Pengenalan Sistem Elektrik Bagi Fasiliti Kesihatan

IsmailAli675693 48 views 108 slides Mar 04, 2025
Slide 1
Slide 1 of 108
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49
Slide 50
50
Slide 51
51
Slide 52
52
Slide 53
53
Slide 54
54
Slide 55
55
Slide 56
56
Slide 57
57
Slide 58
58
Slide 59
59
Slide 60
60
Slide 61
61
Slide 62
62
Slide 63
63
Slide 64
64
Slide 65
65
Slide 66
66
Slide 67
67
Slide 68
68
Slide 69
69
Slide 70
70
Slide 71
71
Slide 72
72
Slide 73
73
Slide 74
74
Slide 75
75
Slide 76
76
Slide 77
77
Slide 78
78
Slide 79
79
Slide 80
80
Slide 81
81
Slide 82
82
Slide 83
83
Slide 84
84
Slide 85
85
Slide 86
86
Slide 87
87
Slide 88
88
Slide 89
89
Slide 90
90
Slide 91
91
Slide 92
92
Slide 93
93
Slide 94
94
Slide 95
95
Slide 96
96
Slide 97
97
Slide 98
98
Slide 99
99
Slide 100
100
Slide 101
101
Slide 102
102
Slide 103
103
Slide 104
104
Slide 105
105
Slide 106
106
Slide 107
107
Slide 108
108

About This Presentation

Nota Kursus Asas Perancangan dan Rekabentuk Fasiliti Kesihatan - Skop Kerja Elektrik oleh Cawangan Kejuruteraan Elektrik JKR


Slide Content

KURSUS ASAS PERANCANGAN DAN REKABENTUK FASILITI KESIHATAN HEAD OF DESIGN TEAM UNIT PERUNDING REKABENTUK KESIHATAN CAWANGAN KEJURUTERAAN ELEKTRIK IBU PEJABAT JKR MALAYSIA FEBRUARI 2025 SKOP KERJA ELEKTRIK DAN ICT BAGI PELAKSANAAN FASILITI KESIHATAN

KANDUNGAN PENGENALAN 01 SKOP KERJA ELEKTRIK 02 SKOP KERJA ICT 03 SKOP PERALATAN PERUBATAN KEPERLUAN RUANG BWIC 04 SKOP KERJA ELEKTRIK DAN ICT BAGI PELAKSANAAN FASILITI KESIHATAN DOKUMEN RUJUKAN ELEKTRIK 05 06

Kursus asas skop sistem elektrik ini bertujuan memberikan penerangan dan gambaran jelas terhadap asas sistem pemasangan elektrik dan ict. Menerangkan asas skop yang terlibat, pengkelasan dan kategori peralatan perubatan serta proses kerja pemasangan peralatan perubatan yang terlibat dibawah skop elektrik. Sesuatu pepasangan aset elektrik yang baik perlu merangkumi aspek โ€“ aspek keselamatan dan kelesaan kepada pengguna, praktikal, berkesan, kebolehsenggaraan dan mengikut peraturan โ€“ peraturan yang berkuatkuasa 1. PENGENALAN

1. PENGENALAN Faktor yang dipertimbangkan dalam rekabentuk: Safety Reliability Expandability Cost effectiveness Policy requirements Standards, norms and guidelines Complexity of healthcare buildings Engineering facilities to support medical requirements Requirements of patients, staff and visitors Operation & maintainability

Others Related Standard and Requirement Malaysian Standards and/or British Standards IES Standards ( International Electrotechnical Commission ) Suruhanjaya Tenaga (ST) Tenaga Nasional Berhad (TNB) Syarikat Telekom Malaysia Berhad (TM) Jabatan Bomba Dan Penyelamat Malaysia Jabatan Alam Sekitar National Nuclear Medicine Service Policy Ministry of Health Operational Policy in Nuclear Medicine Services 2018 Akta Perlesenan Tenaga Atom 1984 (Act 304) Medical Device Act 2012 (Act 737) JKR Electrical Material Approval List (JMAL)- http://jmal.jkr.gov.my/emalv3 2. DOKUMEN RUJUKAN ELEKTRIK

MS 1936:2006 Electrical Installation of Building-Guide to MS IEC 60364 MS 1979:2007 Electrical Installation of Building-Code of Practice MS IEC 60364 series Electrical Installation of Buildings MS 1525 Energy Efficiency MS IEC60364-7-710 Electrical Installation of Buildings in Medical Location MS 838: Code of Practice for Radiation Protection (Medical X-ray Diagnosis) 2. DOKUMEN RUJUKAN ELEKTRIK

JKR S pecifications L-S1 Specification of Low Voltage Internal Electrical Installation L-S2 Specification for Low Voltage Automatic Power Factor Correction Equipment L-S3 Specification for Low Voltage Underground Cable L-S4 Specification for Low Voltage Overhead Line Distribution System L-S5 Specification for Three Phase Generator Set L-S6 Specification for Acoustic Treatment for Generator Room L-S9 Specification for Lighting Protection System for Structures L-S10 Specification for 11kV Distribution Transformer 2. DOKUMEN RUJUKAN ELEKTRIK

