DEFINISI API:DEFINISI API:
SUATU PROSES REAKSI KIMIA / SUATU PROSES REAKSI KIMIA /
OKSIDASI YANG SANGAT CEPAT OKSIDASI YANG SANGAT CEPAT
ANTARA UAP BAHAN BAKAR, ANTARA UAP BAHAN BAKAR,
OKSIGEN DAN PANAS PADA OKSIGEN DAN PANAS PADA
KOMPOSISI YANG CUKUP KOMPOSISI YANG CUKUP
DIIKUTI DENGAN TIMBULNYA DIIKUTI DENGAN TIMBULNYA
NYALA, CAHAYA, ASAP, GAS NYALA, CAHAYA, ASAP, GAS
( TOXID ) DAN ENERGI PANAS( TOXID ) DAN ENERGI PANAS
09/30/25 2
09/30/25 Created by ganjar budiarto 3
09/30/25 Created by ganjar budiarto 4
09/30/25 Created by ganjar budiarto 5
09/30/25 Created by ganjar budiarto 6
09/30/25 Created by ganjar budiarto 7
09/30/25 Created by ganjar budiarto 8
09/30/25 Created by ganjar budiarto 9
09/30/25 Created by ganjar budiarto 10
Phenomena
kebakaran
09/30/25 Created by ganjar budiarto 11
Phenomena
kebakaran
I
N
T
E
N
S
I
T
A
S
TIME
3 - 10 menit
D
E
C
A
Y
STEDY
Fully development fires
(600-1000
o
C)
Initiation
Source
Energi
G
r
o
w
th
09/30/25 Created by ganjar budiarto 12
Kerusakan
Korban Jiwa
Dampak
Lingkungan
Adanya
Penyimpangan
Standar K3
09/30/25 Created by ganjar budiarto 13
Effect of Fire on
People, Property
and
Environment
Fire Hazard volume
(Flammability & Quantity Materials)
Outcome
Rate of heat release
Flame spread
Smoke obscuration
Toxicity
Ignitibility by heat
transfer
09/30/2509/30/25 Created by ganjar budiartoCreated by ganjar budiarto 1414
Explosion
09/30/2509/30/25 Created by ganjar budiartoCreated by ganjar budiarto 1515
•PELEDAKAN FISIKA
(Physical Explosion Expanse)
Pelepasan tekanan uap/gas seperti :
Ketel uap, bejana tekanan, kompresor dll.
•PELEDAKAN KIMIA
(Chemical Explosion Explosive)
Pelepasan energi potensial dari reaksi
bahan kimia yang disertai pelepasan
energi panas yang tinggi dalam waktu
yang cepat
09/30/25 Created by ganjar budiarto 16
FIRE PREVENTION
POST FIRE
CONTROL
IN CASE FIRE CONTROL
PRE FIRE
CONTROL
FIRE SAFETY MANAGEMENT
(Pengendalian kebakaran)(Pengendalian kebakaran)
09/30/25 Created by ganjar budiarto 17
SASARAN
Diarahkan agar DAPAT TERATASI SEBELUM FLASHOVER
Kebakaran tidak meluas
Tidak terjadi korban
Tidak terjadi kerusakan
Terhindarkan kerugian yang besar
PRE FIRE CONTROL
Psl. 2 (1) (2) & (3)
09/30/25 Created by ganjar budiarto 18
Identifikasi potensi bahaya kebakaran
Identifikasi tingkat ancaman bahaya kebakaran
Identifikasi skenario kebakaran
Perencanaan system proteksi kebakaran (Aktif/Pasif)
Perencanaan tanggap darurat (FEP)
Pembentukan organisasi
Organisasi, Personel, Pelatihan/Sertifikasi
PRE FIRE CONTROL
Psl. 2 (1) (2) & (3)
Ref. Kepmennaker No 186/1999
09/30/25 Created by ganjar budiarto 19
IN CASE
FIRE CONTROL
Antara lain :
-Informasi sumber bahaya dan cara pencegahannya;
