locating System

3L-NP–Non-LocatingModule
EarlyWarningLiquidLeakLocatingSystems



S1+S2+…+Sn<= 60m
J1+J2+…+ Jn<= 100m
Sensitivitycanbeadjustedmanually.
•1xDry contactrelay outputforleakorcable-break
TypicalApplication:
•To monitorsmallroomarea(typically20sqm)
whereleakcanbelocatedeasilysuchasPantryroom,
driptrays.
3L-NP –Non-Locating Module
Early Warning Liquid Leak Locating System

3L-NP–Non-LocatingModule
EarlyWarningLiquidLeakLocatingSystems
3L-NP –Non-Locating Module
Early Warning Liquid Leak Locating System

((
3L-SP
RcLAV
Typical Schematre Drawingusing ELSA3bSP+3L-DP+3L-APPanels
withCables
connection

Zone1: ServerRoom 1(Sensor =20m)
Zone2:Pantry Room1(Sensor =18m)
(_,
Belden cable
J
Zone3: CRAC 36-1 (Sensor= 25m)
Wall Mount

BoxIP65: 3L-DP

Zone4: FCU 36-3 (Sensor =Sm)
Interface 13L-SPl
1. Leak: Relay/DryContactx2pis.
2. CableBreak /Power Fail: Relay/Dry Contactx2pts,
3. High Level: RS48S/Modbus.
Interface13L-DPl
1. Leak/CableBreak/Power Fail: Relay/Dry Contactx1pt.
2. High Level : RS48S/Modbus.
3L-AP –Locating Panel
Early Warning Liquid Leak Locating System

(3L-TP/12+3L-SP/DP+3L-AP+3L-DP+3L-NDP)
system
LocatingSystems
ProjectSchematicDrawing
3L-TP/112 + 3L-SP/DP + 3L-DP + 3L -NDP
Early Warning Liquid Leak Locating System

(3L-TP/12+3L-SP/DP)system
EarlyWarningLiquidLeakLocatingSystems
3L-TP/12 + 3L-SP/DP) system
Early Warning Liquid Leak Locating System

AccessoriesParts
EarlyWarningLiquidLeakLocatingSystems
3L-T/L50:LabelingTag (Selfadhesive)–50pcsperstack
3L-HDC/2ST:Holddownclips(Selfadhesive)–100pcsperpack
3L-DS(04) :DistanceSpacer–4meterof“virtual”length
3L-Connectors: Male/Femaleconnectorpair
Wallmountenclosurefor3L-DPor3L-NDPor3L-NP:-IP 65 rating.
(Custommade enclosure boxare availableupon request)
Accessories
Early Warning Liquid Leak Locating System

3L-DS(DistanceSpacerorWeightedLength)
EconomicalSolutionfor monitoringafewZones
withjustoneControlmodules(ie:3L-APor 3L-DP)
Howitworks?
•A SpacerModuleactsasa distancespacer(eg:4 meter
spacing)to clearlysegregatetwo Zonesundermonitoring
by usingthismodule.
•EachZoneissegregatedby markingthedistancewith
theTag.
3L-DS (Distance Spacer or Weighted Length)
Early Warning Liquid Leak Locating System

FieldofApplications
EarlyWarningLiquidLekLocatingSystems



Data Centers,Computer/Server/IT RoomsforBanks,Financialcenters,
Logisticshubs& etc…
TelecommunicationSwitchingRoom
CleanRoomandLaboratorybuildin
•Semiconductor Plants
•LCDManufacturingPlants
•Wafer FabricationPlants
•Bio-Medical Plants





DistrictCooling/HeatingSystems,ACMV(CHILLEDWATER PIPING,
WaterTreatmentPlants
Undergroundhotwaterpiping
Tunnel
Library&Museum
CRAC,FCU)
Field of Applications
Early Warning Liquid Leak Locating System

InstallationatChemicalPlant
EarlyWarningLiquidLeakLocatingSystems
Installation at Chemical Plant
Early Warning Liquid Leak Locating System