JKR S pecifications (cont) L-S11 Specification for 11kV Medium Voltage Oil Circuit Breaker L-S12 Specification for 11kV High Voltage Ring-Main Unit Distribution Switchgea L-S13 Specification for 11kV High Cable Voltage Underground Cable L-S14 Specification for 11kV SF6 Main Unit L-S15 Specification for 11kV Metal Enclosed Switchgear L-S16 Specification for Telephone System L-S17 Specification for 11kV Dry-type Distribution Transformers L-S20 Specification for Road Lighting Installation 2. DOKUMEN RUJUKAN ELEKTRIK

Garis Panduan oleh UPE JPM Uniform Building By Law (UBBL) Panduan Teknik CKE Edisi 4 2008 Local Authority/Service Provider Requirement, Rules & Regulation Electrical System Design & Installation Guidelines For Architects & Engineers 2. DOKUMEN RUJUKAN ELEKTRIK

SKOP KERJA ELEKTRIK DAN ICT BAGI PELAKSANAAN FASILITI KESIHATAN SKOP KERJA ELEKTRIK

ELECTRICAL & ICT Medium Voltage System Low Voltage System Extra Low Voltage (ELV) Medical Equipment Group 1 Related to Electrical Building Information Modelling (BIM) Information and Communications Technologies (ICT) SKOP KERJA ELEKTRIK & ICT

SKOP KERJA ELEKTRIK PEMBAHAGIAN SISTEM ELEKTRIK

KEPERLUAN UMUM BAGI SKOP KERJA ELEKTRIK KEPERLUAN WAJIB Perunding Elektrik : Berdaftar kementerian Kewangan Malaysia Kod Bidang -330103 Kejuruteraan Elektrik Kontraktor Elektrik : Construction Industry Development Board (CIDB) dengan kategori ME dan sub bidang yang berkaitan 3. SKOP KERJA ELEKTRIK

PENGKHUSUSAN KATEGORI ELEKTRIK CIDB

PENGKHUSUSAN KATEGORI ELEKTRIK CIDB

3. SKOP KERJA ELEKTRIK 3.1 Medium Voltage (MV) System (33KV/11KV) i. MV Transformer ii. MV Switchgear iii. MV Cable iv. Earthing System Keperluan sistem adalah berdasarkan kepada anggaran beban dan cadangan pihak JKR serta semakan dengan pihak utiliti (projek konvensional). Bagi projek Reka & Bina, pihak kontraktor perlu menyemak dengan pihak utiliti serta memastikan keperluan pihak utiliti serta kos telah diambil kira di dalam cadangan petender.

Sistem Voltan Sederhana : Switchgear Alat Ubah ( Transformer ) Kabel Peralatan Pembumian 3. SKOP KERJA ELEKTRIK

Keperluan Ruang Bilik Bagi Sistem Voltan Sederhana : Switchgear Room : min.saiz (7 meter x 6 meter) Alat Ubah ( Transformer ) Room : min.saiz ( 8 meter x 6 meter ) Kabel (240/300 mm sq) Peralatan Pembumian Bilik Meter TNB : 2 meter x 2 meter Bilik-bilik yang melibatkan pihak TNB, perlu rujuk SLC (Service Level Commitment. Ketinggian ruang bilik-bilik elektrik di atas adalah 4 meter. Jenis dinding adalah clay brick double layer The system shall have two sources of incoming supply The transformers shall be of low loss cast resin dry type maintenance free 3. SKOP KERJA ELEKTRIK

3.2 Low Voltage (LV) System Skop kerja utama: Internal LV Installation External LV Installation External Lighting Uninterruptible Power Supply (UPS) Lightning Protection System and Earthing System Standby Generator Sets Surge Protection System & Voltage Stabilizing System Isolated Power System Central Electrical Monitoring System (CEMS) Etc. 3. SKOP KERJA ELEKTRIK

3.2 Low Voltage (LV) System Internal LV Installation Main Switch Board โ€“ MSB Sub switch Board โ€“ SSB Distribution Board โ€“ DB Riser 3. SKOP KERJA ELEKTRIK

3.2 Low Voltage (LV) System Electrical Switchboard designed as Separate supply system; non essential, essential, emergency Separate lighting , power, mechanical services Saiz min for MSB Room โ€“ 6 meter x 6 meter MSB Type Form 2b - Form 4b 3. SKOP KERJA ELEKTRIK

3.2 Low Voltage (LV) System Main switchboards, Sub-switch boards and distribution boards must be placed into dedicated fully enclosed electrical service rooms and not be placed in exposed areas. There shall be NO water or liquid pathway, sources and outlets (waste water pipes, chilled water pipes, hot water pipes, rain water down pipes etc) above the electrical service rooms. 3. SKOP KERJA ELEKTRIK