-Jenis sarana prot kebakaran, petunjuk pemeliharaan,
dan cara penggunaannya;
-Prosedur kerja aman
-Prosedur dalam keadaan darurat
Psl 2 (4)
FIRE EMERGENCY PLAN
09/30/25 Created by ganjar budiarto 20
IN CASE
FIRE CONTROL
Deteksi
Alarm
Padamkan-Lokalisir
Evakuasi
Rescue & P3K
Amankan
FIRE EMERGENCY PLAN
09/30/25 Created by ganjar budiarto 21
FIRE EMERGENCY PLAN
Lapis I
Pet. Peran
Kebakaran
Lapis II
Fire Men
Lapis III
Bantuan
dari lingkungan
Lapis IV
Dinas Pemadam
POSKO
09/30/25 Created by ganjar budiarto 22
09/30/25 Created by ganjar budiarto 23
POST
FIRE CONTROL
•INVESTIGASI
• ANALISIS
• REKOMENDASI
• REHABILITASI
09/30/25 Created by ganjar budiarto 24
DI TEMPAT KERJA ANDADI TEMPAT KERJA ANDA
►Apakah ada peluang utk terjadi Apakah ada peluang utk terjadi
kebakarankebakaran
►Apa konsekuensinya bila terjadi Apa konsekuensinya bila terjadi
kebakarankebakaran
►Upaya apa yang telah dilakukanUpaya apa yang telah dilakukan
09/30/25 Created by ganjar budiarto 25
•KEPMENAKER 75/2002 K3 LISTRIK
•PERMENAKER 02/89 Prot. Petir
•KEP. MENAKER KEP. 187/MEN/1999 (B3)
•PER. KHUSUS “EE” (BH. MUDAH TERBAKAR)
•PER. KHUSUS “K” (BH. MUDAH MELEDAK)
•PERMENAKER 04/80 APAR
•PERMENAKER 02/83 ALARM
•INST. MENAKER INS. 11/MEN/1997
PERATURAN DAN STANDAR TEKNIS
K3 PENANGGULANGAN KEBAKARAN
•PERMENAKER 04/87 P2K3
•PERMENAKER 05/96 SMK3
•KEP. MENAKER KEP. 186/MEN/1999
UNIT PENANGG. KEB. DI TEMPAT KERJA
Pengendalian
ENERGI
SARANA
PROTEKSI
KEBAKARAN
MANAJEMEN
K3
09/30/2509/30/25 Created by ganjar budiartoCreated by ganjar budiarto 2626
K
E
P
M
E
N
A
K
E
R
N
o
K
e
p
1
8
6
/
M
e
n
/
1
9
9
9
T
e
n
t
a
n
g
U
n
i
t
P
e
n
a
n
g
g
u
l
a
n
g
a
n
K
e
b
a
k
a
r
a
n
d
i
T
e
m
p
a
t
K
e
r
j
a
Kepmenaker No. 186/Men/1999,
Pasal 2 (1) dan (2) mewajibkan kepada
pengurus/ pengusaha untuk mencegah,
mengurangi dan memadamkan kebakaran,
melalui :
a)Pengendalian setiap bentuk energi
b)Penyediaan sarana deteksi, alarm, pemadam
kebakaran dan sarana evakuasi
c)Pengendalian penyebaran asap, panas dan
gas
d)Pembentukan unit penanggulangan
kebakaran di tempat kerja
e)Penyelenggaraan latihan dan gladi
penanggulangan kebakaran secara berkala
f)Memiliki buku rencana penanggulangan
keadaan darurat kebakaran bagi tempat kerja
yang mempekerjakan lebih dari 50 (lima
puluh )orang tenaga kerja dan atau tempat
kerja yang berpotensi bahaya kebakaran
sedang dan berat.
09/30/25 Created by ganjar budiarto 27
URAIAN TUGASURAIAN TUGAS
ORGANISASI TANGGAP DARURAT KEBAKARANORGANISASI TANGGAP DARURAT KEBAKARAN
•Melaporkan kondisi bahaya dan keadaan sarana prot.
kebakaran
•Melakukan tindakan pemadaman awal bila terjadi
kebakaran dan memandu evakuasi
•Bertanggung jawab di unit kerja tertentu.
