Radio Parameters – CIO
Cell Individual Offset (CIO)
Event A3 entering condiction
Ocn in the formula is CIO
Enumerated (-24,-22,-20, -18, -16, -14, -12, -10, -8, -6, -5, -4,
-3, -2, -1, 0, 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24),
unit: dB
To quicken handover from the serving cell to one neighbor
cell or to lower the handover threshold, you can increase the
CIO of the neighbor cell by 1 to 3 dB.
A3事件的进入条件为:
A3事件的离开条件为:
OffOcsOfsMsHysOcnOfnMn