Iabp instrumentation, indications and complications

1,886 views 86 slides Feb 17, 2018
Slide 1
Slide 1 of 86
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53
Slide 54
54
Slide 55
55
Slide 56
56
Slide 57
57
Slide 58
58
Slide 59
59
Slide 60
60
Slide 61
61
Slide 62
62
Slide 63
63
Slide 64
64
Slide 65
65
Slide 66
66
Slide 67
67
Slide 68
68
Slide 69
69
Slide 70
70
Slide 71
71
Slide 72
72
Slide 73
73
Slide 74
74
Slide 75
75
Slide 76
76
Slide 77
77
Slide 78
78
Slide 79
79
Slide 80
80
Slide 81
81
Slide 82
82
Slide 83
83
Slide 84
84
Slide 85
85
Slide 86
86

About This Presentation

IABP


Slide Content

IABP- Instrumentation , Indications and Complications

2 Intra aortic balloon counter pulsation( IABP): Most common and widely available methods of mechanical circulatory support Temporary support for the left ventricle by mechanically displacing blood within the aorta Concepts: - Systolic unloading - Diastolic augmentation Traditionally used in surgical and non surgical patients with cardiogenic shock

3

4 Indications for IABP 1. Cardiogenic shock : 2. In association with CABG : Preoperative insertion - Patients with severe LV dysfunction - Patients with intractable ischemic arrhythmias Postoperative insertion - Postcardiotomy cardiogenic shock - Associated with acute MI - Mechanical complications of MI - MR , VSD 3. In association with nonsurgical revascularization: Hemodynamically unstable infarct patients High risk coronary interventions - severe LV dysfunction, LMCA, complex coronary artery disease 4. Stabilization of cardiac transplant recipient before insertion of VAD Post infarction angina Ventricular arrhythmias relathed to ischemia

5

6 Contraindications to IABP Severe aortic insufficiency Aortic aneurysm Aortic dissection Limb ischemia Thrombo embolism

7

8 LV contraction : - Isovol. Contraction (b) - maximal ejection (c) LV relaxation: - start of relaxation and reduced ejection (d) - isovol.relaxation (e) LV filling: - LV filling , rapid phase (f) - slow LV filling (g) - atrial systole( a) Cardiac cycle

9

10

11

12

13

14 Interpreting IABP waveforms

15 IABP –instrumentation and techniques

16 The IAB Counter pulsation system - two principal parts A flexible catheter -2 lumen first - for distal aspiration/flushing or pressure monitoring second - for the periodic delivery and removal of helium gas to a closed balloon. A mobile console system for helium transfer computer for control of the inflation and deflation cycle

17

18 HEMODYNAMIC EFFECTS — Inflation and deflation of the balloon Blood is displaced to the proximal aorta by inflation during diastole. Aortic volume ( afterload ) is reduced during systole through a vacuum effect created by rapid balloon deflation

19 Expected changes with IABP support in hemodynamic profile in patients with Cardiogenic shock - Decrease in SBP by 20 % I ncrease in aortic Diastolic Press. by 30 % ( raise coronary blood flow) I ncrease in MAP R eduction of the HR by 20% D ecrease in the mean PCWP by 20 % - El evation in the COP by 20%

20

21 IABP catheter: 10-20 cm long polyurethane bladder 25cc to 50cc capacity Optimal 85% of aorta occluded (not 100%) The shaft of the balloon catheter contains 2 lumens: - one allows for gas exchange from console to balloon - second lumen - for catheter delivery over a guide wire - for monitoring of central aortic pressure after installation.

22 Intra Aortic Balloon

23 IABP sizing chart

24 Benefits of larger volume IABs 􀁑 More blood volume displacement 􀁑 More diastolic augmentation 􀁑 More systolic unloading

25 Introducer needle • Guide wire • Vessel dilators • Sheath • IABP (34 or 40cc) • Gas tubing • 60-mL syringe • Three-way stopcock IABP Kit Contents

26 Intraaortic balloon

27 Connect ECG Set up pressure lines Femoral access – followed by insertion of the supplied sheath(7.5 F) 0.030 inch supplied J-shaped guide wire to the level of the aortic arch (LAO view) STEP BY STEP- IABP insertion

28 Before taking the Catheter out of Tray

29 Take the entire catheter and T handle as one unit (DO NOT disconnect one-way valve when removing the extracorporeal tubing from the tray.) Pull out the T- handle only as shown

30 • Remove stylet/aspirate/Flush • Insert the balloon only over the guide wire • Hold the catheter close to skin insertion point • Advance in small steps of 1 to 2 cm at a time and stop if any resistance. • The IABP should advance freely Inserting the Balloon catheter Many vascular complications occur during insertion itself Resistance during insertion either indicates PVOD, or dissection - Kinking of IABP » improper inflation/deflation

