MDC Distillation Rate Improvement Fluconazole-III Production | API Pharma Plant

Background Product: Fluconazole-III Reactor: 4000L SSR Vapor Column: 6–7 m height, 5–6 inch dia Distillation: Plain, with shell & tube condenser

Identified Challenges Narrow and tall vapor column → high resistance Possibly insufficient heat input Condenser inefficiency Plain distillation limits driving force Possible air ingress

Recommendations (Part 1) Increase jacket temperature (within limits) Insulate vessel and lines to prevent heat loss Widen or shorten vapor line to reduce resistance Use chilled brine in condenser (≤10°C) Clean condenser tubes regularly

Recommendations (Part 2) Moderate agitation: 50–80 rpm Check for and prevent air leaks Apply slight vacuum if feasible Optional: install external reboiler Use pharma-grade defoamers if foaming occurs

Conclusion Optimize equipment design and heat input Explore vacuum distillation or reboiler use Ensure safety and validation before changes Review all changes with cross-functional teams

Prepared By

Prepared By: Production Team API Pharma Plant