pengukuran tangki kapal tangker menggunakan metode

GilangGhufron 55 views 35 slides Jun 10, 2024
Slide 1
Slide 1 of 35
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35

About This Presentation

pengukuran tangki


Slide Content

PENGUKURAN
LEVEL TANKI
SISWANTO

PENGUKURAN
TANKI DARAT
SIS0307

DEFINISI
SIS0307
GAUGE HATCH
REFERENCE GAUGE POINT
REFERENCE GAUGE HEIGHT
STANDPIPE
DATUM PLATE
OUTAGE (ULLAGE)
INNAGE (DIP)
CUT LINE
OPENING GAUGE
CLOSING GAUGE
Datum Plate
Outage Gauge
Innage Gauge
Reference Gauge Height
Gauge Hatch
Reference Gauge Point
Standpipe
Cut line

GAUGE TAPE
STANDARD GAUGE TAPE BIASANYA DALAM UKURAN
METER ATAU KAKI (FEET) DAN PECAHANNYA.
TERDAPAT DUA TIPE, YAITU: THE INNAGE (DIP) TAPE
DAN THE ULLAGE (OUTAGE) TAPE.
UJUNG TAPE YANG BEBAS DILENGKAPI DENGAN
SNAP-CATCH YANG DIGUNAKAN UNTUK
MENEMPELKAN PEMBERAT (GAUGE BOB).
ALAT UKUR
SIS0307

FLOAT GAUGE
BERUPA FLOAT YANG BERGERAK BEBAS DI ATAS
PERMUKAAN CAIRAN, YANG DIHUBUNGKAN DENGAN
COUNTER SEBAGAI PENUNJUK LEVEL CAIRAN.
MEMILIKI KETELITIAN SEKITAR 7.5 mm.
JIKA DENSITY CAIRAN MEMILIKI
PENGARUH PADA INDIKASI
LEVEL, KOREKSI FLOAT GAUGE
HARUS DIAPLIKASIKAN.
ALAT UKUR
SIS0307

SERVO-OPERATED GAUGES
SEPERTI FLOAT GAUGES, TAPI
MENGGUNAKAN SENSOR
SEBAGAI GANTI DARI FLOAT
DAN MEMBUTUHKAN SUPLAI
DAYA LISTRIK.
ERROR YANG BERHUBUNGAN
DENGAN DENSITY SEKITAR ±
1 mm.
ALAT UKUR
SIS0307

UTI DEVICE
DI BEBERAPA TERMINAL SEKARANG MENGGUNAKAN
PERALATAN PMU YANG DISEBUT DENGAN ALAT “UTI”
(ULLAGE, TEMPERATURE AND INTERFACE) SEBAGAI
GANTI DARI GAUGE TAPE DAN BOB WEIGHTED.
ALAT UKUR JENIS INI BIASANYA DIGUNAKAN PADA
TANKER UNTUK MENGANGKUT PETROLEUM DAN
PETROLEUM PRODUCTS YANG DILENGKAPI DENGAN
INERT GAS SYSTEM.
ALAT UKUR
SIS0607

WATER GAUGE BAR
WATER GAUGE BAR ADALAH SEBUAH DIP
BOB EKSTRA -PANJANG, BIASANYA 12” ATAU
18”, BAHKAN ADA YANG SEKITAR 1 METER.
DIGUNAKAN UNTUK MENGUKUR FREE WATER
DI DASAR TANKI YANG MEMBUTUHKAN
GAUGE BOB YANG LEBIH PANJANG ATAU
BERAT UNTUK MENEMBUS KETEBALANNYA.
ALAT UKUR
SIS0307

OIL PASTE DAN WATER PASTE
SUATU PASTA YANG DIOLESKAN TIPIS -TIPIS PADA
BOB DAN ATAU TAPE.
BERUBAH WARNA SAAT BERSENTUHAN DENGAN
MINYAK (OIL PASTE) DAN AIR (WATER PASTE),
UNTUK MENUNJUKKAN LEVEL PERMUKAANNYA.
ALAT UKUR
OIL PASTE DIGUNAKAN
TERUTAMA UNTUK PETROLEUM
PRODUCTS YANG RINGAN ATAU
YANG MUDAH MENGUAP.
SIS0307

