IEC CODES.pdf

felix898002 532 views 7 slides Nov 21, 2023
Slide 1
Slide 1 of 7
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7

About This Presentation

iec codes


Slide Content

IEC 60038IEC standard voltagesIEC 60051 seriesDirect acting indicating analogue electrical measuring instruments and their accessoriesIEC 60071-1Insulation co-ordination - Definitions, principles and rulesIEC 60076-1Power transformers - GeneralIEC 60076-2Power transformers - Temperature rise for liquid immersed transformersIEC 60076-3Power transformers - Insulation levels, dielectric tests and external clearances in airIEC 60076-5Power transformers - Ability to withstand short-circuitIEC 60076-7Power transformers - Loading guide for oil-immersed power transformersIEC 60076-10Power transformers - Determination of sound levelsIEC 60076-11Power transformers - Dry-type transformersIEC 60076-12Power transformers - Loading guide for Dry-type power transformersIEC 60146-1-1Semiconductor converters - General requirements and line commutated converters - Specifications of basic requirementsIEC 60255-1Measuring relays and protection equipment - Common requirementsIEC 60269-1Low-voltage fuses - General requirementsIEC 60269-2Low-voltage fuses - Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to KIEC 60282-1High-voltage fuses - Current-limiting fusesIEC 60287-1-1Electric cables - Calculation of the current rating - Current rating equations (100% load factor) and calculation of losses - GeneralIEC 60364-1Low-voltage electrical installations - Fundamental principles, assessment of general characteristics, definitionsIEC 60364-4-41Low-voltage electrical installations - Protection for safety - Protection against

electric shockIEC 60364-4-42Low-voltage electrical installations - Protection for safety - Protection against thermal effectsIEC 60364-4-43Low-voltage electrical installations - Protection for safety - Protection against overcurrentIEC 60364-4-44Low-voltage electrical installations - Protection for safety - Protection against voltage disturbances and electromagnetic disturbancesIEC 60364-5-51Low-voltage electrical installations - Selection and erection of electrical equipment - Common rulesIEC 60364-5-52Low-voltage electrical installations - Selection and erection of electrical equipment - Wiring systemsIEC 60364-5-53Low-voltage electrical installations - Selection and erection of electrical equipment - Isolation, switching and controlIEC 60364-5-54Low-voltage electrical installations - Selection and erection of electrical equipment - Earthing arrangements and protective conductorsIEC 60364-5-55Low-voltage electrical installations - Selection and erection of electrical equipment - Other equipmentIEC 60364-5-56Low-voltage electrical installations - Selection and erection of electrical equipment - Safety servicesIEC 60364-6Low-voltage electrical installations - VerificationIEC 60364-7-701Low-voltage electrical installations - Requirements for special installations or locations - Locations containing a bath or showerIEC 60364-7-702Low-voltage electrical installations - Requirements for special installations or locations - Swimming pools and fountainsIEC 60364-7-703Low-voltage electrical installations - Requirements for special installations or locations - Rooms and cabins containing sauna heatersIEC 60364-7-704Low-voltage electrical installations - Requirements for special installations or locations - Construction and demolition site installationsIEC 60364-7-705Low-voltage electrical installations - Requirements for special installations or locations - Agricultural and horticultural premises

IEC 60364-7-706Low-voltage electrical installations - Requirements for special installations or locations - Conducting locations with restrictive movementIEC 60364-7-708Low-voltage electrical installations - Requirements for special installations or locations - Caravan parks, camping parks and similar locationsIEC 60364-7-709Low-voltage electrical installations - Requirements for special installations or locations - Marinas and similar locationsIEC 60364-7-710Low-voltage electrical installations - Requirements for special installations or locations - Medical locationsIEC 60364-7-711Low-voltage electrical installations - Requirements for special installations or locations - Exhibitions, shows and standsIEC 60364-7-712Low-voltage electrical installations - Requirements for special installations or locations - Solar photovoltaic (PV) power supply systemsIEC 60364-7-713Low-voltage electrical installations - Requirements for special installations or locations - FurnitureIEC 60364-7-714Low-voltage electrical installations - Requirements for special installations or locations - External lighting installationsIEC 60364-7-715Low-voltage electrical installations - Requirements for special installations or locations -Extra-low-voltage lighting installationsIEC 60364-7-717Low-voltage electrical installations - Requirements for special installations or locations -Mobile or transportable unitsIEC 60364-7-718Low-voltage electrical installations - Requirements for special installations or locations - Communal facilities and workplacesIEC 60364-7-721Low-voltage electrical installations - Requirements for special installations or locations - Electrical installations in caravans and motor caravansIEC 60364-7-722Low-voltage electrical installations - Requirements for special installations or locations - Supplies for electric vehiclesIEC 60364-7-729Low-voltage electrical installations - Requirements for special installations or locations - Operating or maintenance gangways

