Thin layer-chromatography

muzammilrazayousaf 1,194 views 46 slides Jan 01, 2020
Slide 1
Slide 1 of 46
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46

About This Presentation

Thin layer-chromatography


Slide Content

THIN LAYER
CHROMATOGRAPHY
MahparaGondal
Rashid LatifCollege Of Pharmacy

Learning Objective
1.State the definition of TLC
2.Explain the phases used in TLC
3.List the materials & methods used in
TLC
4.List the application of TLC
5.List the advanteges& disadavantages
of TLC

Thin Layer Chromatography
What is TLC?...
One of analysis method that is used to
identify the unknown compounds and to
determine the purity of mixture.
This method is simple, rapid and cheap
Widely used in pharmaceutical & food
stuff industry.

Introduction
TLC is a method of analysis in which the
stationary phase (a finely divided solid) is
spread as a thin layer on a rigid supporting
plate and a mobile phase, a liquid is allowed to
migrate across the surface of plate.
Supporting material made by glass, coated by solid matter act as stationary phase

TLC can be used to:
Verify a substance identity
Monitor the progress of a reaction
Determine the number of components in a
mixture.
Determine appropriate conditions for column
chromatography
Analyze the fractions obtained from column
chromatography

Theoretical Aspect
The equilibrium between the free and
absorbed states depends on three
factors:
Polarity and size of the analytemolecule
Polarity of the stationary phase
Polarity of the solvent

-A plate of TLC can be made from aluminium
or glass which is coated by a solid matter as
a stationary phase which is typically alumina
or silica gel. The covalent networks of these
absorbents create very polar materials.
-The coated material has 0.1-0.3mm in
thickness
-some of them has been added by
fluorescent indicator that will make it
florescence during the UV light exposure.

STATIONARY PHASE
Silica is commonly used as stationary
phase
The separation of sample mixture will be
depend on the polarity of sample.
Some modified silica is also used in
certain purposes.

Stationery phase Description Application
Silica gel G Silica gel with average
particle size 15µm
containing ca 13%
calcium sulfate binding
agent
Used in wide range
pharmacopoeial test
Silica gel G
254
Silica gel G with
fluorescence added
Same application with
Silica gel G where
visualization is to be
carried out under UV
light.
Cellulose Cellulose powder of less
than 30µm particle
size.
Identification of
tetracyclines

Adsorbents
Two important properties of adsorbent are its
particle size and its homogeneity.
A particle size of 10-25um is usually
recommended.
A coarse grained will not produce a satisfactory
thin layer, so for greatly enhanced resolution
should use fine-grained adsorbent.

Silica Gel
Mostcommonlyused
adsorbentintlc.
Prepared by
hydrolysisofsodium
silicatetopolysilicic
acidwhichonfurther
condensationand
polymerizationyeil
silicagelmaterial.

Silica gel matrix structure

Cont…
With regard to specific requirmentsand high purity, synthesis can
be change.
Suffix “G” is used universally to denote silica gel with gypsum
binder, namely calcium sulphatehemi hydrate (CaSO4 (0.5H2O)).
Resolution depends on particle size and particle size distribution.
TLC mean particle size 12um,
range 5-25um,
pore diameter 6nm
Commercial plates particle size 10um.

Kieselguhr(celite)
Kieselguhr(celite) are
diatomaceous earths
composed of the silica rich
fossilisedskeletal remains of
microscopic sea organisms
called diatoms.
The material has high
porosity and large surface
area , exhibits very little
absorptive properties, so
that’s why mostly use as a
support for stationary phase.
Celitewhen mixed with clay
forms fire brick which can be
crushed and sieve graded.
The firebrick has good flow
and packing properties with
an increased adsorptive
capacity.

Alumina
Alumina(Aluminiumoxide)canbesynthesizedtothesame
degreeofpurityandspecificationassilicagelbyaseriesof
non-uniformdehydrationprocessesofvariouscrystalline
modificationsofaluminiumhydroxide.
Foroptimumresultsitisnecessarytoactivatethealumina,by
heatingataspecifiedtemperature(125C-150C)foradefined
time.
Basicaluminiumoxidewhenusedwithorganiceluantswill
adsorbaromaticandunsaturatedhydrocarbons,carotenoids
steroids,alkaloidsandothernaturalproducts.

Structure of alumina

CELLULOSE
Cellulosecanbemore
accurateandprecisewhen
useintlcplates.
Celluloseuseforseparating
hydrophilicsubstancesas
comparedtosilicagelor
aluminawhichareusefor
hydrophilicsubstances.

