A SMART ALERT SYSTEM TO ENSURE STERILE WORKSPACE IN A CLINICAL LABORATORY Presented By V.VINCY SHAMLEY EBEN [RA2112015010016] 2 nd year-M .Tech Department of Biomedical Engineering 9 May 2023 Dept.of Biomedical Engineering 1 GUIDED BY Dr. D. KATHIRVELU Assistant Professor Department of Biomedical Engineering
Introduction Saliva is a diagnostic fluid secreted from the salivary glands and it considers a good matrix for measuring biological activity. It is composed of 99% of water and 1% of protein, salt, and amylase, anciently doctors of traditional Chinese medicine describe saliva and blood are ‘brothers’ because it carries a wide range spectrum of genetic data. And it is one of the most accessible body fluids. the collection of samples is easy and non-invasive. It also transmits airborne diseases that spread infectious pathogens by the droplet. To avoid this type of transmitting disease a smart alert system is designed . 9 May 2023 Dept.of Biomedical Engineering 2
Aim To design a smart alert system to ensure a sterile workspace in a clinical environment using saliva and sputum as a specimen Objectives To develop a sensor module to identify the saliva and sputum droplets. To design an alert system in ensuring a sterile environment and thereby prevent transmission of communicable diseases 9 May 2023 Dept.of Biomedical Engineering 3
Methodology 9 May 2023 Dept.of Biomedical Engineering 4 Sensor to acquire the signal Amplification of the signal using OP AMP Programming a microcontroller ARDUINO NANO Using [NODEMCU]connect the system and transfer the data using WIFI
Experimental setup 9 May 2023 Dept.of Biomedical Engineering 5 An alert system is designed to detect and alert the saliva and sputum droplets
Working video 9 May 2023 Dept.of Biomedical Engineering 6
Values from the IoT [ADAFRUIT] 9 May 2023 Dept.of Biomedical Engineering 7 VALUES FOR BOTH SALIVA AND SPUTUM VALUE OF SPUTUM VALUE OF SALIVA
Performance characteristics of sputum Statistics Value 95% CI Sensitivity 60.00% 32.29% to 83.66% Specificity 93.33% 68.05% to 99.83% Positive likelihood ratio 9.00 1.30 to 62.51 Negative likelihood ratio 0.43 0.23 to 0.81 Diseases prevalence 50.00% 31.30% to 68.70% Positive predictive value 90.00% 56.44% to 98.43% Negative predictive value 70.00% 55.30% to 81.48% Accuracy 76.67% 57.72% to 90.07% 9 May 2023 Dept.of Biomedical Engineering 11
Performance characteristics of saliva Statistics Value 95% CI Sensitivity 66.67% 38.38% to 88.18% Specificity 93.33% 68.05% to 99.83% Positive likelihood ratio 10.00 1.46 to 68.69 Negative likelihood ratio 0.36 0.17 to 0.74 Diseases prevalence 50.00% 31.30% to 68.70% Positive predictive value 90.91% 59.28% to 98.57% Negative predictive value 73.68% 57.48% to 85.30% Accuracy 80.00% 61.43% to 92.29% 9 May 2023 Dept.of Biomedical Engineering 12
Thank You 9 May 2023 Dept.of Biomedical Engineering 13
9 May 2023 Dept.of Biomedical Engineering 14 TREATMENTS TO PREVENT EDENTULISM DENTURES IMPLANT ALL ON FOUR BRIDGES
9 May 2023 Dept.of Biomedical Engineering 15 TYPES OF EDENTULISM FULLY EDENTULISM PARTIALY EDENTULISM