Sims bivalved
speculum
•2 blades & handle
•Adv
•retracts posterior vaginal wall
•The groove in the centeralso drains the
secretion or bleeding thus keeping the area
dry
•Disadv
•Not self retaining (need an assistant to hold
speculum )
•Enter laterally
•PGE1 introduction
•Uterine prolapse
•FC,D&C,cervicalpunch bipsy
•Pap smear
•Push bladder in VH
tony 2010 mbbs 3
Uses
•Use in GynaeOPD for following procedures: Taking Pap Smear , Insertion
and removal of Copper T , Colposcopy ,Taking swabs,
Hyseterosalpingography(HSG)
Use in GynaeOperations:D&C , Cervix Biopsy , Vaginal Hysterectomy ,
FothergillsOperation, Repair of Vesicovaginal fistula, Hysteroscopy.
Use in Obstetrics: For inspection ( Bluish discoloration in early pregnancy,
local cause for threatened abortion, local cause in APH), First trimester
MTP by suction curettage . In second trimester MTP by EthacredylLactate.
Osthighteningor cervical encircalage,
Removal of osthighteningstitch at the onset of laboror at 38 wks.
Inspection for suspected rupture of membranes.
After forceps delivery to trace for cervical tears.
tony 2010 mbbs 4
Cuscosbivlavedself
retaining speculum
•Retract anterior & posterior walls
of cervix
•Disdv
•Obscures vaginal walls so lesion may
be missed
•Insert /remove IUD
tony 2010 mbbs 5
Retractor
tony 2010 mbbs 6
Doyens’ retractor
•Nontraumaticblunt
•Depress bladder in CS
tony 2010 mbbs 7
Doyens retractor
•This instrument is used for retracting bladder during abdominal
operations like LSCS , abdominal hysterectomy , laparotomy.
•The smooth edge and the curvature retracts the bladder and protects
it during surgery
tony 2010 mbbs 8
Kellys retractor
tony 2010 mbbs 9
Abdominal wall
retractor self retaining
tony 2010 mbbs 10
Forceps
tony 2010 mbbs 11
Artery forceps
tony 2010 mbbs 12
Artery forceps
•This is a hemostat. Used for
clamping bleeding vessels. It is
also used for grasping tissue at the
time of operation. ( Opening and
closing peritoneum) . It is also
used to hold stay sutures. It comes
in two shapes straight and curved.
•Usually straight is used for rough
work like stay and curved is used
as hemostat.
tony 2010 mbbs 13
tony 2010 mbbs 14
Mosquito
Small artery forceps
tony 2010 mbbs 15
Needle Holder
•This instrument is used for
grasping needle at the time of
suturing. The inner surface of tip
has crisscross serrationsand a
small grove for firm grasp of the
curved needle.
•The box joint is placed very close
to tipto give adequate pressure
because of the lever effect.
tony 2010 mbbs 16
Volsellum forceps
•To hold
•anterior lip of Cx
•posterior lip of Cx
•Cervical stump in subtotal hysterectomy
Its a long instrument with gentle curve so that
the line of vision is not obstructed. The tip of the
blades have 3-4 teeth
tony 2010 mbbs 17
•Insertion of IUCD , CxBiopsy D&C, First trimester MTP with Suction
Evacuation. CxBiopsy , Fothergillsoperation, Vaginal Hysterectomy
Posterior lip of the cervix is grasped for post. colpotomy.
•Since the teeth are sharp it is not used in pregnancy as it may cause
cervical tares and lacerations. Instead sponge holding forceps is used
to grasp the cervix
tony 2010 mbbs 18
Allis tissue forceps
•Interlocking teeth catch and lock
•To hold
•peritoneum rectus sheath
•Anterior lip of Cx
•Traumatic arrest hge
Sterilization: By Autoclaving
This instrument is used for grasping tough structures like
Rectus sheath or fascia in operations like tubectomy,LSCS
,abdominal hysterectomy.
tony 2010 mbbs 19
Tenaculum forceps
•Long with single tooth at tip
•Catch present
•Major gynaecprocedures like
abdominal hysterectomy
•Catch hold of vault/cervix
•Traumatic hold fimstructures like
cervix
tony 2010 mbbs 20
Babcock's Forceps
The tip is atraumatic as there are no sharp
tooth
This instrument is used for grasping tubular
structures like fallopian tube in tubectomyin
modified Pomeroy's operation ,
ureter ,appendix etc.
tony 2010 mbbs 21
Sponge holding
forceps
•Hold the pregnant uterus (less
traumatic than volsellumforceps )
•In traumatic PPH
•(walking around cervix)
•atleast3 sponge ( one at 12 0 clock
position & other to look for trauma)
holding forceps to visualize Cx
•Cleaning & draping in surgical
procedures
tony 2010 mbbs 22
Green Armytage
Forceps
This forceps is used as a hemostatin
caesarean operation. As the tips are broad
wide area can be
compressed.
