mpat.UV.pptx...................................

akshuu707070 31 views 82 slides Mar 10, 2025
Slide 1
Slide 1 of 82
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53
Slide 54
54
Slide 55
55
Slide 56
56
Slide 57
57
Slide 58
58
Slide 59
59
Slide 60
60
Slide 61
61
Slide 62
62
Slide 63
63
Slide 64
64
Slide 65
65
Slide 66
66
Slide 67
67
Slide 68
68
Slide 69
69
Slide 70
70
Slide 71
71
Slide 72
72
Slide 73
73
Slide 74
74
Slide 75
75
Slide 76
76
Slide 77
77
Slide 78
78
Slide 79
79
Slide 80
80
Slide 81
81
Slide 82
82

About This Presentation

...


Slide Content

ULTRA VIOLET SPECTROSCOPY

Introduction Spectroscopy is the branch of science that deals with the measurement and interpretation of ELECTROMAGNETIC RADIATION (EMR) absorbed or emitted when the molecules or the atoms or ions of the sample move from one energy state to another.  At ground state, the energy of the molecule is the sum total of rotational, vibrational and electronic energies.

EMR is most made up of discrete particles called photons . EMR possess both wave and particle characteristics, i.e. it can travel in vacuum also.  The different types of EMR are Visible, Infra Red, Microwaves, Radio waves, X-rays, Gamma rays or Cosmic rays.  The energy of the radiation depends upon the frequency and the wavelength of the radiation. ENERGY OF EMR: E = h v   Where; E = Energy of radiation h = Plank’s constant (6.625 x 10-34 J/sec) v = Frequency of radiation

Absorption and the emission of energy in the electromagnetic spectrum take place in distinct separate pockets or photons Energy of a photon and the frequency matching its propagation are related as E = hν where, E = Energy (ergs), ν = Frequency (cycles sec– 1), h = Universal constant termed as Planck’s constant (6.6256 × 10– 27 erg sec) Wavelength and frequency are related as ν = c/λ ...where, λ = Wavelength ( cms ), c = velocity of propagation of radiant energy in vacuum (which is nothing but the speed of light in vacuum ; and is equivalent to 2.9979 × 1010 cm sec– 1). 4

The radiant power of a beam is directly proportional to the number of photons per second that are propagated in the beam. Monochromatic Beam : A beam that carries radiation of only one distinctly separate wave length is known as monochromatic. Polychromatic or Heterochromatic : A beam that carries radiation of several wavelengths is termed as polychromatic or heterochromatic. 5

Most organic molecules and functional groups are transparent in the portions of the electromagnetic spectrum - ultraviolet (UV) and visible (VIS) regions Wavelengths range from 190 nm to 800 nm The electromagnetic spectrum consists of a span of all electromagnetic radiation which further contains many subranges These can be further classified as radio waves, microwaves, infrared radiation, visible light, ultra-violet radiation, X-rays, gamma rays and cosmic rays in the increasing order of frequency and decreasing order of wavelength.

Principles of spectroscopy The principle is based on the measurement of spectrum of a sample containing atoms/ molecules. Spectrum is a graph of intensity of absorbed or emitted radiation by sample verses frequency ( ν ) or wavelength ( λ ). Spectrometer is an instrument design to measure the spectrum of a compound.

Principles of spectroscopy Absorption Spectroscopy: An analytical technique which concerns with the measurement of absorption of electromagnetic radiation. Example: UV (185 - 400 nm) / Visible (400 - 800 nm) Spectroscopy, IR Spectroscopy (0.76 - 15 μ m)

Principles of spectroscopy Emission Spectroscopy: An analytical technique in which emission (of a particle or radiation) is dispersed according to some property of the emission & the amount of dispersion is measured. Example: Mass Spectroscopy

Ultra violet Spectroscopy- Principle This is the earliest method of molecular spectroscopy. It is concerned with the study of absorption of UV radiation which ranges from 200 nm to 400 nm . Near UV Region: 200 nm to 400 nm Far UV Region: below 200 nm The colored compounds absorb radiations from 400 nm to 800 nm, but colorless compounds absorb in the UV region. The valence electrons absorb energy, thereby molecule undergoes electronic transition from ground state to excited state .