(Lini I)
PET. PERAN KEBAKARAN (KLAS D)
Tugas pokok sesuai jabatan utamanya
Merupakan tugas tambahan selain tugas pokoknya
Pada waktu jam kerja
Ref. Kepmennaker No 186/1999
Psl 7
09/30/25 Created by ganjar budiarto 28
URAIAN TUGASURAIAN TUGAS
ORGANISASI TANGGAP DARURAT KEBAKARANORGANISASI TANGGAP DARURAT KEBAKARAN
Tugas :
1.Melakukan patroli rutin ke seluruh area kerja memantau
semua aspek pencegahan kebakaran.
2.Memelihara, memeriksa dan menguji semua sarana
proteksi kebakaran agar selalu dalam keadaan siap pakai.
3.Siap siaga melakukan tindakan menghadapi keadaan
darurat kebakaran untuk pemadaman dan
penyelamatan
(Lini II)
ANGG. REGU PEN. KEBAKARAN (KLAS C)
TUGAS POKOK:
Tanggung jawab di seluruh tempat kerja
(Diatur sistem shift)
Ref. Kepmennaker No 186/1999
Psl 8
09/30/25 Created by ganjar budiarto 29
KLAS B :
KOORDINATOR SUB UNIT PEN. KEBAKARAN
Tanggung jawab di unit kerja tertentu
Tugas :
Mengkoordinasikan program
penanggulangan kebakaran (inspeksi &
latihan)
•Memimpin operasi penanggulangan
kebakaran
URAIAN TUGASURAIAN TUGAS
ORGANISASI TANGGAP DARURATORGANISASI TANGGAP DARURAT
KEBAKARANKEBAKARAN
Ref. Kepmennaker No 186/1999
Psl 9
09/30/25 Created by ganjar budiarto 30
KLAS A :
PENANGGUNG JAWAB TEKNIK
PEN. KEBAKARAN
Tanggung jawab di seluruh tempat kerja
Tugas :
•Menyusun, melaksanakan dan evaluasi
program kerja pengendalian kebakaran
•Melakukan audit internal dan pengawasan
langsung
•Mempertanggung jawabkan pelaksanaan
syarat K3
URAIAN TUGASURAIAN TUGAS
ORGANISASI TANGGAP DARURAT ORGANISASI TANGGAP DARURAT
KEBAKARANKEBAKARAN
Ref. Kepmennaker No 186/1999
Psl 10
09/30/25 Created by ganjar budiarto 31
MEANS OF ESCAPEMEANS OF ESCAPE
KOMPARTEMENKOMPARTEMEN
SMOKE CONTROLSMOKE CONTROL
FIRE DAMPERFIRE DAMPER
FIRE RETARDANT/TREATMENT FIRE RETARDANT/TREATMENT
DETECTIONDETECTION
ALARMALARM
EXTINGUISHEREXTINGUISHER
SPRINKLERSPRINKLER
HYDRANT, ETCHYDRANT, ETC
A
K
T
I
F
A
K
T
I
F
P
A
S
S
I
F
P
A
S
S
I
F
09/30/25 Created by ganjar budiarto 32
PERATURAN MENTERI TENAGA KERJA RIPERATURAN MENTERI TENAGA KERJA RI
NO. PER-02/MEN/1983NO. PER-02/MEN/1983
TENTANG TENTANG
INSTALASI ALARM KEBAKARAN OTOMATIKINSTALASI ALARM KEBAKARAN OTOMATIK
Ruang lingkup
- Perencanaan
- Pemasangan,
- Pemeriksaan
- Pengujian
- Pemeliharaan
09/30/25 Created by ganjar budiarto 33
INSTALASI ALARM KEBAKARAN INSTALASI ALARM KEBAKARAN
OTOMATIKOTOMATIK
TUJUANTUJUAN
AGAR KEBAKARAN DAPAT TERDETEKSI SEDINI
MUNGKIN, SEHINGGA TINDAKAN YANG
DIPERLUKAN DAPAT SEGERA DILAKUKAN.