In LSCS the cut uterine edges bleed . This
forceps is applied to the two angles and
lower and upper edge of
the incision.
The common indications for LSCS are fetal
distress in first stage, CPD , abnormal
presentations like
transverse lie , brow , breech in primi
,previous two scars on the uterus.
tony 2010 mbbs 23
Kocher's Forceps (
Clamp)
The tips of the blades have teeth so that the
tissue does not slip
This instrument is used for holding pedicles
in hysterectomy.
The blades can either be straight or curved.
This instrument is used in hysterectomy to
clamp pedicles which are then transfixed
It is also used for salpingectomy in ectopic or
oophorectomy in ovarian mass. This can also
be used for clamping umbilical cordnew
born at the time of delivery or for artificial
low rupture of membranes ( ARM).
tony 2010 mbbs 24
Ovum Holding Forceps
removing the products of conception in inevitable , incomplete
abortion and in MTP operations.
No catch
The tip of this instrument is rounded cup like to avoid
perforation and to hold large tissue. This instrument has no
catch . This is to
avoid perforation of wall.
tony 2010 mbbs 25
Dissecting forceps non toothed
tony 2010 mbbs 26
myoma screw
•To hold the fundus of uterus in
myomectomy & hysterectomy
tony 2010 mbbs 27
Towel clip
•Hold towels
tony 2010 mbbs 28
Leech Wilkinson cannula
•Hydrotubationfor tubal patency
•It is straight instrument with conical tip. This cone is screwed into the
cervix. Then dye is injected
tony 2010 mbbs 29
Scissors
tony 2010 mbbs 30
Mayo scissors
Straight mayo scissors
Curved mayo scissors
tony 2010 mbbs 31
Episiotomy Scissors.
tony 2010 mbbs 32
catheter
tony 2010 mbbs 33
Malecots catheter
tony 2010 mbbs 34
Foleys catheter
•Continousbladder drainageafter
surgery
•Abdominal , Vaginal Hysterectomy ,
Wertheim's Hysterectomy, Repair of
Vesicovaginal fistula.
•Atonic bladder
•EASI
•second trimester MTP for extra
amniotic instillation of ethacredyl
lactate .
•sono salpingography
tony 2010 mbbs 35
Metal catheter
•Intermittent drainage as in vaginal hysterectomy
tony 2010 mbbs 36
D&C
tony 2010 mbbs 37
Uterine sound
Its a long instrument with blunt tip ( To avoid
perforation) About 5 cmsfrom the tip its
bend to make angle of 30 degrees.
It has marking on it for measurements. (
Bladder sound has no markings )
The angle helps to negotiate curvature of the
uterus (Anteflexion). It is used for measuring
uterocervicallength , length of thcervix(for
diagnosing supra vaginal elongation of the
cervix). To feel for any pathology inside the
cavity like fibroid ( Sub mpolyp) Congenital
anomalies like septa or bicornuateut.
Adhesions or synachae. To feel for the
misplaced IUCD.
It can create false passage or perforation
especially in soft uterus in pregnancy.
tony 2010 mbbs 38
Uterine Curette
Blunt endobstetric
Sharp gynaec
Use for scraping endometrial cavity to obtain
sample for histopathology.
Diagnostic D&C is done commonly for
Menorrhagia, Endometrial Carcinoma,
Infertility ,Tuberculosis of endometrium .
It also has secondary beneficial advantage of
reducing the bleeding in menorrhagia.
tony 2010 mbbs 39
Hegar'sDilator
Dilate cervix
long rod like instrument with gentle curve
and tapering tip.
It is used for dilatation of the cervix in
procedures like
D&C , D& E , Fothergillsoperation ,
Hysteroscopy , Cervical Stenosis , Primary
dysmenorrhoea.