3.2 Low Voltage (LV) System Internal LV Installation Main Switch Board โ€“ MSB Sub switch Board โ€“ SSB Distribution Board โ€“ DB Riser SSB saiz โ€“ min 3 meter x 3 meter Riser saiz โ€“ 1 meter x 1.5 meter DB room โ€“min 3 meter x 3 meter all room โ€“ clay brick wall , 1 hour fire rated door, no ceiling and no door closer 3. SKOP KERJA ELEKTRIK

3.2 Low Voltage (LV) System Internal LV Installation Pemasangan lampu- LED, bergantung kepada jenis siling Kuantiti lampu base on lux level. Pemasangan lampu ID adalah di bawah skop Arkitek 3. SKOP KERJA ELEKTRIK

3.2 Low Voltage (LV) System Internal LV Installation Pemasangan soket โ€“ bilangan merujuk kpd kefungsian bilik dan keperluan . Colour Code: Red/Yellow/White 3. SKOP KERJA ELEKTRIK

3 . SKOP KERJA ELEKTRIK Power points and wiring accessories connected to normal supply, emergency supply and essential supply shall be of DIFFERENT COLOUR (i.e. normal supply - ivory white , essential supply -yellow , emergency supply - red). suitable types and ratings shall be provided for all equipment and plants to be installed Each equipment shall have its own power point The exact number and types of power points to be provided shall be determined by Medical Requirement

3.2 Low Voltage (LV) System Internal LV Installation Kipas - Kawasan tidak berhawa dingin - Ward Kelas 3 โ€“ regulator di bedhead ii. External LV Installation Feeder Pillar underground cable External Lighting Street light Compund light Faรงade Light 3. SKOP KERJA ELEKTRIK

External Lighting Street light Compund light Faรงade Light 3. SKOP KERJA ELEKTRIK

2.2 Low Voltage (LV) System Uninterruptible Power Supply (UPS) Saiz bilik min 3 meter x 3 meter Saiz bilik bateri min. 3 meter x 3 meter Minimum 1 jam kapasiti Sesetengah peralatan perubatan lengkap dengan UPS sendiri Ruang bilik disediakan adalah bilik UPS Switch Board 3 meter x 3 meter Bilik Batteri min. 3 meter x 3 meter

3.2 Low Voltage (LV) System Skop kerja utama: Uninterruptible Power Supply (UPS) 3. SKOP KERJA ELEKTRIK

3.2 Low Voltage (LV) System Lightning Protection System and Earthing System IEC 62305 (conventional Or Structure bonding) LPS Class hendaklah ditentukan menggunakan Risk Assessment IEC 62305-2 3. SKOP KERJA ELEKTRIK

3.2 Low Voltage (LV) System Skop kerja utama: Standby Generator Sets Saiz bilik bergantung kepada KVA genset Bilik genset mestilah mempunyai 3 free wall. (Ideal ) Kebiasan diletakkan di hujung blok bangunan or centre of load Dinding bilik genset perlu disediakan daripada double clay brick 3. SKOP KERJA ELEKTRIK

3. SKOP KERJA ELEKTRIK

3. SKOP KERJA ELEKTRIK

3. SKOP KERJA ELEKTRIK 3 .2 Low Voltage (LV) System Isolated Power System Bekalan elektrik kritikal yang membekalkan bekalan terhadap peralatan perubatan atau peralatan elektrik untuk kawasan yang kritikal iaitu berdasarkan kepada IEC 60634-7-710 berdasarkan kepada requirements of supplying power to medical locations group 2 equipment location. Memastikan bekalan elektrik kekal dibekalkan bagi kawasan yang dinyatakan tanpa berlaku gangguan kuasa seperti peralatan sokongan hayat , OT department, Intensive Care Unit atau di kawasan di mana prosedur intra jantung dilakukan. Skop kerja utama:

3 . SKOP KERJA ELEKTRIK Isolated Power System Perlu disediakan bilik yang mencukupi. Min 3mtr x 3mtr. Skop kerja utama:

3 . SKOP KERJA ELEKTRIK 3 .2 Low Voltage (LV) System Central Electrical Monitoring System (CEMS)

3 . SKOP KERJA ELEKTRIK 3 .2 Low Voltage (LV) System

Sistem Voltan Rendah: Peralatan Kabel Pembuluh / Sesalur (Konduit / Trunking) Kabel PVC digunakan. Pembuluh dan sesalur memberikan perlindungan mekanikal. Pembuluh dan sesalur terdapat dua jenis iaitu galvanised Steel (G.S) atau PVC. Sesuai semua jenis permukaan tetapi kurang sesuai dari segi astetik (tidak cantik). Oleh itu warna Sesalur / trunking perlu dicatkan sama dengan warna dinding agar nampak cantik

Sistem Voltan Rendah: Peralatan Kabel Dulang (Tray) Kabel perbagai jenis sesuai digunakan dan hanya tempat terlindung dari bahaya kerosakan mekanikal dibenarkan untuk pendawaian jenis ini. Dulang tidak mempunyai penutup dan hanya memberi sokongan kepada kabel dan bukan melindungi kabel.