Structure of cellulose molecule

Chemically modified cellulose
DEAEactasstronganionexchangerandcarriespositive
chargesatneutralandacidicpH.
Usedtoseparatedelicatemoleculeslikeproteinsandnucleic
acids.

MOBILE PHASE
The ability of mobile phase to move up is
depend on the polarity itself.
Volatile organic solvents is preferably used as
asmobile phase.
Mixture of two or more solvent of different
polarity give better separation than the single
solvent.

MOBILE PHASE
SOLVENT POLARITY INDEX
Butanol 3.9
Chloroform 4.1
Methanol 5.1
Ethanol 5.1
Acetonitrile 5.8
Air 9.0

MATERIALS
•TLC plate
•‘Developing container’
-chamber/ jar/ glass beaker
•Pencil
•Ruler
•Capillary pipe
•Solvents / mobile phase
-organic solvents
•UV lamp

METHOD

1. Coating Material
Silica gel, alumina, or similar material
coated on glass , metal or a plastic film
as a thin layer ( approx0.25mm).
In addition gypsum as a binder and
fluorescent powder for simplify the
visualization of spot later on.

Applicators are commercially
available which are used for
coating the plate .
Commercialyobtained with
5cm x 20cm in size.
Prepare your size when
neccesary.
2. TLC Plate Preparation

Methods for preparing layers
Pouring
Dipping
Spraying
Spreading
Precoatedplate

3. Activation of adsorbent
The plates are dried
in air and then dried
in oven at 110-140C
for 30 minutes.
On heating, the
plates are said to be
activated.

4. Capillary spotters
Place capillary tube in
burner flame, hold it
there until it softens and
start to stags.

5.Spotting’ TLC plates
Make sure that your sample is
liquifiedalready.
If not then dissolve a few
milligrams of material in a volatile
solvent create a dilute solution.
stick it using capillary pipe &
spottonto the line you have made
Smearing, smudging, and spots
that overlap will result making
identification of separated
components difficult

6.Developing Container
Preparation
Solvent is transferred
into the container with
0.5-1cm in dept from the
bottom
A piece of filter paper is
put around the inner side
of the bottle.

7.‘Develop the plate’
after spotting, put the plate inside
the chamber in the ascendant
position
Make sure that the dept of solvent
doesn’t touch the spots
Let it develop up to the 1cm from
the top of plate
After that, pull out the plate from
the chamber and let the solvent be
vaporized

8. Visualization
-The color samples are easy to be seen and no need to
use UV lamp to detect them.
-Mostly organic compounds are colorless then for the
identification of such kind of compounds need UV
lamp.

UV lamp

Cont…
Another visualizing
technique is an iodine
chamber. Iodine
sublimes and will absorb
to organic molecules in
the vapor phase.
The organic spots on the
plate turn brown and can
be easily identified.

DETECTION OF SPOT
1)Iodination-put the plate in which the spots face to
the iodine crystalland see what is the spot color
changing
2)Ninhydrin:
-specific identification of amino acid compounds.
-Ninhydrinsolution will show a purple spot when it
is sprayed to the amino acid spot.
3)KMnO
4
used to identify a reducing agent such as glucose,
fructose, vitamin C and others.
4)Alkaline tetrazoliumblue
specificalyused for corticosteroid identification

The use of Rfas separation
parameter
-The distance taken through by the solvent to move up will be
assigned as solvent front
-The distance taken through by the sample to move up will be
assign as sample front
-Rfvalue is obtained by dividing the sample front toward
solvent front
R
f= sample front
solvent front
-

Thin-Layer Chromatography:
Determination of R
fValuessolvent front
component B
component A
origin
d
S
d
B
d
A
R
fof component A =
d
A
d
S
R
fof component B =
d
B
d
S
The R
fvalue is a decimal
fraction, generally only
reported to two decimal
places
More polar!
Less polar!

Quantitative determination of known sample
-Done by scratching the spot using
spatula, and extract the compound using
the suitable solvent
-The liquid extract can be determined its
content using other method such as
spectroscopy.

Prob;emscommonly occur in TLC and how to solve
a. The spot shape is too broad
-Diameter is supposed to be < 1-2mm
b. The movement of solvent
-should be straight up
-non proportionality in stationary phase
surface will inhibit the movement of solvent
c. streaking formation
-caused by too concentrated sample

TLC Compared to Paper Chromatography
1. Precise and effective
2. More stable toward various organic
solvents

Advantages
Cheap
Simple
The developing can be monitored visually
Able to use various chemical as a detector