The dilators are numberdas per outer
diameter ( No 8 means outer diameter of 8
mm) For D&C dilation up to 8 is
Done For MTP dilatation up to 12 may be
required. Very large dilatation can cause
cervical incompetenceperforation
tony 2010 mbbs 40
Mathew duncans
dilator
tony 2010 mbbs 41
Papsmear
tony 2010 mbbs 42
Cevixsampling devices
tony 2010 mbbs 43
Ayre's Spatula
•Made of wood so that cells can adhere to its porous surface.
•Use for taking Pap Smearfor screening of carcinoma cervix.
•The long end is inserted into cervical canal and rotated in 360 degrees.
•The exfoliated cells obtained are smeared on glass slide and fixed in Koplicks
jar which contains ether and alcohol in equal amount. or by hair spray.
•The other broad end is used for obtaining cells from lateral vagina for
knowing the hormonal status & buccal smear
tony 2010 mbbs 44
Cervical brush
Pap smear
tony 2010 mbbs 45
Family planning
tony 2010 mbbs 46
Copper t
•380 A (380SAof copper)}commonly used
tony 2010 mbbs 47
tony 2010 mbbs 48
tony 2010 mbbs 49
tony 2010 mbbs 50
tony 2010 mbbs 51
tony 2010 mbbs 52
tony 2010 mbbs 53
Female condom
tony 2010 mbbs 54
Male condom
tony 2010 mbbs 55
Balloon tamponadewith condoms for PPH
tony 2010 mbbs 56
Karman cannula-
plastic
It is of different sizes and the approximate
size required for a
particular case equals to the weeks of
pregnancy to be terminated
The plastic cannula has got advantages
over a metallic one-
as it causes less damage to the uterine wall
and the products
sucked out can be visible. The vacuum
must be broken before
withdrawal
tony 2010 mbbs 57
Karman cannula -Metallic
Suction evacuation
MTP
To remove products of conception
Missed abortion
tony 2010 mbbs 58
tony 2010 mbbs 59
Karman's Syringe ( Menstrual Regulation)
Menstrual Regulation and endometrial aspiration.
The capacity is 50 ml. The tip has a rubber
attachment with valve.
tony 2010 mbbs 60
tony 2010 mbbs 61
Laparoscopy
tony 2010 mbbs 62
Trocar and cannula
Used for Laparoscopy
Trocar is put in to the cannula and then inserted into
abdominal cavity for laparoscopy. It is also called port ( port of
entry to telescope and other instruments.) It is numbered as
per outer diameter. 10 mm is used for operative telescope, 7
mm is used for Band Applicator for Tubal Ligation, 5mm is used
for other hand instruments like grasper etc. A Reducer sleeve is
available to use large size port for small instrument. It has a
trumpet valve to prevent gas leak. On one side there is opening
for connecting it to gas ( CO2 or Air)
tony 2010 mbbs 63
Varies Needle
•putting Air or CO2 in the peritoneal cavity) for laparoscopy..
tony 2010 mbbs 64
tony 2010 mbbs 65
tony 2010 mbbs 66
Operative vaginal delivery
tony 2010 mbbs 67
VaccumExtractor(Ventouse).
tony 2010 mbbs 68
Cup for vacuum extraction
tony 2010 mbbs 69
tony 2010 mbbs 70
tony 2010 mbbs 71
tony 2010 mbbs 72
Wrigley's outlet Forceps
tony 2010 mbbs 73
•Obstetric forceps for out let forceps delivery. It has pelvic curve. Parts of
the forceps are blades ( which has windows or fenestrate
•for firm grip of the head) ,Shank , Lock( English lock for Wriglysforceps) ,
Handle.
•Simson's Short forceps is straight forceps with only cephalic curve and no
pelvic curve.
•Some of the Pre requisite for forceps application : Dilatation of the cervix
must be full (10cm) Station of Vertex at plus 2 or plus 3 (for outlet
forceps),membranes should be ruptured , pelvis must be adequate. Uterine
contractions must be good. Rotation of vertex near complete. Local
anesthesiaand episiotomy must be given.
tony 2010 mbbs 74
tony 2010 mbbs 75
others
tony 2010 mbbs 76
Pinard'sFetal
Stethoscope.
auscultation of fetalheart.
tony 2010 mbbs 77