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System Public Address System CCTV System Electronic Access Control System/ B oom G ate system Intruder Alarm System Audio Visual System Sound Reinforcement System Visual Projection System Master Antenna Television (MATV/SMATV) System Conference System Audio & Video Intercom System Fireman Intercom System Stage Lighting System Stage Curtain System Queue Management System Multimedia Information Display System Tie line /teleconference

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System Public Address System โ€“ 4 tingkat ke atas atau 1000 m persegi

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System CCTV System - Follow requirement CGSO - Min 5 MP , IP Based Keperluan Bilik Kawalan Keselamatan perlu disediakan

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System CCTV System

3 .3 Extra Low Voltage (ELV) System Electronic Access Control System Merujuk kepada keperluan CGSO. Asas keperluan CGSO terkini adalah CR-CR. Pengunaan push button tidak digalakan. Min Desfire EV technologies- Keperluan time attendance perlu disediakan 3 . SKOP KERJA ELEKTRIK

3 .3 Extra Low Voltage (ELV) System Intruder Alarm System Drug Store /pharmacy store 3 . SKOP KERJA ELEKTRIK

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System Audio Visual System Bilik mesyurat, bilik seminar Arkitek perlu pertimbang integrasi dengan cabinet untuk storage dan rak ELV

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System Sound Reinforcement System Visual Projection System

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System Master Antenna Television (MATV/SMATV) System

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System Conference System Perlu disediakan sekiranya melebihi 30 pax Koodinasi dengan arkitek- integrasi Bersama kabinet untuk ruang rak elv

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System Audio & Video Intercom System

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System Fireman Intercom System Perlu disediakan apabila melebihi 1000 meter persegi atau melebihi 4 tingkat

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System Stage Lighting System Stage Curtain System

3 .3 Extra Low Voltage (ELV) System Queue Management System

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System

3 . SKOP KERJA ELEKTRIK 3 .3 Extra Low Voltage (ELV) System Multimedia Information Display System

3 . SKOP KERJA ELEKTRIK 3.3 Extra Low Voltage (ELV) System (cont) Info Kiosk System

3 . SKOP KERJA ELEKTRIK 3 . 3 Extra Low Voltage (ELV) System (cont) Master Clock and Elapse Time Clock System

3 . SKOP KERJA ELEKTRIK 3 . 3 Extra Low Voltage (ELV) System (cont) Nurse Call System Nurse call systems shall be installed in all the wards, the intensive care units, the coronary care units, the special care nurseries, the isolation rooms etc.

3 . SKOP KERJA ELEKTRIK Nurse Call System The system shall be of the following features and facilities: i. Patient station with normal call cord receptacle, call reassurance lights, call/cancel button and nurse assist button located at each patient bed. ii. Staff registration, emergency call station equipped with speech facilities located at each patient bed. iii. Toilet and bath stations shall have a water resistance membrane and include a pull cord or membrane call point as appropriate, call reassurance lamp and reset button. iv. Over door light and zone light shall be installed at ward entrances, lobby, and toilet and multi bed wards and shall be clearly visible from a distance of 30 metres in the ambient light conditions.

3 . SKOP KERJA ELEKTRIK Two Way Communication System Two way radio communication system shall be installed for communication between the A&E Department and the ambulances. Now central contract โ€“ Sapura Technologies

3 . SKOP KERJA ELEKTRIK 3.3 Extra Low Voltage (ELV) System (cont) Teleconference System/Tie Line System for OT Room/Required Room/Hall

3 . SKOP KERJA ELEKTRIK 3.3 Extra Low Voltage (ELV) System (cont) Audio Recording System For Autopsy Room

SKOP KERJA ELEKTRIK DAN ICT BAGI PELAKSANAAN FASILITI KESIHATAN SKOP KERJA ICT

Data Centre Integration Telephone System Active Equipment Passive Equipment Office Automation Structure Cabling 4 . SKOP KERJA ICT IBC

4 .1 Keperluan Umum bagi Skop ICT Kontraktor WAJIB melantik; Perunding ICT: Berdaftar kementerian Kewangan Malaysia dengan kod bidang 330114-Kejuruteraan Telekomunikasi Kontraktor ICT: Construction Industry Development Board (CIDB) dengan kategori ME dan kelayakan dalam E07, E08 dan E14 . ( Rujukan klausa Appendix ICT: 1.5 dan 1.6 di dalam Need Statement ) Bagi Item Structured Cabling System (End-To-End) perlu memperoleh sijil jaminan produk & prestasi daripada pembekal kabel bagi tempoh minimum 25 tahun . (Rujuk klausa Appendix ICT: 1.2.13 di dalam Need Statement) 4 . SKOP KERJA ICT