PROSEDUR PENGUKURAN
VERIFIKASI PIPELINES
SEBELUM PENGUKURAN DILAKUKAN, PIPA -PIPA YANG
DIGUNAKAN HARUS DIPASTIKAN DALAM KEADAAN
TERISI PENUH. DILAKUKAN DENGAN CARA:
-PENGISIAN (BY PUMP ATAU BY GRAVITY).
-PENEKANAN (PACKAGE).
-SIRKULASI MELEWATI PIPA.
-PENGGANTIAN ISI (DISPLACEMENT).
-PENUTUPAN KERANGAN (VALVES).
PIPELINE ADJUSTMENT (BILA ADA)
DIBERIKAN SESUAI DENGAN KUANTITAS
MINYAK YANG TERDAPAT DI DALAM PIPA.
SIS0607

-UTAMAKAN SAFETY.
-PERIKSA TANGGAL KALIBRASI
GAUGE TAPE.
-TIDAK ADA CACAT SKALA TAPE
DAN BOB WEIGHTED.
-TIDAK ADA SUMBATAN PADA
STANDPIPE.
PROSEDUR PENGUKURAN
UMUM
Datum Plate
Outage Gauge
Innage Gauge
Reference Gauge Height
Gauge Hatch
Reference Gauge Point
Standpipe
SIS0307

-CATAT REFERENCE GAUGE
HEIGHT DAN BANDINGKAN
DENGAN OBSERVED GAUGE
HEIGHT.
-JANGAN MASUKKAN TAPE KE
TANKI TERLALU DALAM
MELEBIHI REFERENCE GAUGE
HEIGHT.
PROSEDUR PENGUKURAN
UMUM
Datum Plate
Outage Gauge
Innage Gauge
Reference Gauge Height
Gauge Hatch
Reference Gauge Point
Standpipe
SIS0307

-KONTAK METAL -TO-METAL
YANG BAIK ANTARA TAPE DAN
HATCH, DAN ANTARA TAPE DAN
DATUM PLATE.
-PERIKSA PEMBACAAN TAPE
PADA REFERENCE GAUGE POINT
DAN CUT-LINE.
PROSEDUR PENGUKURAN
UMUM
Datum Plate
Outage Gauge
Innage Gauge
Reference Gauge Height
Gauge Hatch
Reference Gauge Point
Standpipe
SIS0307

-TIGA KALI PENGUKURAN, UNTUK
PENUNJUKAN BERBEDA. DAN
DUA KALI PENUNJUKAN SAMA.
-GUNAKAN TAPE GAUGE YANG
SAMA UNTUK OPENING GAUGE
DAN CLOSING GAUGE.
PROSEDUR PENGUKURAN
UMUM
Datum Plate
Outage Gauge
Innage Gauge
Reference Gauge Height
Gauge Hatch
Reference Gauge Point
Standpipe
SIS0307

-KENDURKAN TAPE DARI FRAME
ATAU CASE-NYA.
-JIKA PERLU, OLESKAN GASOLINE
PASTE TIPIS-TIPIS PADA SKALA
TAPE DI SEKITAR KETINGGIAN
PERMUKAN CAIRAN (DIP
TARGET).
PROSEDUR PENGUKURAN
INNAGE (DIPPING) GAUGE
SIS0307

-TURUNKAN BOB DAN TAPE
PERLAHAN -LAHAN HINGGA
MENYENTUH DATUM PLATE,
DAN SEGERA DIANGKAT.
-CATAT KETINGGIAN OBSERVED
GAUGE HEIGHT DAN CUT -LINE
YANG DIUKUR.
PROSEDUR PENGUKURAN
INNAGE (DIPPING) GAUGE
SIS0307

PROSEDUR PENGUKURAN
OUTAGE (ULLAGE) GAUGE
-KENDURKAN TAPE DARI FRAME
ATAU CASE-NYA.
-JIKA PERLU, OLESKAN GASOLINE
PASTE TIPIS-TIPIS PADA GAUGE
BOB (ULLAGE TARGET).
SIS0307

PROSEDUR PENGUKURAN
OUTAGE (ULLAGE) GAUGE
-MASUKKAN BOB DAN TAPE
PERLAHAN. DITURUNKAN
HINGGA PERMUKAAN
CAIRAN MENYENTUH
PERTENGAHAN BOB, DAN
SEGERA DIANGKAT.
-CATAT SKALA TAPE PADA
GAUGE POINT DAN CUT -LINE
PADA GAUGE BOB.
SIS0507