31 The end of the balloon should be just distal (1-2 cm) to the takeoff of the left subclavian artery - Position should be confirmed by fluoroscopy or chest x-ray Positioning

32 Connecting to console: - Connect helium gas tube to the console via a long extender Open helium tank. The central lumen of the catheter is flushed and connected to pressure tubing with 3 way and then to a pressure transducer to allow for monitoring of central aortic pressure. - Zero the transducer Initial set-up: - Once connected properly the console would show ECG and pressure waveforms. - Check Basal mean pressure - Make sure the setting is at “auto” - Usually IABP started at 1:1 or 1:2 augmentation - Usually Augmentation is kept at maxim

33

34 Trigger modes Trigger : - Event the pump uses to identify the onset of cardiac cycle (systole) - Pump must have consistent trigger in order to provide patient assist - If selected trigger not detected, counter pulsation will interrupted 1.ECG - uses the slope of QR segment to detect triggering point 2. AP(Arterial pressure wave) - Systolic upstroke of the arterial pressure wave form is the trigger 3. IN(Internal trigger)

35 ECG signal – most common • Inflation - middle of T wave • Deflation – peak of R wave • Pacer (v/a) • Arterial waveform • An intrinsic pump rate (VF, CPB)

36 Auto Operation Mode  Automatic lead and trigger selection  Automatic and continuous inflation and deflation timing management - User has ability to fine-tune deflation timing  Automatic management of irregular rhythms Semi-Auto Operation Mode  Operator selects most appropriate lead and trigger source Initial settings

37

38

39

40

41 Increased coronary perfusion The “normal” augmented waveform

42 Not all Sub optimal augmentation is due to Timing errors/kinks

43 Factors affecting diastolic augmentation Patient - Heart rate - Mean arterial pressure - Stroke volume - Systemic vascular resistance Intra aortic balloon catheter - IAB in sheath - IAB not unfolded - IAB position - Kink in the IAB catheter - IAB leak - Low helium concentration Intra aortic balloon pump - Timing - Position of IAB augmentation control

44 How to check waveform is acceptable ? First change from 1:1 to 1:2 augmentation

45

46 How to check waveform is acceptable ? First change from 1:1 to 1:2 augmentation Check the dicrotic notch See if augmentation starts at that point This should produce a sharp “V” at inflation.

47 How to check waveform is acceptable ? First change from 1:1 to 1:2 augmentation Check the dicrotic notch See if augmentation starts at that point This should produce a sharp “V” at inflation. Check if diastolic augmented wave is › systolic wave

48 How to check waveform is acceptable ? First change from 1:1 to 1:2 augmentation Check the dicrotic notch See if augmentation starts at that point This should produce a sharp “V” at inflation. Check if diastolic augmented wave is › systolic wave Confirm if end diastolic wave following the augmented wave is less than an non augmented wave. Is Deflation slope ok

49

50 Late Inflation Inflation of the IAB markedly after closure of the aortic valve. Waveform Characteristics: • Inflation of IAB after the dicrotic notch. • Absence of sharp V. Sub optimal diastolic augmentation

51 Early Deflation Premature deflation of the IAB during the diastolic phase.

52 Late Deflation Late deflation of the IAB during the diastolic phase. Waveform Characteristics: • Assisted aortic end diastolic pressure may be equal to the unassisted aortic end diastolic pressure. • Rate of rise of assisted systole is prolonged. • Diastolic augmentation may appear widened

53 Once Arterial waveform is ok, check balloon waveform Normal Balloon Pressure Waveform

54

55 Variation in balloon pressure wave forms Increased duration of plateau due to longer diastolic phase Decreased duration of plateau due to shortened diastolic phase

56 Variation in balloon pressure wave forms Varying R-R intervals result in irregular plateau durations

57 Variation in balloon pressure wave forms Increased height or amplitude of the waveform Decreased height or amplitude of the waveform

58 Variation in balloon pressure wave forms Gas leak Leak in the closed system causing the balloon pressure waveform to fall below zero baseline.. due to a loose connection a leak in the IAB catheter - H2O condensation in the external tubing a patient who is tachycardiac and febrile which causes increased gas diffusion through the IAB membrane

59 Catheter Kink Rounded balloon pressure waveform - Loss of plateau resulting from a kink or obstruction of shuttle gas - Kink in the catheter tubing Improper IAB catheter position Sheath not being pulled back to allow inflation of the IAB - IAB is too large for the aorta IAB is not fully unwrapped H2O condensation in the external tubing

60 “Balloon too large” syndrome

61 Patient Management During IABP support Anticoagulation-- maintain apTT at 50 to 70 seconds CXR daily – to R/O IAB migration Check lower limb pulses - 2 hourly. - If not palpable » ? - vascular obstruction - thrombus, embolus, or dissection (urgent surgical consultation) Prophylactic antibiotics --?? Hip flexion is restricted, and the head of the bed should not be elevated beyond 30°.