4 .1 Keperluan Umum bagi Skop ICT Kontraktor hendaklah menyediakan sistem yang lengkap (perkakasan dan perisian) Menggunakan teknologi terkini, Sekurang-kurangnya ENAM(6) bulan sebelum tarikh pemasangan ( Rujuk Klausa Appendix ICT: 1.1.5 di dalam Need Statement ) Kontraktor hendaklah membantu pelanggan untuk berurusan dengan pihak pembekal talian (ISP dan MAMPU (120 hari sebelum CPC) untuk permohonan masuk talian/perkhidmatan. Rekabentuk Green Data Centre menggunakan teknologi hyper converged infrastructure, Smart Row Concept atau teknologi terkini. 4 . SKOP KERJA ICT

4 .2 Sistem Kabel Berstruktur ( Structured Cabling System) Horizontal Cabling CAT6A (UTP/STP) Inter Building Backbone - Fibre Optic Cable Intrabuilding Backbone (vertical & Horizontal) - Fibre Optic Cable Wireless Network Coverage ( WIFI 6 ) Fibre To The Premise (Shop Lots & Quarters) 4 .3 Perkakasan Aktif (Active Equipment For Networking System) Network Equipment (Switchers) Access Point (AP) & Wireless Controller Server (Including Servers For HIS@KKM and Related Module) Database (Appliance Based) Storage and Backup System 4 . SKOP KERJA ICT

4 .4 Sistem Telefon (Telephone System) Internal Telecommunication System (Including IPPBX & Phone Sets) External Telecommunication Works Telephone and Internet Service Subscription Lines Operator Console and PC (For Telephonist) Telecommunication Works Installation Through Walkway/ Manhole / Direct Buried (For Ducting) whichever applicable 4 . SKOP KERJA ICT

4 .5 Kerja-Kerja Integrasi Skop kerja integrasi terlibat adalah seperti berikut; Sistem ICT berkaitan termasuk rangkaian peralatan perubatan Sistem Telefon dan Telepresence (Atas talian ke luar hospital) (Rujukan klausa Appendix ICT: 8.5 di dalam Need Statement) Sistem ELV berkaitan termasuk Tie Line System yang melibatkan persidangan atas talian secara dalaman hospital Aplikasi HIS@KKM dan modul berkaitan dengan peralatan dan perubatan Lain-lain kerja integrasi yang melibatkan kefungsian operasi hspital termasuk sistem elektrikal dan mekanikal serta sistem inisiatif kerajaan yang berkaitan (Rujukan klausa Appendix ICT: 5.0 di dalam Need Statement) 4 . SKOP KERJA ICT

4 .6 Bekalan Kuasa Tanpa Gangguan (UPS) Dedicated UPS for Data Centre and/or Server Room Standalone UPS for Network Rack in TCR Standalone UPS for Desktop Computer/ Workstation Standalone UPS for IP PBX 4. 7 Office Automation (OA) System OA for Building Systems and End User Application Related Equipment OA for Administrative Works OA for Third Party Software Telepresence System 4 . SKOP KERJA ICT

4 .8 In-Building Coverage (IBC) - Cellular System Kajian kebolehalaksanaan dan sert laporan kepada Pegawai Penguasa untuk dimajukan kepada Agensi Pelanggan dan permohonan SKMM Kajian perlu dilibatkan dengan Network Facilities provider (NFP) Telco bagi kawasan projek Sekiranya dilaksanakan - Kerja-kerja pemasangan infra (Kabel/Antenna) perlu di koordinasi antara NFP Telco dengan Kerja Kontraktor Utama Insuran NFP & kelulusan semua aktivit kerja ditapak perlu melalui Pihak Kontraktor Utama sebagai Pemilik Tapak Bina 4 . SKOP KERJA ICT

4 .9 Lain-Lain Skop Kerja Data Center/ Server Room/ Telecommunication Closet Room (TCR) Facilities Application Development and Customisation Library and Facilities Security Posture Assessment (SPA) Business Continuity and Disaster Recovery Plan Computer Lab System and Facilities Training for Key-User, Application, Network and System Administrator Kerja konfigurasi (Sistem rangkaian, perkakasan, aplikasi dan lain-lain dalam skop kontrak) Kerja pengujian dan pentauliahan Kerja di bawah Tempoh Tanggungan Kecacatan (DLP) Dokumen Terbina (As-Built Documents) Daftar Aset / Inventori 4 . SKOP KERJA ICT

4 .10 Keperluan Tambahan untuk Health Facilities Project Hospital Application System Software (HIS@KKM and Related Module): HIS@KKM as based HIS System Laboratory Information System (LIS@KKM) Operation Theatre Management System (OTS@KKM) Central Sterile Supply Services Information System (CenSSIS@KKM) Radiology Information System (RIS@KKM) Picture Archiving And Communication System (PACS) Pharmacy Information Sysytem (PhIS) Blood Bank Information System v2 (iBloodLinQ) Critical Care Information System (CCIS) 4 . SKOP KERJA ICT