IEC 60364-7-740Low-voltage electrical installations - Requirements for special installations or locations - Temporary electrical installations for structures, amusement devices and booths at fairgrounds, amusement parks and circusesIEC 60364-7-753Low-voltage electrical installations - Requirements for special installations or locations - Heating cables and embedded heating systemsIEC60364-8-1Low-voltage electrical installations - Energy efficiencyIEC 60445Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductors terminations and conductorsIEC 60479-1Effects of current on human beings and livestock - General aspectsIEC 60479-2Effects of current on human beings and livestock - Special aspectsIEC 60479-3Effects of current on human beings and livestock - Effects of currents passing through the body of livestockIEC 60529Degrees of protection provided by enclosures (IP code)IEC 60644Specification for high-voltage fuse-links for motor circuit applicationsIEC 60664Insulation coordination for equipment within low-voltage systems - all partsIEC 60715Dimensions of low-voltage switchgear and controlgear. Standardized mounting on rails for mechanical support of electrical devices in switchgear and controlgear installations.IEC 60724Short-circuit temperature limits of electric cables with rated voltages of 1 kV (Um = 1.2 kV) and 3 kV (Um = 3.6 kV)IEC 60755General requirements for residual current operated protective devicesIEC 60787Application guide for the selection of high-voltage current-limiting fuses-link for transformer circuitIEC 60831-1Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operationIEC 60831-2Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1000 V - Part 2: Ageing test, self-healing test and destruction test

IEC 60947-1Low-voltage switchgear and controlgear - General rulesIEC 60947-2Low-voltage switchgear and controlgear - Circuit-breakersIEC 60947-3Low-voltage switchgear and controlgear - Switches, disconnectors, switch-disconnectors and fuse-combination unitsIEC 60947-4-1Low-voltage switchgear and controlgear - Contactors and motor-starters - Electromechanical contactors and motor-startersIEC 60947-6-1Low-voltage switchgear and controlgear - Multiple function equipment - Transfer switching equipmentIEC 61000 seriesElectromagnetic compatibility (EMC)IEC 61140Protection against electric shocks - common aspects for installation and equipmentIEC 61201Use of conventional touch voltage limits – Application guideIEC/TR 61439-0Low-voltage switchgear and controlgear assemblies - Guidance to specifying assembliesIEC 61439-1Low-voltage switchgear and controlgear assemblies - general rulesIEC 61439-2Low-voltage switchgear and controlgear assemblies - power switchgear and controlgear assembliesIEC 61439-3Low-voltage switchgear and controlgear assemblies - distribution boards intended to be operated by ordinary persons (DBO)IEC 61439-4Low-voltage switchgear and controlgear assemblies - Particular requirements for assemblies for construction sites (ACS)IEC 61439-5Low-voltage switchgear and controlgear assemblies - Assemblies for power distribution in public networksIEC 61439-6Low-voltage switchgear and controlgear assemblies - Busbar trunking systems (busways)IEC 61557-1Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - General requirementsIEC 61557-8Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V

d.c. - Equipment for testing, measuring or monitoring of protective measures - Insulation monitoring devices for IT systemsIEC 61557-9Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Equipment for insulation fault location in IT systemsIEC 61557-12Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Performance measuring and monitoring devices (PMD)IEC 61558-2-6Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V - Particular requirements and test for safety isolating transformers and power supply units incorporating isolating transformersIEC 61643-11Low-voltage surge protective devices - Surge protective devices connected to low-voltage power systems - Requirements and test methodsIEC 61643-12Low-voltage surge protective devices - Surge protective devices connected to low-voltage power distribution systems - Selection and application principlesIEC 61643-21Low voltage surge protective devices - Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methodsIEC 61643-22Low-voltage surge protective devices - Surge protective devices connected to telecommunications and signalling networks - Selection and application principlesIEC 61921Power capacitors - Low-voltage power factor correction banksIEC 61936-1Power installations exceeding 1 kV a.c. - Part 1: Common rulesIEC 62271-1High-voltage switchgear and controlgear - Common specificationsIEC 62271-100High-voltage switchgear and controlgear - Alternating-current circuit-breakersIEC 62271-101High-voltage switchgear and controlgear - Synthetic testingIEC 62271-102High-voltage switchgear and controlgear - Alternating current disconnectors and earthing switchesIEC 62271-103High-voltage switchgear and controlgear - Switches for rated voltages above 1 kV up to and including 52 kVIEC 62271-105High-voltage switchgear and controlgear - Alternating current switch-fuse

combinations for rated voltages above 1 kV up to and including 52 kVIEC 62271-200High-voltage switchgear and controlgear - Alternating current metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kVIEC 62271-202High-voltage switchgear and controlgear - High-voltage/low voltage prefabricated substationsIEC 62305-1Protection against lightning - Part 1: General principlesIEC 62305-2Protection against lightning - Part 2: Risk managementIEC 62305-3Protection against lightning - Part 3: Physical damage to structures and life hazardIEC 62305-4Protection against lightning - Part 4: Electrical and electronic systems within structuresIEC 62586-2Power quality measurement in power supply systems - Part 2: Functional tests and uncertainty requirementsIEC TS 62749Assessment of power quality - Characteristics of electricity supplied by public networks
Tags