hyphenatedtechniques-200429145545.pdf

149 views 47 slides Jul 24, 2023
Slide 1
Slide 1 of 47
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47

About This Presentation

LCMS


Slide Content

Contents
1.Introduction
2.List of Hyphenated Techniques
3.GC-MS
4.LC-MS
5.GC-IR
6.LC-ESI-MS
7.Advantages of Hyphenated Techniques
8.References
2

What Is Hyphenated Technique ?
(1)
The term “hyphenation” was first adapted by Hirschfeld in
1980.
The technique developed from the coupling of a separation
technique and an on-line spectroscopic detection technology
is known as hyphenated technique.
3
Introduction

Hyphenated techniques ranges from
combination of –
1. Separation-separation
2. Separation-identification &
3. Identification- identification techniques
Introduction conti….
4

1. GC-MS
2. LC-MS
3. LC-NMR
4. EC-MS
5. CE-MS
6. GC-IR
7. LC-ESI-MS
8. LC-MS-MS
9. GC-MS-MS
10. GC-GC-MS
11. GC-NMR
12. HPLC-DAD-MS
13. HPLC-DAD-NMR-MS
5
List of Hyphenated
Techniques

Gas
Chromatography
Mass
Spectroscopy
GC-MS
• Invented By James & Martin in 1952
6
GC-MS

Principles :
GC :
• May be Gas Liquid [GLC] or Gas Solid Chromatography [GSC]
but GLC is preferred
• GLC works by partition but GSC works by adsorption
• In GLC the substance to be studied first converted to gas which
works as the mobile phase.

MS :
1. Ion Formation
2. Ion Separation & Detection
7
GC-MS conti….

• Techniques used to form ions are:
1. Electron Ionisation
2. Chemical Ionisation
3. Desorption Ionisation
i. Secondary Ion Mass Spectroscopy [SIMS]
ii. Fast Atom Bombardment [FAB]
iii. Matrix Associated Laser Desorption
Ionisation [MALDI]
4. Electrospray Ionisation
8
1.Ion Formation
GC-MS conti….

2.Ion Separation and Detection
• Types of instruments are used:
i. Direct Focusing Type:
a) Single Focusing
b) Double Focusing
ii. Quadruple Mass Analyser
iii. Quadruple Mass Storage
iv. Time of Flight Mass Analyser
9
GC-MS conti….

Instrumentation of GC :
A. Carrier Gas:
• Chemically inert
• Suitable for the detector use
• Amount of impurity should be less
• Easily available and should be cheap
• Non inflammable

Generally used carrier gases are
He, H, N, Ar etc.
10
GC-MS conti….

B. Flow Regulators:
Used to maintain the
uniform pressure and
flow rate.

Generally used are:
• Rotameter
• Soap Bubble Flow Meter
11
GC-MS conti….

C. Injection Devices:
• GAS : Valve Devices
• LIQUID : Loop Devices
• SOLID : Dissolve the
substance in suitable
solvent and then inject.
12
GC-MS conti….

D. Columns:
Columns can be of the following types:
• Packed Columns [Stationary Phase- PEG]
• Open Tubular Column or Open Capillary Column/ GOLAY Column
• SCOT ( Support Coated Open Tubular Column)
13
GC-MS conti….

E. Temperature Controlling Devices:
The devices are very important role playing.
Generally used Temperature Controlling Devices are:
• Pre heaters(for vapour formation)
• Thermostatically controlled oven
14
GC-MS conti….

Instrumentation of MS :
15
GC-MS conti….

Principle of working and interfaces :
GC-MS works by :
1. Iso Thermal Principle
2. Liner Principle


Interfaces of GC MS are :
1. Molecular Separator
2. Permeation Separator
3. Open Split
4. Capillary Direct
16
GC-MS conti….

Problem
Bank President

Who robbed the bank ?
17
Biologists

What protein was
isolated ?
GC-MS conti….

Gather Evidence
18
Police Officer

1.Interview witness
2.Dust for fingerprints
Mass Spectrometrist
1.Interview biologists who
isolated the protein
2.Cleave protein to obtain
peptide mixture


3.Analyse peptide mixture by MS
to obtain Peptide molecular
masses !
GC-MS conti….

19
Database Search Results
Police Officer

Identifies the robber

Mr. XYZ
Mass Spectrometrist

Identifies the protein

e.g. bovine carbonic
anhydrase
GC-MS conti….

Applications of GC-MS :
(1)
Elucidation of the structure of organic & biological
molecules.
Impurity profiling of pharmaceuticals.
Identification of components in thin layer & paper
chromatograms.
Identification of drugs of abuse & metabolites of drugs of
abuse in blood, urine & saliva.
20
GC-MS conti….

Sports antidoping analysis (in forensic GC-MS).
Analyzer of aerosol particles.
Determination of pesticide residues in food.
Polymer characterization (pyrolysis methods combined
GCMS).
Drug monitoring & toxicology studies.
Explosive analysis
Environmental analysis
21
GC-MS conti….