4 .10 Keperluan Tambahan untuk Health Facilities Project (contโ€ฆ) Hospital Application System Hardware Network Cabling Infrastructure For Medical Network Internal Telecommunication System ICT Training Room / Computer Lab and Facilities 4 . SKOP KERJA ICT

SKOP KERJA ELEKTRIK DAN ICT BAGI PELAKSANAAN FASILITI KESIHATAN SKOP PERALATAN PERUBATAN - ELE KTRIK

Equipment Group Definition Group I Requires major mechanical & electrical work related major medical equipment, coordination within building contract Supplied by contractor Eg: Dental X-Ray unit, diagnostic imaging, operating light, operating table Group II Requires major mechanical & electrical work related major medical equipment, coordination within building contract Supplied by client Eg: salvageable items from existing facility Group III 'Plug and play" equipment with normal M&E requirements easily connected to standard electrical outlets and or water source Planned and/or supplied by contractor / procure by client Eg : ultrasound machine, ventilator, ECG machine, dialysis machine, endoscopy system, etc Shall also include loose medical and non-medical equipment, medical furniture, surgical instruments Group IV Other loose items, consumables, storage implication No M&E requirements within the building contract - vehicles 5. SKOP peralatan perubatan - ELEKTRIK

5 . SKOP p eralatan perubatan - ELEKTRIK MEDI CAL EQUIPMENT GROUP 1 RELATED TO ELECTRICAL Digital General Radiography System High End Multidetector CT Scan System (64/128/256 Slices) MRI (1.5T/3.0T) System c/w all necessary accessories Digital Multipurpose C-Arm Angio Fluoroscopy Digital Mammography Tomosynthesis CBCT (Cone Beam Computed Tomography) Bone Densitometry Digital Intraoral System c/w all necessary accessories Ultrasound System (High End) Mobile Digital Radiography X-Ray Viewer/Illuminator Operating Theatre Table Operating Theatre Panel Operating Theatre Light Procedure Light/ Examination Light DDA Cabinet Etc

SURGICAL TABLE The surgical tables shall be suitable for general and specialist operations. They shall have four sections and capable of 360 degree top rotation The tables shall have full length radio translucent top, traversing top with removable lower trunk section for perennial position without lifting, extendible control handles for Trendelenburg and reverse and lateral tilt and X-ray cassette holders. The pedestal clads shall be of stainless steel. 5. SKOP peralatan perubatan - ELEKTRIK

5. SKOP peralatan perubatan - ELEKTRIK The tables shall be supplied with radio translucent anti-static mattresses. The tables shall be of electrically remote control subject to the functional requirement of Ministry of Health. The surgical tables complete with accessories and installed shall be of approved type

5. SKOP peralatan perubatan - ELEKTRIK SURGICAL LIGHT The surgical LED light system shall be suitable for all field of surgery and shall have a main light and a satellite light. The main light shall have total light intensity of not less than 160,000 lux at a distance of one metre. The lighting shall be adjustable continuously The satellite light shall have total intensity of not less than 140,000 lux at a distance of one metre. The lighting levels of the main lights shall be adjustable continuously or in several steps. The colour temperature of the light output shall be approximately 3900-4750 degree K.

5. SKOP peralatan perubatan - ELEKTRIK The independent UPS system shall be completed with maintenance free battery with a capacity of three hour at full load, no break change over switch, time elapse counter with audible and visual alarm, control panel etc. The UPS system shall be installed in separate ventilated rooms. The plant monitoring system shall continuously monitor the conditions of the battery. The surgical lights system shall integrate with camera system and link to the Auditorium/Conference room. The camera system must be detachable type. If necessary the cameras can be shared among the multiple operation theatres

5. SKOP peralatan perubatan - ELEKTRIK Examination Light Ceiling mounted examination lights of not less than 80,000 lux shall be installed at Labour room, Procedure room, Autopsy room, Treatment room, A&E Department and Critical Wards

Shall be slim and compact Automatic on/off with film insertion Supply โ€“direct terminated Uniform illumination with britghness adjustable Minimum luminance >1500 cd/m2 Minimum colour temperature >5000K Xray viewer shall be install in clinics, procedure room, treatment room, wards, seminar room, OT etc X-Ray viewer single type X-Ray viewer double type X-Ray viewer 4 in 1 type 5. SKOP peralatan perubatan - ELEKTRIK X RAY VIEWER

5. SKOP peralatan perubatan - ELEKTRIK X RAY VIEWER

5. SKOP peralatan perubatan - ELEKTRIK DDA CABINET

5. SKOP peralatan perubatan - ELEKTRIK DDA CABINET

Complete set of operation theatre panel board shall be installed in the operation theatre room and shall comprise of these features: Electrical power points Light switches Intercom clocks : Flush mounted analogue/digital X-ray viewer panel Medical gases IPS Earth stud Temperature Humidity Pressure 5. SKOP peralatan perubatan - ELEKTRIK OT PANEL