The absorption efficiency of an analyte is affected by: The nature of the analyte The number of available microstates The solvent The absorption efficiency of an analyte generally not affected by: Other (low conc.) solutes Temperature (within reason) Concentration This makes absorption spectroscopy one of the few bioanalytical methods where the signal intensity is directly proportional to the concentration .

When continuous radiation passes through a transparent material, a portion of the radiation may be absorbed. The residual radiation, when it is passed through a prism, yields a spectrum with gaps in it, called an absorption spectrum. Hence atoms or molecules pass from a state of low energy (the initial, or ground state) to a state of higher energy (the excited state). The Principle of UV-Visible Spectroscopy is  based on the absorption of ultraviolet light or visible light by chemical compounds, which results in the production of distinct spectra .

Light Absorbance: Light Transmission where I0: Light Intensity entering a sample I1: Light Intensity exiting a sample C: The concentration of analyte in sample L: The length of the light path in glass sample cuvette Ɛ: a constant for a particular solution and wave length

Ground State : Here, both π electrons are in the π orbital. This configuration is designated as π² , where the superscript represents the number of electrons in that orbital. Excited State : Here, an electron is in the π orbital while the other in the π* orbital (having an opposite spin). Thus, the resulting configuration ππ* is obviously less stable due to the fact that : ( i ) only one electron helps to hold the atom together, and (ii) the other electron tends to force them apart The electromagnetic radiation that is absorbed has energy exactly equal to the energy difference between the excited and ground states.

The possible electronic transitions in a molecule can be represented as: Energy required for excitation of different transitions are: n → π * < π → π * < n → σ * < σ → σ *

The energy required is highest for this transition than others. Saturated compounds usually show this type of transition. These peaks appear in vacuum UV or far UV region i.e. 125-135 nm. Example: Methane (CH 4 ) has C-H bond only and can undergo σ → σ * transition and shows absorbance maxima at 125 nm.

An electron from non-bonding orbital is promoted to anti-bonding π * orbital. Compounds containing double bond involving hetero atoms (C=O, C≡N, N=O) undergo such transitions. n → π * transitions require minimum energy and show absorption at longer wavelength around 300 nm.

π electron in a bonding orbital is excited to corresponding anti-bonding orbital π *. Compounds containing multiple bonds like alkenes, alkynes, carbonyl, nitriles , aromatic compounds, etc undergo π → π * transitions. Example: Alkenes generally absorb in the region 170 to 205 nm.

Saturated compounds containing atoms with lone pair of electrons like O, N, S and halogens are capable of n → σ * transition . These transitions usually requires less energy than σ → σ * transitions. The number of organic functional groups with n → σ * peaks in UV region is small (150 – 250 nm).

Beer-Lambert Law The greater the number of molecules capable of absorbing light of a given wavelength, the greater the extent of light absorption According to the Beer-Lambert Law the absorbance is proportional to the concentration of the substance in solution Hence UV-visible spectroscopy can also be used to measure the concentration of a sample. A = log(I ○/ I ) = ɛ cl for a given wavelength A = absorbance I ○ = intensity of light incident upon sample cell I = intensity of light leaving sample cell c = molar concentration of solute l = length of sample cell (cm) ɛ = molar absorptivity; s constant for a particular substance at a particular wavelength (dm3 mol-1 cm-1) 23

Spectrum If the absorbance of a series of sample solutions of known concentrations are measured and plotted against their corresponding concentrations, the plot of absorbance versus concentration should be linear if the Beer-Lambert Law is obeyed. This graph is known as a calibration graph. A calibration graph can be used to determine the concentration of unknown sample solution by measuring its absorbance, as illustrated beside. 24

25

LAW OF LIGHT ABSORPTION-BEER LAMBERT`S LAW There are the two empirical laws, which govern the absorption of light by molecules. Beer’s law relates the absorption to the concentration of absorbing solute and Lambert’s law relates the total absorption of optical path length. They are most conveniently used as the Beer-Lambert’s Law.  According to the Beer-Lambert’s Law: “The intensity of the absorption is directly proportional to the concentration of the sample and the path length of the sample.” 

