Single effect vs double effect vam

15,284 views 11 slides May 11, 2012
Slide 1
Slide 1 of 11
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11

About This Presentation

The presentation features information about the basic difference between a single & double effect vapor absorption machines.


Slide Content

QUESTIONS TO BE ANSWERED What do the terms mean? What is the basic difference between them? How do we choose between them? What would be the difference in performance? Can you compare the feasibility of both machines? Is it feasible to design a combination of both? Summary Abbreviations Contact Details Single Effect VS Double Effect

What does the terms mean? SINGLE EFFECT: When the refrigerant and the absorbent are regenerated in a single step using a lower grade of heat source, we term that as a single stage absorption machine DOUBLE EFFECT: When the refrigerant and the absorbent are regenerated in two steps using a medium grade of heat source, we term that as a double stage absorption machine The available medium-grade heat source generates vapors of refrigerant and an absorbent solution with a intermediate concentration in the first step/stage. This generated vapors are used as a heat source in the second step/stage, where the vapors from first step/stage heat the absorbent solution with a intermediate concentration, to generate more vapors and increase the concentration of the absorbent to the required level Hence, we claim this as a dual stage/double effect concept

SINGLE EFFECT: We have only one generator to regenerate the refrigerant and absorber The heat exchanger/generator will be comparatively bigger in size, as we have less energy available in the heat source(steam/hot water), in turn, the flow will be huge. COP (Cooling Output / Heating Input (in KW or Kcal)) – 0.7 (no unit) DOUBLE EFFECT: We have two generators to regenerate the refrigerant and absorber, the HTG(High Temperature Generator) & LTG(Low Temperature Generator). As we have split the generation process and also we have a better heat source, the size of the heat exchangers/generators is pretty much less when compared to a single effect machine. COP – 1.36 to 1.43 (based on the type of heat source) What is the basic difference between them?

How do we choose between them? Generally, we suggest a vapor absorption machine, if The power cost/ running cost of electrical chiller is very high and also if the power cuts is for a longer duration, it may increase the size of DG and operating cost of the electrical chiller Waste heat recovery is available – exhaust of a DG/LP steam @ turbine outlet The steam production cost is very low. E.g., In sugar plants, they have a co-generation by using the baggasse, which is a by-product of the process The selection is mainly based on the heat source available Low grade heat source Low Temperature Hot Water – 75 to 150*C E.g. – Jacket Water from a DG, condensate return Low Pressure Steam – less than 3.5 kg/scm E.g. – Steam extracted from a Steam Turbine Medium grade heat source Medium Temperature Hot Water – 120 to 185*C E.g. – Hot water from Solar Heaters Medium Pressure Steam – Between 3.5 to 10.5 kg/scm E.g. – Steam from a boiler (maybe in excess or dedicated for VAM(if available @ low cost)) Exhaust from a DG – more that 240*C – temperature of exhaust gas

The main difference would be, that, the single effect machine requires almost twice that of a double effect machine in the case of heat input, as the amount of useful energy/enthalpy is less in a low grade energy; hence, the COP of a Single effect is almost half of that of a double-effect, but when we consider in terms of performance, there will not be any difference, as the machines are designed to provide the desired output, whatever and however maybe the energy input When the available energy for a single effect machine is on the least extreme, then we will have a considerable increase in the machine size What would be the difference in performance?

Can you compare the feasibility of both machines?

E.g., Let us consider a steam fired VAM which is designed for a range of 2.5 to 10 kg/scm. Generally, whenever there is a drop in the inlet pressure of steam, we have to increase the flow of steam, to achieve the required performance. So, for the above requirement, we should select a pipe size and a SCV, which suits the std. steam flow rate required at 2.5kg/scm pressure; but, if the inlet steam pressure rises, the generator would be receiving more energy than the required and it’s unable to design a SCV which could operate on the energy requirement of the m/c for a particular steam pressure. Hence, we cannot have a single machine which could operate for the above given conditions. When the steam pressure drops below 3.5kg/scm, we do not require the HTG, but, it is difficult to bye-pass the LiBr and steam flow, when the steam pressure drops below 3.5kg/scm. Even, if it is achieved, it is much more difficult to tune the m/c for operating at the above mentioned condition. Is it feasible to design a combination of both?

Summary We hope that, We had answered the questions which were asked initially in the most easiest and simplest way possible, so that, it would help you to take decision which best suits your requirement and process, with maximum heat recovery and minimum heat loss For anymore queries, please feel free to contact the respective regional sales person or visit www.thermaxindia.com and post your query The contact details are given below

Abbreviations VAM m/c SCV HTG LTG LiBr COP Kg/scm DG LP E.g., *C KW KCal Vapour Absorption Machine machine Steam Control Valve High Temperature Generator Low Temperature Generator Lithium Bromide Co-efficient Of Performance kilogram/square centimeter Diesel Generator Low Pressure Example degree Celsius kilo Watt kilo calories