INDEX
371
programming terminal, 296–299
timers and counters, 305
differential amplifier, 307
installing, 306–307
personal computers
versus,
296
Programmable logic controllers (PLCs), programs for,
310–316
assigning inputs and outputs, 312
converting schematics, 312–315
overview, 311–312
Program system, 109–110
Protective relaying, of transformers, 46–47
Puffer, 263
Push buttons, schematics for, 125–
127
Push-pull fiber-optic connectors, 322–
324
R
Raceways
for cooling equipment, 247
more than three conductors in, 93
trade sizes of,
17
–
18
underground, 12–15
Ramping, in variable-frequency drives, 192
Rate-load current, 245
Rates, industrial power, 37
Reactance (counter voltage), 218, 220, 222
Rectifiers
bridge, 300
in precipitators, 251
SCRs, 184–185, 190–192
single phase, full wave, 181–182
three phase, 183–184
Reduced voltage starters, 162–163
Reflectors, for lighting distribution, 288
Refraction, fiber optic, 319–320
Relays, 123.
See also
Overload relays; Timing relays
Repeat timers, 149
Resistance
calculating, 95–99
mil foot standard for, 94
values of, 222
Resistive AC circuit loading, 217
Revolutions per minute (RPM), 197
Rotation direction
of direct-current motors, 179–180
of single-phase motors, 175–176
of 3-phase motors, 166–169
RPM (revolutions per minute), 197
S
Safety
for grounding requirement tests, 9–11
lightning protection, 283–284
short-circuit protection, 207–210
transformer, 43
Scales, for site plans, 2–3
SCRs (silicon-controlled rectifiers)
for direct-current motors, 184–185
in power supply, 187
for variable frequency drives, 190–192
Seals, for hazardous locations, 332–335
Secondary resistance controllers, 166
Selective coordination, 255
Serial numbers, of motors, 201
Service entrances, to unit substations, 37–42
Service factor (SF), for motors, 200
SF (service factor), for motors, 200
Shielded cable, for PLCs, 306
Short-circuit protection, 207–210
Short shunt connections for DC motors, 176
Shunt trips, in circuit breakers, 259–261
Signal cable, for PLCs, 306
Signaling systems, 107–119
fire alarm system, 113–116
master clock, 108–109
paging system, 110–113
program system, 109–110
SI (International System of Units), 16–20
Silicon-controlled rectifiers (SCRs).
See
SCRs (silicon-
controlled rectifiers)
Single-mode fiber optic cable, 320
Single phase, full wave rectifiers, 181–182
Single-phase manual starter, 121–
122
heater for, 131–133
normally open contacts for, 133–135
operation of, 129–130
purpose of, 127–129
solder pot-type, 130
thermal, 130
Overload size, calculating, 206–207
P
Pad-mounted, oil-cooled transformers, 45–46
Paging system, 110–113
Panelboards, 62–70
branch-circuit protective devices, 66
feed-in adapter for, 74
harmonics and, 355–356
for hazardous locations, 335–
336
lighting and appliance, 63–66,
64
power, 67–69
protective device for, 67
in ventilating and exhaust systems,
244
Parallel conductors, 99–100
Parking lot lighting, 291
PCs (personal computers), PLCs
versus,
296
Pedestrian lighting, 291–
292
Percent impedance (%Z) of transformers, 29
Personal computers (PCs), PLCs
versus,
296
Phase rotation meter,
168
–
170
Phases, on motor nameplate, 198
Phase-shift control, 185–
186
Phase value, for voltage and current, 25
Plain-break oil-poor circuit breaker, 264
Plain entrance couplings, in lighting trolleys, 78
Plans and sitework, 1–23
construction, 1
grounding requirement tests, 4–11
clamp-on ground resistance test, 8
fall-of-potential test, 6–8
grounding and bonding for, 9, 11
overview, 4–5
safety for, 9–11
Wenner four-point method, 5–
7
interpreting, 11–16
metrics and NEC, 16–20
plan symbols, 1–4
Plant power factor, 233
PLCs (programmable logic controllers).
