About This Presentation
This slide aims to impart knowledge to the learners about the modelling of the power system components using per unit analysis, construction of Y bus and Z bus, different methods of power flow analysis. This also enables the students to analyse the stability of the system using different methods for...
This slide aims to impart knowledge to the learners about the modelling of the power system components using per unit analysis, construction of Y bus and Z bus, different methods of power flow analysis. This also enables the students to analyse the stability of the system using different methods for power system planning and operation.
Size: 4.69 MB
Language: en
Added: Jun 14, 2024
Slides: 14 pages
Slide Content
The power system network consists the following major components: Generator Transmission line Distribution line Load Transformer Generation: (Generator) In generation the energy is converted from one form to other forms and it voltage level be 6.6KV, 10.5KV, 11KV, 13.8KV and 15.75KV Sending end substation: (Step up transformer) The generated power can be transmitted by increasing the voltage level to 110 KV, 132KV, 220KV, 400KV and 765KV, this stage is known as primary transmission. Receiving end substation: (Step down transformer) In this stage the voltage level is reduced to 66KV, 33KV. This level is known as Secondary transmission. Structure of Power System Mr.C.Anandhakumar, AP / EEE, SRIT POWER SYSTEM ANALYSIS
Receiving end substation: (Step down transformer) In this stage the voltage level is reduced to 66KV, 33KV. This level is known as Secondary transmission. Secondary substation: (Step down transformer) In here the voltage level is reduced to 11KV, 6.6KV and 3.3KV. This level is known as Primary Distribution. From this stage we can directly supply to the industries Distribution station: (Step down transformer) In here the voltage level is reduced to 440V, and 230V. This level is known as Secondary Distribution. From this stage we can directly supply to the Commercial and Domestic loads. Service Mains: (Distributed Transformer) From here we can give supply to the various consumers. The power system operation and planning can be done in by Load flow or Power flow Analysis Fault Analysis Stability Analysis Structure of Power System Conti… Mr.C.Anandhakumar, AP / EEE, SRIT POWER SYSTEM ANALYSIS
The actual power is comprised of two components 1.Active power (resistive portion) in KW 2. Reactive power (Reactive portion) in Kvar Cumulatively know as apparent power in KVA 90 degree phase difference between KW and Kvar . Some related terms KW = KVA cos θ KVA=KW / cos θ Kvar = KVA sin θ Power Factor = cos θ Power Factor Mr.C.Anandhakumar, AP / EEE, SRIT POWER SYSTEM ANALYSIS
Per Unit System Mr.C.Anandhakumar, AP / EEE, SRIT POWER SYSTEM ANALYSIS Definition: Its is defined as the ratio of actual quantity to its base quantity expressed as a decimal. Both Actual and base values are in same units, So p.u . is dimensionless. Advantages of p.u .: It gives valuable relative magnitude information. Transformers transformation ratio is greatly simplified. Its ideal for computerized analysis and simulation of complex power system problems. Manufactures can easily specify the impedance value in p.u . The circuit laws are valid Due to p.u . representation the three phase values are easy to estimate. Note: V, I, KVA and Z are so related that the selection of base values for any two of them determines the base value of the remaining two.
POWER SYSTEM ANALYSIS
POWER SYSTEM ANALYSIS
POWER SYSTEM ANALYSIS
POWER SYSTEM ANALYSIS
POWER SYSTEM ANALYSIS
POWER SYSTEM ANALYSIS
Steps to draw the p.u . Impedance Diagram Mr.C.Anandhakumar, AP / EEE, SRIT POWER SYSTEM ANALYSIS Step 1: Choose common MVA or base MVA for the given systems. (Mostly highest generator rating is taken) Step 2: Choose an appropriate base KV for each and every section. (In any side change occurs or presence of transformer, recalculate new base KV using transformation ratio) Step 3: Calculate p.u . impedance in each section. Formula for generator, Motor and Transformer: Formula for transmission line: Step 4: Draw the impedance diagram from one line diagram.
Impedance Diagram Mr.C.Anandhakumar, AP / EEE, SRIT 6/14/2024 POWER SYSTEM ANALYSIS The impedance diagram on single phase basis under balanced operating conditions can be drawn from one line diagram. Reactance Diagram
Formation of Y-Bus by Two rule method or Inspection Method Mr.C.Anandhakumar, AP / EEE, SRIT POWER SYSTEM ANALYSIS Introduction: An interconnected power system represents an electric network with a multitude of branches and nodes. The transmission lines constitute the branches. In some of the buses power being injected into the network ( Generator Bus ) Other buses power being tapped for loads ( Load Bus ) Bus Matrix Classification: Admittance Bus ( Y Bus ) - Applications in Load flow and stability analysis. Impedance Bus ( Z bus ) – Applications in Short Circuit analysis The above said two bus matrix find the applications in power system planning and operational studies. The injected bus currents and bus voltages of a power system under steady state condition can be regulated through these matrices as
Power Flow Analysis Mr.C.Anandhakumar, AP / EEE, SRIT 6/14/2024 POWER SYSTEM ANALYSIS Classification of buses: Slack Bus or Ref Bus P-V Bus or Generator Bus P-Q Bus or Load Bus S.No Bus Quantities Specified Quantities to be specified 1. Slack bus or Ref Bus V, δ P, Q 2. P-V Bus or Generator Bus P, V Q, δ 3. P-Q Bus or Load Bus P, Q V, δ Where, P = P G - P L Q = Q G – Q L P G = Real power generated by generator connected to the bus. Q G = Reactive power generated by generator connected to the bus. P L = Real power drawn by the load. Q L = Reactive power drawn by the load.