Mathematical equation for Beer-Lambert’s Law : A = ℮CT Where; A = Absorbance or Optical Density ℮ = Molecular Extinction Coefficient C = Concentration of the drug (m mol /lit) T = Path length (usually 10mm or 1cm)

DEVIATIONS FROM BEER`S LAW  DILUTE SOLUTIONS (TRUE DEVIATIONS): Applicable for dilute solutions only. The index of refraction for the absorbed radiation is changed at high concentration and hence, Beer’s law is not obeyed.  INSTRUMENTAL DEVIATIONS: Instrumental deviations are due to: Stray radiation reaching the detector Sensitivity changes in the detector employed Fluctuation of radiation source Defect in detector amplification system

CHEMICAL DEVIATIONS: The absorbing species in the solution may undergo ionization, dissociation or even may react with the solvent. These processes may produce two or more species in the solution with varying absorptivity values. It can be corrected by the use of buffers, choosing suitable solvent and by selecting appropriate narrow band of wavelength for measurements.

Limitations of Beer-Lambert law Beer law and Lambert law is capable of describing absorption behavior of solutions containing relatively low amounts of solutes dissolved in it (<10mM). When the concentration of the analyte in the solution is high (>10mM), the analyte begins to behave differently due to interactions with the solvent and other solute molecules and at times even due to hydrogen bonding interactions At high concentrations, solute molecules can cause different charge distribution on their neighboring species in the solution. Since UV-visible absorption is an electronic phenomenon, high concentrations would possibly result in a shift in the absorption wavelength of the analyte. 30

Due to the analyte molecules association, dissociation and interaction with the solvent a product with different absorption characteristics are observed For example, phenol red undergoes a resonance transformation when moving from the acidic form (yellow) to the basic form (red). Due to this resonance, the electron distribution of the bonds of molecule changes with the pH of the solvent in which it is dissolved. Since UV-visible spectroscopy is an electron-related phenomenon, the absorption spectrum of the sample changes with the change in pH of the solvent. It is observed that the deviations in absorbance over wavelengths is minimal when the wavelength observed is at the  λ max . Due to this reason absorption measurements are taken at wavelengths. Lambda max ( λ max ):  The wavelength at which a substance has its strongest photon absorption  (highest point along the spectrum's y-axis). This ultraviolet-visible spectrum for lycopene has λ max  = 471 nm. 31

32

33 Acid and Base forms of phenol red along with their UV spectra at different pH demonstrates chemical deviations of Beer-Lambert law in UV-Visible spectroscopy

Due to Mismatched Cells or Cuvettes If the cells holding the analyte and the blank solutions are having different path-lengths, or unequal optical characteristics, it is obvious that there would be a deviation observed in Beer-Lambert law. In such cases when a plot of absorbance versus concentration is made, the curve will have an intercept k and the equation will be defined as: A = εbc + k In today’s instrument this problem is generally not observed, however if it is present, appropriate linear regression to quantify this deviation must be made. 34

Spectrum Absorption spectra may be presented in a number of fashions A) Wavelength Vs Absorbance B) Wavelength Vs Molar Absorptivity C) Wavelength Vs Transmittance 35

SOLVENTS The choice of the solvent to be used in ultraviolet spectroscopy is quite important. The first criterion for a good solvent is that it should not absorb ultraviolet radiation in the same region as the substance whose spectrum is being determined. Usually, solvents that do not contain conjugated systems are most suitable for this purpose. Some common ultraviolet spectroscopy solvents and their cutoff points or minimum regions of transparency are listed here. Water, 95% ethanol, and hexane are most commonly used 36

A second criterion for a good solvent is its effect on the fine structure of an absorption band Below figure illustrates the effects of polar and nonpolar solvents on an absorption band. A nonpolar solvent does not hydrogen bond with the solute, and the spectrum of the solute closely approximates the spectrum that would be produced in the gaseous state, in which fine structure is often observed. In a polar solvent, the hydrogen bonding forms a solute–solvent complex, and the fine structure may disappear.

A third criterion for a good solvent is its ability to influence the wavelength of ultraviolet light that will be absorbed via stabilization of either the ground or the excited state. Polar solvents do not form hydrogen bonds as readily with the excited states of polar molecules as with their ground states, and these polar solvents increase the energies of electronic transitions in the molecules. Polar solvents shift transitions to shorter wavelengths. On the other hand, in some cases the excited states may form stronger hydrogen bonds than the corresponding ground states. In such a case, a polar solvent shifts an absorption to longer wavelength since the energy of the electronic transition is decreased.