PROSEDUR YANG DIREKOMENDASIKAN UNTUK
FREE WATER GAUGING ADALAH INNAGE METHOD.
GAUGE TAPE DAN BOB DIBIARKAN TERCELUP
DALAM POSISI GAUGING:
-MINIMAL 10 DETIK, UNTUK PRODUK MINYAK
RINGAN / MUDAH MENGUAP.
-MINIMAL 60 DETIK, UNTUK CRUDE OIL DAN
PRODUK MINYAK BERAT.
PROSEDUR PENGUKURAN
FREE WATER GAUGING
SIS0307

HANYA CLEARLY WATER CUT YANG
TERDEFINISI DENGAN JELAS YANG AKAN
DIHITUNG KUANTITASNYA SEBAGAI FREE
WATER.
SPOTTING WATER CUT HARUS DICATAT,
TAPI TIDAK DINYATAKAN SEBAGAI FREE
WATER, HANYA SEBAGAI TRACES WATER.
PROSEDUR PENGUKURAN
FREE WATER GAUGING
Spotting water cut
Clearly water cut
SIS0307

CARA PENGUKURAN:
-KENDURKAN TAPE DARI FRAMENYA DAN OLESKAN
WATER PASTE SECUKUPNYA PADA BOB.
-MASUKKAN BOB DAN TAPE PERLAHAN -LAHAN
HINGGA MENYENTUH DASAR TANKI.
-BIARKAN TERCELUP MINIMAL 10 DETIK ATAU
60 DETIK, TERGANTUNG JENIS MINYAKNYA, LALU
DIANGKAT.
-CATAT KETINGGIAN MEASURED HEIGHT DAN
WATER CUT YANG TERUKUR.
PROSEDUR PENGUKURAN
FREE WATER GAUGING
SIS0507

PENGUKURAN
TANKI KAPAL
SIS0307

BEBERAPA PERISTILAHAN DALAM PENGUKURAN
TANKI DARAT JUGA BERLAKU DALAM PENGUKURAN
TANKI KAPAL, DI ANTARANYA:
-GAUGE HATCH.
-REFERENCE GAUGE POINT.
-REFERENCE GAUGE HEIGHT.
-OBSERVED / MEASURED GAUGE HEIGHT.
-OPENING GAUGE DAN CLOSING GAUGE.
-OUTAGE / ULLAGE.
-INNAGE / DIP / SOUNDING.
-DATUM PLATE, CUT, DAN LAIN -LAIN.
DEFINISI
SIS0307

BEBERAPA PERISTILAHAN DALAM PENGUKURAN
TANKI KAPAL YANG BERBEDA DENGAN TANKI DARAT,
DI ANTARANYA:
-DRAFT DAN DRAFT MARKS.
-TRIM DAN LIST
-ONBOARD QUANTITY (OBQ).
-REMAIN ONBOARD (ROB).
-WEDGE FORMULA.
-WEDGE TABLE.
DEFINISI
SIS0307

DEFINISI
SIS0307
DRAFT MARKS
FORWARD DRAFT
AFTERWARD DRAFT
MID DRAFT
TRIM
TRIM CORRECTION
LIST
LIST CORRECTION

MULTI-POINTS GAUGING
JUGA BISA DILAKUKAN
UNTUK MENGUKUR TANKI
DARAT, KHUSUSNYA PADA
PENGUKURAN FREE WATER.
Reference Gauge Point
Gauge Hatch
Oil Water Sludge
Bulkhead
Gauge Holes
DEFINISI
MULTI-POINTS GAUGING
AKTIFITAS PENGUKURAN CARGO DALAM TANKI
KAPAL MELALUI DUA ATAU LEBIH LUBANG UKUR
BAGIAN ATAS TANKI. BIASANYA UNTUK MEMASTIKAN
PENGUKURAN OBQ / ROB.
SIS0307

PERALATAN STATIS MEASUREMENT YANG
DIPAKAI DI KAPAL JUGA RELATIF SAMA
DENGAN YANG DIGUNAKAN DI DARAT, DI
ANTARANYA:
-GAUGE TAPE YANG DILENGKAPI DENGAN
BOB WEIGHTED.
-WATER GAUGE BAR.
-OIL PASTE DAN WATER PASTE.
-FLOAT GAUGE DAN “UTI”.
ALAT UKUR
SIS0507