62 Never leave in standby by mode for more than 20 minutes > thrombus formation Daily – Haemoglobin (risk of bleeding or haemolysis) – Platelet count (risk of thrombocytopenia) – Renal function (risk of acute kidney injury secondary to distal migration of IABP catheter) Wean off the IABP as early as possible as longer duration is associated with higher incidence of limb complications Patient Management During IABP support

63

64 Weaning of IABP Timing of weaning: - Patient should be stable for 12 – 24 hours - Decrease inotropic support - Decrease pump ratio – From 1:1 to 1:2 or 1:3 - Decrease augmentation - Monitor patient closely – If patient becomes unstable, weaning should be immediately discontinued

65 IABP Removal Discontinue heparin 1 hour prior to removal Disconnect the IAB catheter from the IAB pump - Patient blood pressure will collapse the balloon membrane for withdrawal - Withdraw the IAB catheter through the introducer sheath until resistance is met. NEVER attempt to withdraw the balloon membrane through the introducer sheath. Remove the IAB catheter and the introducer sheath as a unit - Check for adequacy of limb perfusion after hemostasis is achieved.

66 Thank you

1. Major physiological effects of counter pulsation include? A) increased coronary artery perfusion, increased preload, decreased after load, decreased myocardial oxygen consumption B) increased coronary artery perfusion, increased preload, increased after load, decreased myocardial oxygen consumption C) increased coronary artery perfusion, decreased preload, decreased after load, increased myocardial oxygen consumption D) increased coronary artery perfusion, decreased preload, decreased after load, decreased myocardial oxygen consumption 67

2. the dicrotic notch on the arterial wave form reflects A) aortic valve opening B) aortic valve closure C) isovolumetric contraction D)rapid ejection 68

3. Expected changes with IABP support in hemodynamic profile in patients with Cardiogenic shock include all except? A) Decrease in SBP by 20 % B) Increase in aortic DP by 30 % C) Decrease in MAP by 10% D) Reduction of the HR by 20% E)Decrease in the mean PCWP by 20 % 69

4. late inflation of the balloon can result in? premature augmentation increased augmentation C) decreased augmentation D) increased coronary perfusion 70

5. A rounded balloon pressure wave form indicate? A) helium leak B) power failure C) hypovolemia D) balloon occluding the aorta 71

6. width of balloon pressure wave form corresponds to A) length of systole B) length of diastole C) arterial pressure D) helium level 72

7. true statement Dicrotic notch- land mark used to set deflation Deflation is timed to occur during period of iso volumetric contraction Most common trigger used is arterial pressure wave method Internal trigger mode is acceptable to use in a patient with normal sinus rhythm 73

8. true statement A) pacing spikes are automatically rejected in ECG triggered modes B) pacing trigger modes can be used in a patient of 50% paced rhythm C) Varying R-R interval result in regular plateau durations in Balloon pressureWave form 74

9. Identify the tracing abnormality 75

10. Identify the tracing abnormality 76

1. Major physiological effects of counter pulsation include? A) increased coronary artery perfusion, increased preload, decreased after load, decreased myocardial oxygen consumption B) increased coronary artery perfusion, increased preload, increased after load, decreased myocardial oxygen consumption C) increased coronary artery perfusion, decreased preload, decreased after load, increased myocardial oxygen consumption D) increased coronary artery perfusion, decreased preload, decreased after load, decreased myocardial oxygen consumption 77

2. the dicrotic notch on the arterial wave form reflects A) aortic valve opening B) aortic valve closure C) isovolumetric contraction D)rapid ejection 78

3. Expected changes with IABP support in hemodynamic profile in patients with Cardiogenic shock include all except? A) Decrease in SBP by 20 % B) Increase in aortic DP by 30 % C) Decrease in MAP by 10% D) Reduction of the HR by 20% E)Decrease in the mean PCWP by 20 % 79

4. late inflation of the balloon can result in? A) premature augmentation B) increased augmentation C ) decreased augmentation D) increased coronary perfusion 80

5. A rounded balloon pressure wave form indicate? A) helium leak B) power failure C) hypovolemia D) balloon occluding the aorta 81

6. width of balloon pressure wave form corresponds to A) length of systole B) length of diastole C) arterial pressure D) helium level 82

7. true statement Dicrotic notch- land mark used to set deflation Deflation is timed to occur during period of iso volumetric contraction Most common trigger used is arterial pressure wave method Internal trigger mode is acceptable to use in a patient with normal sinus rhythm 83

8. true statement A) pacing spikes are automatically rejected in ECG triggered modes B) pacing trigger modes can be used in a patient of 50% paced rhyth C) Varying R-R interval result in regular plateau durations in Balloon press. Wave form 84

9. 85

10. 86
Tags