See
Programmable logic controllers (PLCs)
Plug-in busway, in feeder bus system, 56–60,
57,
58
Pneumatic timers, 146–
147
Positive ions, lightning and, 279
Potential difference, 279–
280
Pothead, in high-voltage section, 26–
28
Power, 287, 290–291
Power factor, 216–241
AC circuit loading, 217–223
apparent power, 220–223
importance of, 223
inductive, 217–219
resistive, 217
capacitors
for correcting, 229–235
installing, 235
testing, 235–239
correcting motor, 235
measurement of, 224–225
synchronous condensers, 225–228
tie-in, 228–229
Power panelboards, 67–69,
244
Power rates, industrial, 37
Power supply, for PLCs, 296
Precipitation units, 249–252
Pressure piling, 348
Preventative maintenance, of transformers, 44
Primary resistance starters, 161–162
Programmable logic controllers (PLCs), 295–309
components of, 296–306
CPU, 296–
297
input module, 300–302
internal relays, 304–305
I/O rack, 299–
300
off-delay circuit, 305–306
output module, 303–304
power supply, 296
overview, 153–156
primary resistance starters, 161–162
reduced voltage starters, 162–163
terminal identification of direct-current, 179
variable frequency drives, 185–193
construction of, 187
features of, 192–193
IGBTs (insulated gate bipolar transistor)
controls for, 188–189
inverter-rated, 190
issues in, 187–188
operating principles, 186
SCRs and GTOs for, 190–192
voltage and current, 186–187
wound-rotor induction, 163–166
Motors, installation of, 196–215
conductor size, 204–206
of direct-current motors, 202
locked-rotor current, 207
multiple motor calculations, 210–214
nameplate data, 197–201
overload size, 206–207
short-circuit protection, 207–210
of single-phase alternating-current motors, 202–203
tables of running current, 201–202
of three-phase motors, 204
of two-phase motors, 203–204
Motor starters, 124
Multimode fiber optic cable, 320
N
National Bureau of Standards WWV time signals, 109
National Center for Health Statistics, 282
National Electrical Manufacturers Association (NEMA),
28–29, 124, 197–198
National Electric Code (NEC).
See also
Code index
hazardous location classes, 329–330
overview, 9
in plans and sitework, 16–20
National Fire Protection Association (NFPA), 16
National Oceanic and Atmospheric Administration, U.S.
Department of Commerce, 283
NCHO (normally closed held open) switch contacts,
124–
125
NC (normally closed) switch contacts, 124–
125
NEC (National Electric Code).
See
National Electric
Code (NEC)
Negative ions, lightning and, 279
NEMA design code, for motors, 200–201
NEMA (National Electrical Manufacturers Association),
28–29, 124, 197–198
Neutral conductors,
5,
359
NFPA (National Fire Protection Association), 16
NOHC (Normally open held closed) switch contacts,
124–
125
NO (normally open) switch contacts, 124–
125
Normally closed held open (NCHO) switch contacts,
124–
125
Normally closed (NC) switch contacts, 124–
125
Normally open contacts for overload relays, 133–135
Normally open held closed (NOHC) switch contacts,
124–
125
Normally open (NO) switch contacts, 124–
125
N rating, for high voltage fuses, 28–29
Numerical system prefixes,
20
O
ODP (open drip proof) enclosure, for motors, 199
Off-delay circuit, for PLCs, 305–306
Off-delay timing relays, 140–142
Ohmmeters,
45,
100
Ohm’s law, 10
Oil circuit breakers, 263–264
Oil mist, removing, 249–250
Oil-poor circuit breaker, 264
Oil testing, of transformers, 48
On-delay timing relays, 140
One-shot timers, 149
Open drip proof (ODP) enclosure, for motors, 199
Output module, of PLCs, 303–304
Overcurrent protection, in unit substation, 29–
32
Overload relays, 127–135
bimetal strip-type, 130–131
Copyright 2015 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part. Due to electronic rights, some third party content may be suppressed from the eBoo
k and/or eChapter(s).
Editorial review has deemed that any suppressed content does not materially affect the overall learning experience. Cengage Learning reserves the right to remove additional content at any time if subs
equent rights restrictions require it.www.EngineeringBooksPdf.com