09/30/25 Created by ganjar budiarto 34
Detektor
Panel Indikator
Signal
alarm
FIREFOULT
NORMAL
Detektor
Signal
alarm
FIREFAULT
NORMAL
09/30/25 Created by ganjar budiarto 35
09/30/25 Created by ganjar budiarto 36
AUDIBLE ALARM
MCFA
VISIBLE ALARM
DETEKTOR
ANN
I
N
P
U
T
OUTPUT
Panas
Asap
Nyala
HYDRANT
09/30/25 Created by ganjar budiarto 38
JENIS DAN TIPE DETEKTOR
Panas
Asap
Nyala
•ULTRA VIOLET
•INFRA RED
•FIXED TEMPERATURE
•RATE OF RISE
•IONIZATION
•OPTIC
•Push bottom
•Full down
•break glass
Manual
09/30/25 Created by ganjar budiarto 39
ZONA DETECTION
Panas 40 titik
Asap 20 titik
Nyala 20 titik
•ZONE 1
•ZONE 2
•ZONE 3
EOL
EOL
EOL
Luas tiap zone deteksi
- ruang tanpa sekat mak. 2000 m
2
- terdapat sekat mak. 1000 m
2
09/30/25 Created by ganjar budiarto 40
INTERCONECTION
FIRE ALARM SYSTEMFIRE ALARM SYSTEM
MCFA
DETEKTOR
KEBAKARAN
LIFT
Off
POMPA
HYDRANT
supply daya
AC
Off
PRESS FAN
On
SPRINKLER
(FS)
09/30/25 Created by ganjar budiarto 41
CONTROL FIRE
INDIKATOR
DISCHART
CONTROL
PANEL
BUZER
ALARM
HEATSMOKE
VALVE
INSTALASI PEMADAM KEBAKARAN
AUTOMATIC TOTAL FLOODING SYSTEM
Media pemadam Halon
(F, Cl, Br)
!!!!!!!!!!!!
Mengandung potensi bahaya
keracunan
HARUS MEMILIKI IJIN K3
09/30/25 Created by ganjar budiarto 42
Double Warning Light
Control
Panel
Manual Abort
Station
Manual Release
Station
Discharge
Warning SignalCylinders
Heat
Detector
Smoke
Detector
Nozzle
Sirene
Pipe Work
F I RE E XT IN GUI S HAN T
Co n si stin g o f :
•1 ,1-Dich l oro, 2,2 , 2-trif lu o r o eth a n e(H CF C 1 2 3 )
•Pro p r ie t ary
CAUT ION :
•HE AVIE R TH AN AIR
•LE MON ODOUR
•KE EP C YL IN DE R C OOL , WEL L VE N TI LAT ED AND
SE C URE D AT A LL T I ME S
•ONL Y US E WI T H E QU IPME NT S UITA BLE FO R
CO NT AIN ED GA S
•US E I N AC CO RDAN C E WIT H MAT E RIAL SA FET Y
DAT A S HE E T AV AIL ABLE F ROM NE WS TAR
CH EMI C ALS (M ) SD N BH D
N o. 5, B l okB , Ja la n SS 13 /5 , Sub an g Ja ya I n du st ri al Est a te,
4 75 00 S el a ngor D a rul Eh san, M ala y sia
T el. : ( 60 3) 56 21 21 68 F ax. : (6 03 ) 5 6 21 11 68
C Y L . V OLU ME
G ROS S W E I G HT
NE T W EI G HT
FI L L D EN SI TY
K G
K G /L tr
L TR
K G
F IRE E X T IN GUI SH ANT
Co n s is t in g o f :
•1 ,1-Dich lo ro,2 , 2 ,2-tr iflu o ro e th a ne(H CF C 1 2 3 )
•Pro p r ie t a ry
CAUT ION :
•HEA VIER THA N AIR
•LEM ON O DOUR
•KEE P C YLIN DER C OOL, WE L L VE NT ILA TE D A ND
SE CU RED AT AL L T IME S
•ONL Y U SE WI TH E QUI PMEN T SU ITABL E FOR
CON T AIN ED GAS
•USE IN ACC OR DAN CE WIT H MAT ERIA L S AFE T Y
DATA S HE E T AVA ILA BLE F ROM NE WST AR
CHE MIC ALS (M) SDN BHD
