mechanical ventilator settings and .pptx

olimalar 54 views 39 slides Jun 14, 2024
Slide 1
Slide 1 of 39
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39

About This Presentation

ventilator settings


Slide Content

mechanical ventilation settings

these alarms play a crucial role in patient safety, allowing healthcare providers to quickly address any issues that may compromise ventilation.

Trouble shooting high pressure alarm To correct problems associated with a high pressure alarm, consider the following steps: Perform endotracheal suctioning if indicated. Insert a bite block or pharyngeal airway to prevent the patient from biting the tube. Check for and rectify any kinks in the circuit or artificial airway. Administer a bronchodilator to relieve bronchospasm. Reposition the endotracheal tube if it is not correctly placed. Check for and remove any water in the circuit. Evaluate and address  patient-ventilator asynchrony . Inspect for a malfunction of the inspiratory or expiratory valves.

Troubleshooting To correct problems associated with a low pressure alarm, consider the following steps: Check for a leak or disconnection in the circuit. Inspect the exhalation valve for leaks. Ensure all connections are secure and tight. Examine the pilot balloon for leaks. Verify that the endotracheal tube is correctly positioned. Ensure the endotracheal tube cuff is adequately inflated. Adjust the  ventilator settings  as necessary

Troubleshooting To correct problems associated with a high frequency alarm, consider the following steps: Adjust the sensitivity setting to prevent false triggers. Perform endotracheal suctioning if secretions are likely causing increased respiratory effort. Increase the level of pressure support to ease the patient’s work of breathing. Increase the inspiratory flow setting to meet the patient’s demand. Adjust the FiO2 (fraction of inspired oxygen) setting to ensure adequate oxygenation. Administer pain or anxiety medication as indicated to manage underlying causes of increased respiratory rate.

Troubleshooting To address issues associated with an apnea alarm, consider the following steps : Check for leaks or disconnections in the circuit. Inspect for leaks or disconnections in the artificial airway. Increase the amount of ventilator support to assist the patient’s breathing efforts. Adjust the sensitivity setting to ensure the ventilator responds appropriately to the patient’s breathing attempts.

To address issues associated with a high PEEP alarm, consider the following steps: Prolong the patient’s expiratory time to reduce the buildup of auto-PEEP. Review ventilator settings to ensure they are appropriate for the patient’s current condition. Check for and correct any factors that may contribute to increased airway resistance or decreased lung compliance, similar to those that trigger a high-pressure alarm.

To address these issues, consider the following steps: Inspect and ensure the integrity of the circuit tubing and endotracheal tube cuff to identify and fix any leaks. Adjust the inspiratory flow setting to better match the patient’s inspiratory effort, ensuring the desired PEEP level is maintained throughout the breathing cycle.

Complications of Mech Vent Hemodynamic compromise Nosocomial infection Anxiety/ Stress/ Sleep deprivation Ulcers/ Gastritis/ Malnutrition Muscle deconditioning/ Vent dependence Increased intrathoracic pressure leading to systemic edema due to decreased venous return