Panel boards with rear access c/w cover plate of 2.0mm or better thick plain stainless steel 316 sheet with provision opening for other services e.g. electrical, medical gases, micro and macro shock protection etc. All cabling and piping shall be properly organised and coded/labelled accordingly. Cabling in the O.T Panel shall be concealed in conduits/cable ducts/ trunkings All equipment such as light switches, clocks, medical gases, x-ray viewer, intercom, IPS, humidity controller, etc. must be housed in enclosed compartment/metal back box enclosure. 5. SKOP peralatan perubatan - ELEKTRIK

5. SKOP peralatan perubatan - ELEKTRIK GENERAL RADIOGRAPHY Conventional Analog Radiography Computed Radiography (CR) Digital Radiography (DR)

5. SKOP peralatan perubatan - ELEKTRIK

5. SKOP peralatan perubatan - ELEKTRIK

5. SKOP peralatan perubatan - ELEKTRIK

5. SKOP peralatan perubatan - ELEKTRIK DENTAL RADIOGRAPHY Orthopantomograph (OPG) Cone Beam Computed Tomography (CBCT) X-ray Unit IntraOral with Film/Digital Explore (Intra Oral)

5. SKOP peralatan perubatan - ELEKTRIK

5. SKOP peralatan perubatan - ELEKTRIK An OPG (Orthopantomagram) is a panoramic scanning dental X-ray of the upper and lower jaw. It is also sometimes called by the proprietary name Orthopantomagraph or Panorex. It shows a flattened two-dimensional view of a half-circle from ear to ear. Panoramic x-rays allow images of multiple angles to be taken to make up the composite panoramic image, where the maxilla (upper jaw) and mandible (lower jaw) are in the viewed area.

5. SKOP peralatan perubatan - ELEKTRIK

KEPERLUAN RUANG ELEKTRIK BWIC

BILIK SUIS - MAIN DISTRIBUTION BOARD (MSB) Distribution Board (MSB) msbPHYSICAL SPECIFICATION NO. PERKARA SPESIFIKASI 1. Room Dimension 6000mm (L) x 6000mm (W) 2. Door Dimension 1200mm (W) x 3000mm (H) Composite Fiber Reinforced Plastic (FRP) Lourved Double Leaf Door c/w Anti Vermin Wire Netting Aluminium Type Fixed Inside The door leaf to be out opening 3. Floor Level Different level of 50mm between finish floor level and apron or 50mm kerb across the door 4. Ramp Reinforced concrete (RC) ramp beyond the drain with 15ยบ angled steepness 5. Trench 750mm (W) x 900mm (D) c/w removable concrete cover 300mm gap between brick wall and trench (floor mounted front access SB) 6. Electric Cable Ducting 2 layers 3 nos. of 150mm dia. HDPE PN 10 pipe to be laid underground and to be extended 600mm beyond the drain 6. KEPERLUAN RUANG ELEKTRIK

BILIK SUIS (ARAS BAWAH) NO. PERKARA SPESIFIKASI 1. Room Dimension 4000mm (L) x 4000mm (W) 2. Door Dimension 900mm (W) x 2100mm (H) Double Leaf Fire Rated Door with minimum 1-hour fire rating The door leaf to be out opening 3. Floor Level Different level of 50mm between finish floor level and apron or 50mm kerb across the door 4. Trench 750mm (W) x 900mm (D) c/w removable concrete cover 300mm gap between brick wall and trench (floor mounted front access SB) 5. Electric Cable Ducting 3 nos. of 150mm dia. HDPE PN 10 pipe to be laid underground and to be extended 600mm beyond the drain 6. KEPERLUAN RUANG ELEKTRIK

BILIK SUIS (SELAIN ARAS BAWAH) NO. PERKARA SPESIFIKASI 1. Room Dimension 3000mm (L) x 3000mm (W) 2. Door Dimension 900mm (W) x 2100mm (H) Double Leaf Fire Rated Door with minimum 1-hour fire rating The door leaf to be out opening 3. Floor Level Different level of 50mm between finish floor level and apron or 50mm kerb across the door 4. Floor Opening for Riser 300mm(L) x 150mm(W) opening 6. KEPERLUAN RUANG ELEKTRIK

ELECTRICAL RISER ROOM NO. PERKARA SPESIFIKASI 1. Room Dimension 1500mm (L) x 1000mm (W) 2. Door Dimension 900mm (W) x 2100mm (H) Double Leaf Fire Rated Door with minimum 1-hour fire rating . The door leaf to be out opening 3. Floor Level Different level of 50mm between finish floor level and apron or 50mm kerb across the door 4. Floor Opening 300mm (L) x 300mm (W) shall be provided close to wall 5. Ceiling No false ceiling. Provide soffit slab c/w cement plaster and emulsion paint only Soffit slab will be provided at the top floor of multistorey building and each of single storey. 6. Room Height Minimum of 3 meters 6. KEPERLUAN RUANG ELEKTRIK