N o. 5, Bl okB , J ala n SS 13 /5 , Sub an g Ja ya In dus t ri al E st at e,
475 00 Sel an go r Da rul Ehs an , Ma l aysi a
Te l . : (6 03 ) 56 2 12 16 8 Fa x. : ( 603 ) 56 2 11 16 8
C Y L. V OL UM E
G R OS S W EIG HT
NET W E I G HT
FI L L D E NS IT Y
KG
K G /Ltr
L TR
K G
09/30/25 Created by ganjar budiarto 43
09/30/25 Created by ganjar budiarto 44
09/30/25 Created by ganjar budiarto 45
09/30/25 Created by ganjar budiarto 46
FC-3-1-10 Perfluorobutane C
4F
10
HBFC-22B-1 Bromodifluoromethane CHF
2
Br
HCFC Blend ADichlorotrifluoroethane HCFC-123 (4. 75 %) CHCl
2CF
2
Chlorodifluoromethane HCFC-22 (82%) CHClF
2
Chlorotetrafluoroethane HCFC-124 ( 9. 5%) CHClFCF
3
Isopropenyl-1-methylcyclohexene 3. 75 %)
HCFC-124 Chlorotetrafluoroethane CHClFCF
3
HFC-125 Pentafluoroethane CHF
2CF
3
HFC-227 ea Heptafluoropropane CF
3
CHFCF
3
HFC-23Triflouromethane CHF
3
IG-541Nitrogen (52%) N
2
Argon (40%) Ar
Carbondioxide (8%) CO
2
MEDIA PEMADAM CLEAN AGENT
(Dikutip dari NFPA 2001)
09/30/25 Created by ganjar budiarto 47
CO2
CO2
DRY
POWDER
ALAT PEMADAM API RINGAN ALAT PEMADAM API RINGAN
Portable Fire ExtinguisherPortable Fire Extinguisher
09/30/25 Created by ganjar budiarto 48
ALAT PEMADAM API RINGAN
•DAPAT DIOPERASIKAN SATU
ORANG
•UNTUK PEMADAMAN MULA
KEBAKARAN
•SEBATAS VOLUME API KECIL
09/30/25 Created by ganjar budiarto 49
•Efektif
•Aman
•Tidak Merusak
Petugas
kompeten
Jenis dan
ukuran
tepat
Penempatan
tepat
Pemeliharaan
teratur
Perencanaan
Pengadaa
n
Sertifika
t
Fire risk
Assessmen
t
Kebijakan
09/30/25 Created by ganjar budiarto 50
•JENIS DAN UKURANNYA SESUAI
•MUDAH DILIHAT DAN MUDAH DIAMBIL
•KONDISI BAIK
•SETIAP ORANG DAPAT MENGOPERASIKAN
DENGAN BENAR, TIDAK MEMBAHAYAKAN
DIRINYA.
ALAT PEMADAM API RINGAN
Ref :
Pert. Menaker No Per-04/Men/1980
HARUS SIAP PAKAI PADA WAKTUNYA
K
la
s
ifi
k
a
s
i
Klas A
Klas B
Klas C
Klas D
Jenis kebakaran
Bahan padat kecuali logam
Bahan cair
Bahan gas
Listrik
Logam
Kalium, litium, magnesium
CIRI KHUSUS
1. Terdapat bara (kayu/arang/kertas)
2. Barang yang sulit/tidak ada gantinya
1. Tidak dapat bercampur air
3. Gas mengalir
4. Karena bereaksi dengan air
1. Aparat listrik bertegangan
2. Peralatan elektrik
Bertemperatur tinggi
KLASIFIKASI KEBAKARAN
2. Dapat bercampur air
09/30/25 Created by ganjar budiarto 52
API
Udara
Heat
Bahan bakar
Cooling
Smothering
Starving
Prinsip
PEMADAMAN
Dilution
09/30/25 Created by ganjar budiarto 53
JENIS MEDIA PEMADAM
JENIS BASAH
- AIR
- BUSA
JENIS KERING
- DRY POWDER
- CO2
- CLEANT AGENT
W
A
T
E
R
H
A
L
O
N
P
O
W
D
E
R
F
O
A
M
K
la
s
ifi
k
a
s
i
Klas A
Klas B
Klas C
Klas D
Jenis kebakaran
Bahan spt (kayu, kertas, kain dsb.