22
LC-MS

Liquid
Chromatography
Mass
Spectroscopy
LC-MS

Components of LC-MS :
HPLC
Ion
source
Mass
analyser
Detector
23
LC-MS conti….

HPLC :
•Non polar S.P. like C8 column, C18
column phenyl-bonded silica
Stationary
phase
•Water, Acetonitrile, Methanol etc. Mobile phase
•Length : 150mm(large column),
50mm (short column),
•Internal diameter : 2mm – 4.6mm
Column
•0.05 to 0.2 ml/min Flow rate
24
LC-MS conti….

Mass Spectroscopy :
(5,6)
Ionization
chambers
Mass
analysers
Detectors
25
LC-MS conti….

Ionization and Interface :
Electrospray Ionization (ESI)
Atmospheric Pressure Chemical Ionization (APCI)
Thermo Spray Ionization (TSI)
Atmospheric Pressure Photo Ionization(APPI)
Particle Beam Ionization
26
LC-MS conti….

Acceleration Ionisation
27
LC-MS conti….

28
LC-MS conti….
Electrospray Ionization (ESI) :

29
LC-MS conti….
Atmospheric Pressure Chemical Ionization (APCI) :

30
LC-MS conti….
Atmospheric Pressure
Photo Ionization (APPI) :
Thermo Spray
Ionization (TSI)

Mass Analysers :
Quadrapole Analyser
Time of Flight Analyser
Ion Trap Analysers
Fourier Transform-Ion Cyclotron Resonance
analyser (FT-ICR)
31
LC-MS conti….

Quadrapole Analyser
32
LC-MS conti….

Ion Trap Analyser
33
LC-MS conti….
Time of Flight
Analyser

Fourier Transform-Ion Cyclotron
Resonance analyser (FT-ICR)
34
LC-MS conti….

Detectors :
Records either the charge induced or the current produced
when an ion passes by or hits a surface.
A continuous dynode particle
multiplier detector
35
LC-MS conti….

Faraday Cup Detector
36
LC-MS conti….

Detection
37
LC-MS conti….

Mass spectrum of chemical compounds
38
LC-MS conti….

Pharmacokinetics: Bio analysis
Drug development
Molecular weight determination
Toxicology
Impurity detection
Determination of isotopes
Proteomics/Metabolomics
Determination of pesticides, herbicides & organic
pollutants for environmental ,monitoring.
Applications of LC-MS :
(1)
39
LC-MS conti….

Comparison of LC-MS with GC-MS :
•GC-MS requires compounds to be volatile to be ionised.
- traditionally electron impact source is used.
•LC-MS can be used to detect compounds from poly-
aromatic (non-polar) to peptide & proteins.
•GC-MS is still able to detect long chain aliphatic
compounds (petroleum based analytes) & very low mass
volatile material better than LC-MS.
40

Very sensitive, very expensive, sample recovery is also
possible because IR is non-destructive technique.
In this, GC does the separation part where as IR perform
function of identification.
Effluent from GC is directly forwarded into the heated
pipe of IR at atmospheric pressure.
IR spectroscopy identifies the compound by identifying
the functional group.
41
GC-IR

Gas
Chromatography
Infrared
Spectroscopy
GC-IR

42
Applications of GC-IR :
DNA analysis of blood samples, other fluids.
Pharmaceutical applications
Industrial applications
GC-IR conti….

43
LC-ESI-MS

44
Principle :
LC-ESI-MS conti….

1. Fast and accurate analysis.
2. Higher degree of automation.
3. Higher sample throughput.
4. Better reproducibility.
5. Reduction of contamination due to its closed system.
6. Separation and quantification achieved at same time.
45
Advantages of
Hyphenated Techniques:

1.Kalpesh N Patel, et al ; Introduction to hyphenated techniques and their
applications in Pharmacy; Pharmaceutical Methods; Oct-Dec 2010; Vol 1 ;
Issue 1.
2.Silverstein R; Spectroscopic Identification of Organic Compounds; Wiley
Publication Delhi; 6
th
edition; 2009; Page 2-70
3.Skoog D et al; Fundamentals of Analytical Chemistry; Cengage Brain
Publication London; 9
th
edition; 2010; Page 16-25.
4.AH Beckett, J.B Stenlake, Pharmaceutical chemistry;4
th
edition-Part
2;Page 474-477.
5.Gurdeep R. Chatwal, K. Anand; Instrumental methods of chemical
analysis; Page 2.272,2.673
6.G. C. Stafford et al.; International Journal of Mass Spectrometry and Ion
Processes, 60; 1984, Page 85 and Analytical Chemistry, 59; 1987, Page
1677.
7.https://www.jic.ac.uk/services/metabolomics/topics/lcms/why.htm

46
References
Tags