Highland Tanks are constructed to
one or more of these specifications:
•UL-58, UL-1746, UL-142, UL-2085, UL-2080,
UL-2215, UL-1D42
•Steel Tank Institute (STI)
•Southwest Research Institute (SRI)
•American Petroleum Institute (API)
•Plumbing & Drainage Institute (PDI)
VERTICAL STORAGE TANKS AT BULK PLANT
Horizontal Tank
Construction
Single-wall Double-wall
Highland Tank
Oil/Water Separators
EPA Regulations:
NPDES – National Pollutant Discharge
Elimination System (Phase I & II)
SPCC – Spill Prevention Control and
Countermeasure
Sewer Pretreatment Regulations
Highland Tank
Oil/Water Separators
•Vehicle Services associated with these
facilities include:
·Fueling/Dispensing Areas
·Repair and Maintenance Shops
·Wash Areas
Highland Tank
Oil/Water Separators
How Oil Appears in Water:
•Free Oil
•Oily-coated Solids
•Physical Emulsions
•Chemical Emulsions
•Dissolved Oil
HTC-20000 AG INSTALLED AT
NEW
WORLD TRADE CENTER NO. 7
Rectangular
Oil/Water Separators
RHTC-300 INSTALLED AT
STATE POLICE BARRACKS
BLOOMFIELD, NJ
RHTC-20,000 OWS INSTALLED AT
DFSP, CRANEY ISLAND, PORTSMOUTH, VA
R-HTC-1000 INSTALLED AT
EXXON/MOBIL BAYONNE, NJ
RHT/RHTC Rectangular
Oil/Water Separator
Removable Top Cover
Lifting Handle
WIDTH
HEIGHT
Oil Dam
LENGTH
Parallel Corrugated
Plate Coalescer
INLET
OUTLET
Effluent
Transfer Pipes
Lifting
Lugs
Velocity Head
Diffusion Baffle
Optional
Sludge
Hopper
Optional
Support
Legs
PETRO-SCREEN
TM
Coalescer
Denver Internation Airport
50,000 Gallon OWS
Deep Sump Basin
Influent Pumping
System
RHTC OIL/WATER SEPARATOR
WITH DEEP SUMP BASIN
DSB SHOWING FACTORY INSTALLED
PNEUMATIC PUMP AND SENSOR
Sand/Oil Interceptors
MANUAL OIL AND GREASE INTERCEPTORS
MANUAL OIL AND GREASE INTERCEPTORS
(2) TB-10,000 FOR
NATIONAL
AUTO TRUCKSTOPS
COLUMBUS, OH
Highland Tank
Oil/Water Separators
Oil/Water Separator Sizing
•Outdoor-storm water runoff: Q (gal/min) = AREA
(sq.ft.) x RAINFALL x 0.0104
•Indoor-service bay drainage: Q (gal/min) = AREA
(sq.ft.) x 0.00748
•Check that the separator has the capacity to
adequately intercept and collect the largest spill
projected at the facility. If not, increase the volume
of the separator accordingly.
(2) 25,000 INTERCEPTOR/50,000 OWS
STORMWATER MANAGEMENT SYSTEM AT
UPS, ROCKFORD AIRPORT, IL
Advanced Secondary
Treatment Systems
ASTS
(Advanced Secondary Treatment Systems)
•What is the ASTS?
ACTIVATED CLAY OR CARBON ASTS
CRUDE OIL PRODUCTION WELL
WASTEWATER TREATMENT WITH
OWS/ASTS CASPER, WY
Advanced
Filtration Systems
AFS
(Advanced Filtration Systems)
AFS ADVANCED FILTRATION SYSTEMS
ASFS
OWS WITH AFS DEWATERING THE RANGER
AT
THE PHILADELPHIA NAVAL BASE
ASFS
OWS WITH AFS DEWATERING THE RANGER
AT
THE PHILADELPHIA NAVAL BASE
ASFS
R-HTC OWS WITH AFS AT
GENERAL ELECTRIC POWER PLANT
Underground
Steel Storage Tank
Product Information
VERTICAL STORAGE TANKS AT BULK PLANT
HIGHGUARD™ TANK
INSTALLATION AT SHEETZ CONVIENCE STORE
HIGHGUARD™ COMPOSITE TANK
VERTICAL STORAGE TANKS AT BULK PLANT
HIGHGUARD™ COMPOSITE TANK
ACT-100-U
®
Composite
Steel Storage Tanks
•70 mil thick dielectric coating
•UL-58 and UL-1746 Approved
•30-year Warranty
ACT-100-U INSTALLATION AT
GASOLINE SERVICE STATION
SOMERSET, PA
UST BULK PLANT WITH ACT-100-U TANKS
STI-P3
®
Cathodically Protected Steel Storage
Tanks
•Three forms of protection
- Dielectric coating
- Electrical isolation
- Sacrificial anodes
•UL-58 and UL-1746 Approved
•30-year Warranty
(5) 50,000 GALLON FUEL STORAGE TANKS
FOR DUAL FUEL POWER FACILITY
PRINCETON UNIVERSITY, NJ
15 MIL POLYURETHANE COATING
OVER GRIT BLAST
NYLON DIELECTRIC BUSHINGS AND/OR FLANGE KITS
PREENGINEERED CATHODIC PROTECTION WITH
ZINC/MAGNESIUM SACRIFICIAL ANODES
TITAN
®
Jacketed Tanks
•High molecular weight thermoplastic outer
tank is vacuum sealed around the steel inner
tank.
•Virtually damage proof outer tank
•UL-58 and UL-1746 Approved
•30-year Warranty