InstallationatDataCentre
EarlyWarningLiquidLeakLocatingSystems
Installation at Data Center
Early Warning Liquid Leak Locating System

Sensing Cable –Chemical Pipeline
Early Warning Liquid Leak Locating System

Reference:Banking&Finance
EarlyWarningLiquidLeakLocatingSystems
Client’sName Country
Malaysia
Bangladesh
Malaysia
Singapore
HongKong
Singapore
HongKong
Bangladesh
Singapore
Singapore
Singapore
Bangladesh
Korea
Bangladesh
Malaysia
Singapore
Vietnam
HongKong
Singapore
HongKong
HongKong
HongKong
Korea
Singapore
Singapore
Singapore


























AllianceBank
Bank Asia
Bank NegaraMalaysia
Bank of America
Bank of ChinaInternational
Bank SwitzerlandInternational
BBVA(BancoBilbaoVizcayaArgentaria)
BRACBank
Citibank
DBS(DevelopmentBank of Singapore)
DeutscheBank
HabibBank
HyundaiSecurities
IFIC (Int’nalFinanceInvest & Commerce)
Kuwait Finance
MerrillLynch
NamABank
NewedgeGroup
NobleResources
Polaris Securities
PrudentialAssetManagement
SamsungSecurities
SeoulFinancialCenter
VTBCapital
Nomura
HSBC@MapletreeBusiness City
Reference: Banking & Finance
Early Warning Liquid Leak Locating System

Reference:DataCentreProviders,IT,Telco&Manufacturing
EarlyWarningLiquidLeakLocatingSystems
Client’sName Country
Singapore
HongKong
China
Indonesia
HongKong
Singapore
Singapore
Singapore
Singapore
Korea
Singapore
Singapore
Singapore
Taipei
China
Singapore
Singapore
Korea
Malaysia
Singapore
HongKong
Singapore
Singapore
Singapore
Singapore
Malaysia


























AppliedMaterials
AsiaTone(AST)
Beijing(AsiaPacific)Datacenter
CyberCSF
EricssonLimited
Equinix
GlaxoSmith Kline
GlobalSwitch
GroupSchneider(APCDatacenterShowRoom)
HyundaiSteelGroup
Intel-MicronFlash
JPMorgan
JurongDatacenter(JDD)
MXICWaferFabrication
KDDI
Pacnet
REC Solar
Samsung
Seagate
SingTel
Plant
SmarToneMobileCommunication
Silicon Laboratories
Starhub
SunMicrosystem
TataCommunicationExchange
TelecomMalaysia
Reference: Data Centre Providers, IT, Telco & Manufacturing
Early Warning Liquid Leak Locating System

Reference:Insurance,GovernmentBuildings&Others
EarlyWarningLiquidLeakLocatingSystems
Client’sName
•AIA

Country
Singapore
Singapore
Singapore
Singapore
Singapore
HongKong
HongKong
Singapore
Singapore
Singapore
HongKong
Singapore
Kuwait
Malaysia
China
Singapore
Brunei
Singapore
Malaysia
Singapore
Singapore
Singapore
Singapore
ChangiPrison





















ChangiAirport
ChangiWaterReclamationPlant(PUB)
Freeport
HongKongAirport
INGGroup
Lego
MarinaBay Sands(Casino&Resort)
MapleTreeAssetManagement
MayerBrownJSM (Johnson Stokes & Master)
Ministryof HomeAffair
Ministryof Water& Electricity
PadiniHoldings
(DistrictCoolingSystem)
PhoenixPublishing& MediaGroup (PPMG)
RioTinto
Shell
SingaporeDistrictCooling(SingaporePower)
SymphonyHouse
TemasekPolytechnic
TheSingaporeFreeport
ICAP@MBFC
BHPBiliton@MBFC
Reference: Insurance, Government Buildings & Others
Early Warning Liquid Leak Locating System

GEWINN Infra LLP
21, Asiatic Arcade,
Pokhran Road No. 01,
VartakNagar, Thane –400 606
Maharashtra, INDIA
Tags