PENGGUNAAN PORTABLE
MEASUREMENT UNIT (PMU),
DALAM HAL INI “UTI”, DAPAT
UNTUK MENGUKUR:
-LEVEL
-TEMPERATUR
-DAN FREE WATER
TELAH UMUM DILAKUKAN
OLEH KAPAL PENGANGKUT
PETROLEUM DAN PETROLEUM
PRODUCTS.
ALAT UKUR
Reference Gauge Point
Gauge Hatch
Oil Water Sludge
PMU
SIS0307

KAPAL YANG MODERN BIASANYA JUGA DILENGKAPI
DENGAN PERALATAN PENGUKURAN AUTOMATIC
TANK GAUGE (ATG / ALG) DAN AUTOMATIC
TEMPERATURE REMOTE.
DIHUBUNGKAN KE CARGO CONTROL ROOM (CCR)
UNTUK MEMONITOR KONDISI CARGO TANKS.
ALAT UKUR
SIS0607

PROSEDUR PENGUKURAN
VERIFIKASI PIPELINES
SEBELUM PENGUKURAN DI KAPAL DILAKUKAN, PIPA -
PIPA YANG DIGUNAKAN HARUS DIPASTIKAN DALAM
KEADAAN KOSONG, TIDAK ADA CAIRAN YANG MASIH
TERTINGGAL DI DALAM CARGO LINES.
PENGOSONGAN CAIRAN DILAKUKAN DENGAN
DRAINING KE CARGO TANK TERTENTU DENGAN
MEMPERTIMBANGAKAN KONDISI DRAFT KAPAL.
SIS0307

ULLAGE (OUTAGE) GAUGES BIASANYA DILAKUKAN
PADA TANKI KAPAL ATAU BARGE YANG SETENGAH
PENUH ATAU PENUH; INNAGE GAUGE DIGUNAKAN
TERUTAMA PADA BARGE.
PADA SHIP TANKS GAUGING,
BENTUK TABEL TANKI UMUMNYA
MENENTUKAN METODE GAUGING
YANG AKAN DILAKUKAN.
PROSEDUR PENGUKURAN
METODE ULLAGE DAN INNAGE
PMU
GAUGE TAPE
SOUNDING
ROD
SIS0307

SAMA DENGAN PENGUKURAN PADA TANKI DARAT,
YAITU DILAKUKAN PENGUKURAN TIGA KALI DENGAN
BEDA 3 mm.
JIKA DUA PEMBACAAN PERTAMA IDENTIK, DAPAT
DIPAKAI TANPA PERLU MELAKUKAN PEMBACAAN
TAMBAHAN.
JIKA PRODUK DALAM TANKI BERGERAK DAN SULIT
MENDAPATKAN TIGA PEMBACAAN BERBEDA DALAM 3
mm, MAKA DILAKUKAN PENGUKURAN LIMA KALI
SECEPAT MUNGKIN DAN DICATAT NILAI RATA -
RATANYA.
PROSEDUR PENGUKURAN
PENGULANGAN (REPETABILITY)
SIS0307

PENGUKURAN FREE WATER PADA MARINE VESSEL
SAMA DENGAN YANG DILAKUKAN PADA SHORE TANK.
WATER FINDING PASTE DIOLESKAN PADA BOB DARI
GAUGE TAPE, DAN INNAGE GAUGE PUN DILAKUKAN.
WATER CUT DAPAT DIBACA DARI BOB.
PROSEDUR PENGUKURAN
FREE WATER
SIS0307

OBQ / ROB BISA TERDIRI DARI AIR, MINYAK, LOT
SLOPS, OIL RESIDUE, EMULSI MINYAK/AIR DAN
NON-LIQUID MATERIAL.
PENGUKURAN OBQ DAN ROB KADANG LEBIH SULIT
DIBANDINGKAN DENGAN PENGUKURAN AFTER
LOADING ATAU BEFORE DISCHARGE APABILA ADA
OPERASI SISTEM INERT GAS DAN GAS INERTNYA.
AKIBAT PENGARUH TRIM, KADANG MATERIAL OBQ
/ ROB TIDAK MENYENTUH SELURUH DINDING
KAPAL (BULKHEAD).
PROSEDUR PENGUKURAN
OBQ / ROB
SIS0307

JIKA DIPERLUKAN:
-SAMPEL DIAMBIL DAN DI ANALISA.
-MULTI-POINT GAUGING HARUS DILAKUKAN.
-LIQUID DIHITUNG DENGAN MEMPERTIMBANGKAN
TRIM/LIST, WEDGE TABLE ATAU WEDGE FORMULA.
PROSEDUR PENGUKURAN
OBQ / ROB
SIS0307