About This Presentation

green house effect carbon information global warming , carbon calculation trading minimum


Slide Content

PT SELALU CINTA INDONESIA
GREENHOUSE GAS (GHG)
ISO 14064
AUGUST 22, 2024

AGENDA

COMPANY NAME PT. SELALU CINTA INDONESIA
Address
Jl. LingkarSelatan Salatiga, DsnTetepRt003/Rw003, Kel
Randuacir, KecArgomulyo, Salatiga–JawaTengah
Phone +62-298-343-2222
Type Of Business Footwear Manufacturing
Year Establishment 2016
Environmental DocumentsAMDAL
Production Capacity Shoes 240K/Week; Sandal 72K/Week
Workforce 18,500 Person
Energy Consumption 3,300 TOE (Not Mandatory for EnMS)
Total Area 30.65Ha
Certification ISO 50001:2018,ISO 14001:2015 , ISO 45001:2018
KMK GROUP PROFILE

Pasal 1, ayat 1 Pasal 1, ayat 1
Pasal 6, ayat 2 Pasal 6, ayat 2
Pasal 9 Pasal 9
Pasal 9 Pasal 9
LEGAL: Peraturan Presiden
No. 98 Th 2021

THE JOURNEY OF GHG INVENTORY
2016 2018 2020 2022 2023 2024 2025-2027 2030
•Starting of PT SCI
•1
st
NIKE Model Produced
•Mapping Energy & GHG
source
•Initial Energy & Carbon
Reporting
•Ramp Up of Production T2
•Design new Building & Equipment
with low Carbon Emission
•New Equipment Policy
•REC 50%
•Operation of Solar PV
•Technical Energy Audit
•Energy Minimum Program
•Real time Monitoring System
•REC 100%
•GHG Awareness Training
•Winner E & W Conservation
•Pilot Project IoTsystem
•GHG VnV
•ISO 50K Certified
•Phase 3 of Solar PV
•No Cost Energy Efficiency
•CASO
•CDP
•SBTi
•GHG 14064
•MCAP
•Phase out of LPG
•Reduce GHG
Emission for Scope
1&2 by 50%

MISSION
Optimize Energy Consumption, Advance Energy Management System & Sustainable Energy To
Achieve The Lowest Carbon Emission Company
GOAL
The Lowest Carbon Emission Company
PRIORITY
OPTIMIZE ENERGY CONSUMPTION &
RENEWABLE ENERGY
ADVANCE ENERGY MANAGEMENT
SYSTEM
ENERGY CULTURE
KEY INITIATIVE
ENERGY SKILL
DEVELOPMENT
ENERGY + CARBON
MANAGEMENT
SYSTEM
SOLAR PV
REC 100%
COMPRESSED AIR
OPTIMIZATION
MOTOR
MANAGEMENT
SYSTEM
ENERGY BY
MODEL
KEY ENABLERS
DATA & ANALYTIC
ISO 50001
ISO 14064
TEAM & TALENT
ENERGY CARBON STRATEGIC PLAN 2020-2025

Category 1 & 2 Reporting Data
SCOPE & BOUNDARIES

GM
Prod ENG RSM
HR HSE
HS ES EC
Manager
Energy
UH EC
Staff
EnMS (1)
Staff
EnMS (2)
Staff
Project
TEAM WORK & WORK TEAM

PROCEDURE & SOP

GA,ENG,GP,ES
Send activity data
EC Collect &
calculate data
emission
MR Review Data
Quality Data Checking
Consolidate KMK Group
GENERAL FLOWCHART GHG
DATA COLLECTION

1.1 Direct emissions from stationary combustion1.1 Direct emissions from stationary combustion
Electrical Generator
•Qty
•Consumption
•Location
•Bill/PO
•PIC
LPG for Canteen
•Qty
•Consumption
•Location
•Bill/PO
•PIC
Monthly Collecting data
& additional data
MAPPING & INVENTORY

Mobile Combustion
•Type of Fuels
•Consumption/Unit
•Bill
•Internal Transportation
•PIC
Monthly Collecting data
& additional data
1.2 Direct emissions from mobile combustion1.2 Direct emissions from mobile combustion
MAPPING & INVENTORY

WWTP Process
•Type Process
•Daily Collecting data
•Lab test (COD, BOD)
•PIC
Monthly Collecting data
& additional data
1.3 Direct process emissions and removals from industrial processes1.3 Direct process emissions and removals from industrial processes
MAPPING & INVENTORY

Refrigerant
•Type
•Daily Collecting data
•Method
•Bill/PO
•PIC
Monthly Collecting data
& additional data
1.3 Direct process emissions and removals from industrial processes1.3 Direct process emissions and removals from industrial processes
MAPPING & INVENTORY

Electricity
•Consumption
•Bill/PO
•PIC
Monthly Collecting data
& additional data
2.1 Indirect emissions from imported electricity2.1 Indirect emissions from imported electricity
MAPPING & INVENTORY

SCI’s Dashboard
POWER
METER
CONVERTE
R
Device from Circutor SCI DatabaseSCADA License
AUTOMATION
9 Production Building
15 Facilities Support
30 CTB Line
20 Bottom Line
117 Power meter
10 Converter
EMoS
2 Incoming
7 Trafo

Monthly Collecting data
& additional data
Monthly GHG data
& Group Consolidation
Report
CALCULATION & REPORTING

2020 2024
3.5 M
16.2 M
Production
Volume
THE GHG DATA

Category of Emission
Year
2020202120222023
Category 1
Diesel fuel Electric
Generator 39 48 3 7
LPG 59 62 63 61
Mobile combustion 91 104 156 179
Industrial Process (WWTP)17 13 76 133
Fugitive 21 17 16 52
Category 1
TOTAL 227 244 314 432
Category 2
Electrical 9,752 14,820 13,074 6,566
TOTAL EMISSION SCOPE 1&2
9,979 15,064 13,388 6,998
REMARK
51%34%
-
30%
Absolute GHG Reduction
30%
from 2020 Baseline*
THE GHG DATA

The Validation & Verification Report
August 20-21 2024
VB : BBSKKP & Kemenperin
VERIFICATION & VALIDATION

THE MITIGATION ACTION PLAN

SateliteSewing & Presewing (0.5 MW
AC)
*Energy= 952 MWH / YEAR
*Carbon= 735 TON CO2 / YEAR
Install Cap
5.04
MWP
Equal
: 3.9
MW
Permit
1.4
MW
36%
Technical Building T2 (0.9 MW AC)
*Energy= 1,645 MWH / YEAR
*Carbon= 1,270 TON CO2 /
YEAR
Production Building T2 &
Laminating T2 (2.5 MW AC)
*
Energy = 4,546 MWH / YEAR
*Carbon = 3,509 TON CO2 / YEAR
Planning Operation Oct 2024
Progress :
-Permit with PLN
E
nergy
:
2.59
GWh/Year
C
arbon
:
2.00
Kilo
Ton
??????
/Year
On Progress for
Operation

Total CarbonReduction
48.84 Kilo Ton CO
??????
Renewable Energy
Certificate
Total CarbonReduction
374.12 Ton CO
2
/Year
E-trans
Total CarbonReduction
2.7 Ton CO
2
/Year
Solar PV Facility
Total CarbonReduction
424Ton CO
2
/Year
Energy Efficiency
No/Low Cost Investment
Optimized Control Chamber
Optimized Control Chiller
Installing motion sensor at toilet
SUSTAINABILITY

2 Group
1.Factory Tour by Bus
2.Sky bridge Production
SITE VISIT