Chromophore The part of a molecule responsible for imparting color, are called as chromophores . OR The functional groups containing multiple bonds capable of absorbing radiations above 200 nm due to n → π * & π → π * transitions. e.g. NO 2 , N=O, C=O, C=N, C≡N, C=C, C=S, etc

Chromophore To interpret UV – visible spectrum following points should be noted: Non-conjugated alkenes show an intense absorption below 200 nm & are therefore inaccessible to UV spectrophotometer. Non-conjugated carbonyl group compound give a weak absorption band in the 200 - 300 nm region. Example: Acetone has λ max = 279 nm Cyclohexane has λ max = 291 nm.

Chromophore When double bonds are conjugated in a compound λ max is shifted to longer wavelength. Example: 1,5 - hexadiene has λ max = 178 nm 2,4 - hexadiene has λ max = 227 nm Conjugation of C=C and carbonyl group shifts the λ max of both groups to longer wavelength. Example: Ethylene has λ max = 171 nm Acetone has λ max = 279 nm

Auxochrome The functional groups attached to a chromophore which modifies the ability of the chromophore to absorb light , altering the wavelength or intensity of absorption. OR The functional group with non-bonding electrons that does not absorb radiation in near UV region but when attached to a chromophore alters the wavelength & intensity of absorption. Examples: Benzene λ max = 255 nm Phenol λ max = 270 nm Aniline λ max = 280 nm

Absorption and intensity shifts

Instrumentation Source of light Monochromators Sample cells Solvents Detectors Recorders

The typical ultraviolet–visible spectrophotometer consists of a light source a monochromator and a detector. Light source: It is usually a deuterium lamp, which emits electromagnetic radiation in the ultraviolet region of the spectrum. A second light source, a tungsten lamp, is used for wavelengths in the visible region of the spectrum. Monochromator: It is a diffraction grating; its role is to spread the beam of light into its component wavelengths. A system of slits focuses the desired wavelength on the sample cell. The light that passes through the sample cell reaches the detector, which records the intensity of the transmitted (I).

Source of light H 2 discharge lamp Deuterium discharge lamp Xenon discharge lamp Mercury arc lamp

Monochromators Grating monochromators

Sample cell Made up of Quartz

Detector It is generally a photomultiplier tube, although in modern instruments photodiodes are also used. In a typical double-beam instrument, the light emanating from the light source is split into two beams, the sample beam and the reference beam. When there is no sample cell in the reference beam, the detected light is taken to be equal to the intensity of light entering the sample (Io) The sample cell must be constructed of a material that is transparent to the electromagnetic radiation being used in the experiment. For spectra in the visible range of the spectrum, cells composed of glass or plastic are generally suitable. For measurements in the ultraviolet region of the spectrum, however, glass and plastic cannot be used because they absorb ultraviolet radiation. Instead, cells made of quartz must be used since quartz does not absorb radiation in this region.

A modern improvement on the traditional spectrophotometer is the diode-array spectrophotometer. A diode array consists of a series of photodiode detectors positioned side by side on a silicon crystal. Each diode is designed to record a narrow band of the spectrum. The diodes are connected so that the entire spectrum is recorded at once. This type of detector has no moving parts and can record spectra very quickly. Furthermore, its output can be passed to a computer, which can process the information and provide a variety of useful output formats. Since the number of photodiodes is limited, the speed and convenience described here are obtained at some small cost in resolution. For many applications, however, the advantages of this type of instrument outweigh the loss of resolution.

Detectors

Detectors Photomultipier detector

Recorders Display devices: The data from a detector are displayed by a readout device, such as an analog meter, a light beam reflected on a scale, or a digital display , or LCD . The output can also be transmitted to a computer or printer.

Types of spectrophotometer a) Single-beam b) Double-beam

THE WOODWARD–FIESER RULES Conjugated dienes/trienes In general, conjugated dienes exhibit an intense band i n the region from 217 to 245 nm, owing to a pi-pi * transition Repulsion between terminal lobes of Ψ2 increases energy of HOMO (Ψ2) in s-cis form. Hence, less energy ( ie . Higher wavelength) is required for Ψ2 è Ψ3 * transition. 56