PONDOK PENGAWAL ( KEPERLUAN RUANG ELEKTRIK ) NO. PERKARA SPESIFIKASI 1. Electrical Pit 460mm (L) x 460mm (W) x 760mm (D) electrical pit shall be provided c/w removable concrete cover 150mm gap between brick wall and trench (wall mounted SB) 2. Electrical Cable Ducting 2 nos. 150mm dia. HDPE PN 10 pipe to be laid underground and extended 600mm beyond drain (if control board CL in the Pondok Pengawal. 3. Telephone Pit 460mm (L) x 460mm (W) x 760mm (D) telephone pit shall be provided close to wall c/w removable concrete cover (if ICT point required). 4. Telephone Cable Ducting 1 no. 100mm dia. GI Pipe Class B to be laid underground and extended 600mm beyond drain (if ICT point required). 6. KEPERLUAN RUANG ELEKTRIK

BILIK SUBSCRIBERS DISTRIBUTION FRAME (SDF) NO. PERKARA SPESIFIKASI 1. Room Dimension 4000mm (L) x 4000mm (W) 2. Door Dimension 900mm(W) x 2100mm(H) Double Leaf Fire Rated Door with minimum 2 hours fire rating. The door leaf to be out opening 3. Floor Level Different level of 50mm between finish floor level and apron or 50mm kerb across the door 4. Trench 1000mm(L) x 600mm(W) x 760mm(D) c/w removable concrete cover 5. Fibre Optic Cable Ducting 2 layer 2 nos. 100mm dia. GI Pipe (Class B) to be laid underground and to be extended 600mm beyond the drain 6. Other Services Requirement Air conditioning: Operating hours: 24/7 To provide at least 2 number split unit air conditioning. Alternate and auto start split unit air conditioning. Fire Fighting: Smoke Detector Portable CO2 Fire Extinguisher No Sprinkler system 6. KEPERLUAN RUANG ELEKTRIK

MAIN TELECOMMUNICATION CLOSET ROOM (MTCR) NO. PERKARA SPESIFIKASI 1. Room Dimension 4000mm (L) x 3000mm (W) 2. Door Dimension 1000mm Single Leaf Fire Rated Door with minimum 1-hour fire rating . The door leaf to be out opening 3. Floor Level Different level of 50mm between finish floor level and apron or 50mm kerb across the door 4. Telephone Pit 460mm (L) x 460mm (W) x 760mm (D) c/w removable concrete cover 5. Fibre Optic Cable Ducting 2 layer 2 nos. 100mm dia. GI Pipe (Class B) to be laid underground and to be extended 600mm beyond the drain 6. Other Services Requirement Air conditioning: For critical building or 24 hours operation complex/ building, the ducted air-conditioning shall be tapped from centralized building air-conditioning system or 2 numbers of split unit air-conditioning for continuous operation during operation hours (Alternate and auto start split unit air conditioning). For non-critical building or less than 12 hours operation complex/ building, the ducted air-conditioning shall be tapped from centralized building air-conditioning system or 1 number of split unit air-conditioning during operation hours. Fire Fighting: Smoke Detector / Heat Sensor Portable CO2 Fire Extinguisher 6. KEPERLUAN RUANG ELEKTRIK

TELECOMMUNICATION CLOSET ROOM (TCR) NO. PERKARA SPESIFIKASI 1. Room Dimension 3000mm (L) x 3000mm (W) 2. Door Dimension 1000mm Single Leaf Fire Rated Door with minimum 1-hour fire rating . The door leaf to be out opening 3. Floor Level Different level of 50mm between finish floor level and apron or 50mm kerb across the door 4. Telephone Pit 460mm (L) x 460mm (W) x 760mm (D) c/w removable concrete cover 5. Fibre Optic Cable Ducting 2 nos. 100mm dia. GI Pipe (Class B) to be laid underground and to be extended 600mm beyond the drain 6. Other Services Requirement Air conditioning: For critical building or 24 hours operation complex/ building, the ducted air-conditioning shall be tapped from centralized building air-conditioning system or 2 numbers of split unit air-conditioning for continuous operation during operation hours (Alternate and auto start split unit air conditioning). For non-critical building or less than 12 hours operation complex/ building, the ducted air-conditioning shall be tapped from centralized building air-conditioning system or 1 number of split unit air-conditioning during operation hours. Fire Fighting: Smoke Detector / Heat Sensor Portable CO2 Fire Extinguisher 6. KEPERLUAN RUANG ELEKTRIK

Mekanikal Elektrikal Sivil & Struktur Arkitek Koordinasi Sempurna Kepuasan Pelanggan Output Success KESIMPULAN