Bahan cair
Bahan gas
Panel listrik,
Kalium, litium, magnesium
Bahan berharga
Jenis media pemadam
Tipe basah Tipe kering
Air Busa Powder
Clean
Agent
VVV V VV V*)
XX XX VV**) VVV
XXX VVV VV V*)
X X VV V *)
XXX XXX VV VVV
XXX XXX Khusus XXX
Keterangan :
VVV:Sangat efektif X : Tidak tepat
VV:Dapat digunakan XX:Merusak
V :Kurang tepat / tidak dianjurkan XXX:Berbahaya
*):Tidak efisien **): Kotor / korosif
JENIS MEDIA PEMADAM KEBAKARAN DAN APLIKASINYA
09/30/25 Created by ganjar budiarto 55
KEGAGALAN APAR
Jenis tidak sesuai
Ukuran tidak sesuai
Macet/tidak berfungsi
Petugas
Salah penempatan
2
•belum ditunjuk
•tidak trampil
Tidak bertekanan
- bocor
Menggumpal
- tunda refill
W
A
T
E
R
H
A
L
O
N
P
O
W
D
E
R
F
O
A
M
09/30/25 Created by ganjar budiarto 56
Pengisian ulang dan Uji Ref. : Peraturan Menteri Tenaga Kerja
No. Per 04/Men/1980
Jenis Refilling
Halogen 3 th 5 th
Testing
Water 5 th 5 th
Mechanical Foam 3 th 5 th
Dry powder 5 th 5 th
Chemical Foam 1 th 5 th
CO
2
5-10 th 10-5-5 th
Refilling & Testing
09/30/25 Created by ganjar budiarto 57
Jenis media tidak sesuai
Klasifikasi api/kebakaran
KEGAGALAN APAR
W
A
T
E
R
H
A
L
O
N
P
O
W
D
E
R
F
O
A
M
Setiap jenis media pemadam masing-
masing memiliki keunggulan dan
kekurangan, bahkan dapat membahayakan
bagi petugas atau justru memperbesar api
09/30/25 Created by ganjar budiarto 58
Daya pemadamannya (fire ratting) lebih
rendah dari volume api/kebakaran (Fire
load)
Notasi Fire ratting didasarkan dari hasil Notasi Fire ratting didasarkan dari hasil
pengujian laboratories pengujian laboratories
STANDAR KLASIFIKASI DAYA PEMADAMANSTANDAR KLASIFIKASI DAYA PEMADAMAN
NotasiNotasi : Nilai & Klas : Nilai & Klas
AA
BBCC
DD
KEGAGALAN APAR
09/30/25 Created by ganjar budiarto 59
KLASIFIKASI KLASIFIKASI
A A
B B
C C
DD
Rating : Nilai angka : Nilai angka
1A 1A
2A 2A
3A 3A
4A 4A
6A 6A
10A 10A
20A 20A
40A40A
1B 1B
2B 2B
5B 5B
10B 10B
20B 20B
30B 30B
40B 40B
80B80B
09/30/25 Created by ganjar budiarto 60
C
O
2
N
2
09/30/25 Created by ganjar budiarto 61
09/30/25 Created by ganjar budiarto 62
APARAPAR
Sebagai sarana K3 (Safety Equipment) Sebagai sarana K3 (Safety Equipment)
Pengandung Potensi BahayaPengandung Potensi Bahaya
STANDAR APARSTANDAR APAR
APAR
Dirancang dengan tekanan > 14kg/cm
2
dapat mendorong seluruh medianya
(sisa mak 15%) dalam waktu min. 8 detik
Syarat :
- Angka keamanan min 4,13 x WP (65
o
C)
- Test pressure 1,5 x WP(65
o
C)
- Pengujian ulang tiap 5 tahun
09/30/25 Created by ganjar budiarto 63
Hydro Static TestHydro Static Test
09/30/25 Created by ganjar budiarto 64
09/30/25 Created by ganjar budiarto 65
Bursting Test Bursting Test
09/30/25 Created by ganjar budiarto 66
HYDROSTATIC TEST
P
r
e
s
s
u
r
e
Expansion
> 20 kg/cm2
1.5 WP
> 4.13 WP
09/30/25 Created by ganjar budiarto 67
TANDA PEMASANGAN
09/30/25 Created by ganjar budiarto 68
RESERVOAR
2
1
/
2
Inc