Alkyl substitution produces bathochromic shifts and hyperchromic effects However, with certain patterns of alkyl substitution, the wavelength increases but the intensity decreases. The 1,3-dialkylbutadienes possess too much crowding between alkyl groups to permit them to exist in the s-trans conformation They convert, by rotation around the single bond which absorbs at longer wavelengths but with lower intensity By studying a vast number of dienes of each type, Woodward and Fieser devised an empirical correlation of structural variations that enables us to predict the wavelength at which a conjugated diene will absorb 57

58

Calculation of λ max Each type of diene or triene system is having a certain fixed value at which absorption takes place; this constitutes the  Base value or Parent value . The contribution made by various alkyl substituents or ring residue, double bond extending conjugation and polar groups such as –Cl, -Br etc are added to the basic value to obtain λ max  for a particular compound   Homoannular Diene:-  Cyclic diene having conjugated double bonds in same rings Heteroannular Diene:-  Cyclic diene having conjugated double bonds in different rings 59

Exocyclic Double Bonds These types of bonds are covalent chemical bonds which contain two carbon atoms bonded to each other via a sigma ( σ ) bond and a pi bond . This type of double bonds has one of the two carbon atoms in the ring structure. The name exocyclic refers to the presence of the double bond external to the cyclic structure. But this double bond is still connected to the cyclic structure via one of the two double-bonded carbon atoms. 60

Endocyclic Double Bonds These types of double bonds are covalent chemical bonds that contain two carbon atoms bonded to each other via a sigma ( σ ) bond and a pi bond These covalent chemical bonds have both carbon atoms of the double bond in the ring structure . In other words, both carbon atoms of the endocyclic double bond are members of the cyclic structure 61

Identification of Exocyclic bond Any double bond which is outside the ring A but is directly attached to the ring 62

Increment values Ring residues: Attachment of the rings: When chemical bonds are opened ring will be opened Shouldn't break the ring in between chromophore Extended conjugation: Extra double bond 63

Calculation 64

65

Conjugated Triene system Both homoannular and heteroannular are there Since base value is more for homoannular than heteroannular ring system we have to consider homoannular base value Acyclic/Open chain system No extended conjugation No exocyclic bonds since not a cyclic system 66

67

68

THE WOODWARD–FIESER RULES Enones he conjugation of a double bond with a carbonyl group leads to intense absorption due to a pi-pi * transition of the carbonyl group The absorption is found between 220 and 250 nm in simple enones The n-p * transition is much less intense and appears at 310 to 330 nm 69

αβ unsaturated double bond-210nm Phenyl ring extended conjugation-90nm 70

71

72

Alkene with more ring residues is considered for λ max 73

a,b -Unsaturated aldehydes generally follow the same rules as enones except that their absorptions are displaced by about 5 to 8 nm toward shorter wavelength than those of the corresponding ketones Benzoyl derivatives: 74

75

Applications Concentration measurement Prepare samples Make series of standard solutions of known concentrations Set spectrophotometer to the λ of maximum light absorption Measure the absorption of the unknown, and from the standard plot, read the related concentration

Detection of Impurities UV absorption spectroscopy is one of the best methods for determination of impurities in organic molecules. Additional peaks can be observed due to impurities in the sample and it can be compared with that of standard raw material. Applications

3. Structure elucidation of organic compounds. From the location of peaks and combination of peaks, UV spectroscopy  elucidate structure of organic molecules: the presence or absence of unsaturation ,  the presence of hetero atoms. 4. Chemical kinetics Kinetics of reaction can also be studied using UV spectroscopy. The UV radiation is passed through the reaction cell and the absorbance changes can be observed. Applications

Applications 5. Detection of Functional Groups Absence of a band at particular wavelength regarded as an evidence for absence of particular group.

Applications 6. Molecular weight determination Molecular weights of compounds can be measured spectrophotometrically by preparing the suitable derivatives of these compounds. For example, if we want to determine the molecular weight of amine then it is converted in to amine picrate . Determination of dissociation constant of acids and bases ( pKa ) Concentration Vs absorbance graph is plotted at different pH. The slope of the curve gives the value of the dissociation constant ( pKa ). The value log ( ionised / unionised ) can be determined using the equation

Applications Quantitative analysis of pharmaceutical substances Drug Solvent λ (nm) E (1%,1cm) Acetazolamide 0.1 N HCl 265 474 Cyanocobalamin Water 361 207 Griseofulvin Alcohol 291 686 Riboflavin Acetate buffer 444 323 Verapamil tablets Water 378 118