1
1
/
2
Inc
Out door
2
1
/
2 Inc
Bagian ke III
PEMELIHARAAN
SISTEM HYDRAN
DAN SPRINGLER
09/30/25 Created by ganjar budiarto 69
Komponen sistem Hidrant
-Sistem persediaan air (45 menit)
-Sistem Pompa
(Jockey, Utama & Cadangan)
-Jaringan pipa
-Kopling outlet / Pilar / Landing valve
-Slang dan nozle
-Sistem kontrol tekanan & aliran
RESERVOAR
Seamiest
Connection
2
1
/
2 Inc
1
1
/
2
Inc
Out door
2
1
/
2
Inc
FIRE HYDRANT
Jaringan instalasi pipa air
untuk pemadam kebakaran
yang dipasang secara permanen
09/30/25 Created by ganjar budiarto 70
KLASIFIKASI HUNIAN
Tingkat resiko bahaya kebakaran
Resiko Ringan
Resiko Sedang
Resiko Berat
Luas 1000-2000 M2
2 titik hydran, tambahan 1 titik
Tiap 1000M2
Luas 800-1600 M2
2 titik hydran, tambahan 1 titik
Tiap 800M2
Luas 600-1200 M2
2 titik hydran, tambahan 1 titik
Tiap 600M2
PERENCANAAN HYDRANT
09/30/25 Created by ganjar budiarto 71
09/30/25 Created by ganjar budiarto 72
Data input :
Klasifikasi hunian : Ringan
Sedang I, II, III,
Berat
Khusus
Variabel : Peruntukan bangunan
Jumlah dan sifat penghuni
Konstruksi bangunan
Flammability dan Quantity Material
(Fire loads)
Standard klasifikasi sistem : Ukuran kepala sprinkler
Kepadatan pancaran
09/30/25 Created by ganjar budiarto 73
H
i
g
h
z
o
n
e
M
e
d
i
u
m
Z
o
n
e
L
o
w
z
o
n
e
RESERVOAR
09/30/25 Created by ganjar budiarto 74
53
o
C
68
o
C
79
o
C
93
o
C
141
o
C
182
o
C
201
o
C
260
o
C
09/30/25 Created by ganjar budiarto 75
Yaitu :
Debit air yang dipancarkan oleh empat kepala sprinkler
dirancang mampu menyerap energi kalor (beban api)
yang ada dalam area yang dibatasi oleh empat kepala sprinkler
Q = a x V (l/men)
Dasar perencanaan sprinkler
Kepadatan pancaran dibagian hidrolik tertinggi dan terjauh
PERENCANAAN SPRINGKLER
Resiko Ringan
Resiko Sedang
Resiko Berat
2,25 mm/men
Luas mak. 84 m2
5 mm/men
I 72 m2
II144 m2
III360 m2
Kepadatan pancaran
7,5 - 12,5 mm/men
Luas mak. 260 m2
09/30/25 Created by ganjar budiarto 77
KARAKTERISTIK PENGAMAN
HUBUNG PENDEK, TERBUKA
BILA MERASAKAN 600% In
DALAM WAKTU 20 - 50 DETIK
KELENGKAPAN SIRKIT MOTOR
POMPA KEBAKARAN
BILA SUPLAI LISTRIK
TERPUTUS HARUS ADA
INDIKASI ALARM
TIDAK PERLU
PENGAMAN BEBAN LEBIH
KENDALI
•JENIS KABEL FRC
•DARI SISI IN COMING
•SEBELUM SAKELAR UTAMA
09/30/25 Created by ganjar budiarto 78
Syarat sarana Evakuasi Syarat sarana Evakuasi
►Aman sementara, terjamin kedap asap dan Aman sementara, terjamin kedap asap dan
panas;panas;
►Tidak dikunci;Tidak dikunci;
►Tidak terhalang oleh benda apapun;Tidak terhalang oleh benda apapun;
►Memiliki lampu darurat;Memiliki lampu darurat;
►Bukaan pintu kearah pelarian;Bukaan pintu kearah pelarian;
►Mudah dijangkau (pajang jarak tempuh Mudah dijangkau (pajang jarak tempuh
sependek mungkin)sependek mungkin)
►Ada petunjuk arah yang dapat dilihat dalam Ada petunjuk arah yang dapat dilihat dalam
keadaan gelap. keadaan gelap.