Total Solution for Flue Gas Analyzer Series

ahmedmagd 57 views 32 slides Jun 21, 2024
Slide 1
Slide 1 of 32
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32

About This Presentation

Total Solution for Flue Gas Analyzer Series.ppt


Slide Content

Total Solution for Flue Gas Analyzer Series

Technologies & Strengths

NDIR Dual Beam Technology
Based on dual beam design which one is reference channel and another one is test channel,
our sensors always get reference to make immediate self-adjustment to ensure the high performance.

Micro-flow NDIR Technology
Dual gas chamber design innovatively, one gas cell is injected measurement gas, another one is filled with reference
gas N2, then micro-flow infrared sensor output the signal change, comparison between measured gas variation and
reference gas signal to get the precise measurement result.

UV-DOAS Technology
Light source: Xenonflashlamp.
Gas chamber: Long optical path reflection gas chamber.
Spectrometer: UV-band spectral response is fast, measurement accuracy is high, resolution is good.

Technology Benefits
Micro-flow NDIR UV DOAS
Bestchoice for measuring SO2, NO, CO ≥ 500ppm Best choicefor measuring SO2, N0 ≤ 500ppm, dual range H2S
Water adjustment device to eliminate the impact of on
measurement
Unaffected by moisture and environmental temperature
Integrated temperature controllerto reduce environmental
temperatureaffect
Drift is less during ultra-low range measurement
Less drift & stable performance Minor vibration impact

Product Presentation

Flue Gas Analyzer Series
Gasboard-3000UV
Gasboard-3000
Gasboard-3000Plus
Gasboard-3800P
Gasboard-3800Plus
Gasboard-3800UV
Gasboard-9050
Portable Flue Gas AnalyzerOnline Flue Gas Analyzer Continuous Monitoring System
Gasboard-9081
Gasboard-90850

Online Flue Gas Analyzer Series
Gasboard-3000
Micro-flow NDIR sensor with
single gas chamber design
3 IR sensors + ECD sensor
(4 sensors at most)
Gasboard-3000Plus
Micro-flow NDIR sensor with
dual gas chambers design
Gasboard-3000UV UV DOAS sensor 2 UV sensors + ECD sensor

Online Flue Gas Analyzer
Model Gasboard-3000Plus Gasboard-3000UV
Technology Micro-flow NDIR UV DOAS
Measurement Min Range Max Range Standard Range
SO2 0-200ppm 0-5000ppm 0-100mg/m³
NO 0-200ppm 0-5000ppm 0-100mg/m³
CO 0-200ppm 0-5000ppm /
CO2 0-5% 0-25% /
O2 0-5% 0-25% 0-25%
Accuracy SO2, NO, CO, CO2: 2%FS SO2, NO: 2%FS
Repeatability ≤1%FS ≤1%FS

Performance Test
Test environment: Indoor temperature: 25±10℃Humidity: <85% RH
Test Item
Gasboard-3000Plus Gasboard-3000UV
Chinese Test StandardSO2: 0-500mg/m³
NO: 0-500mg/m³
SO2: 0-100mg/m³
NO: 0-100mg/m³
Test Result Test Result
Response Time T90 <40s T90 <29s JJF 1362 2012 6.3
Linear Error ±1.33%FS ±1%FS HJ/T76-2017 6.1.1.3
Repeatability ≤0.15% ≤0.14% HJ/T76-2017 6.1.1.2
Zero Drift / week ±1.4%FS ±1.3%FS HJ/T76-2017 6.1.1.5
Span Drift / week ±1.4%FS ±1.3%FS HJ/T76-2017 6.1.1.5

Interference Gas Test
Test environment: Indoor temperature: 25±10℃Humidity: <85% RH
Model Gasboard-3000Plus (SO2, NO: 0-500mg/m³ )
Interference GasGases
1
st
Test
(mg/m³)
2
nd
Test
(mg/m³)
3
rd
Test
(mg/m³)
Average Value
(mg/m³)
Influence
Value
N2-100%
SO2 8 6 6 7
NO 5 5 5 5
CO-305mg/m³
SO2 2 3 2 2 -0.87%
NO 4 4 3 4 -0.27%
CO2-15%
SO2 7 7 7 7 0.07%
NO 10 10 10 10 1.00%
CH4-50mg/m³
SO2 10 9 10 10 0.60%
NO 5 5 5 5 0.00%
NH3-20mg/m³
SO2 15 15 14 15 1.60%
NO 5 5 5 5 0.00%
Interference gas influence: ±1.60% FS

Interference Gas Test
Test environment: Indoor temperature: 25±10℃Humidity: <85% RH
Model Gasboard-3000UV (SO2, NO: 0-100mg/m³ )
Interference Gas Gases
1
st
Test
(mg/m³)
2
nd
Test
(mg/m³)
3
rd
Test
(mg/m³)
Average Value
(mg/m³)
Influence
Value
N2-100%
SO2 -0.5 -0.6 -0.5 -0.5
NO -0.8 -0.4 0.1 -0.4
CO-305mg/m³
SO2 -0.4 0.2 0.1 0.0 0.50%
NO 0.5 0.4 0.1 0.3 0.70%
CO2-15%
SO2 0.7 0.2 0.1 0.3 0.87%
NO 0.3 0.5 0.2 0.3 0.70%
CH4-50mg/m³
SO2 0.5 0.4 0.2 0.4 0.90%
NO 0.6 0.8 0.5 0.6 1.00%
NH3-20mg/m³
SO2 1.2 1.1 0.8 1.0 1.57%
NO 0.6 0.2 0.3 0.4 0.73%
H2S-30ppm
SO2 1.1 0.9 0.8 0.9 1.47%
NO 0.6 0.8 0.3 0.6 0.93%
Interference gas influence: ±1.57% FS

New Sensor Bench -For Easy Intergration Purpose
UV DOAS
NDIR

Micro-flow NDIR and UV DOAS Sensor Bench
Sensor bench solution for SO2, NO, CO
measurement.
Suitable for integrate into complete
instrument.

New UV DOAS Sensor Bench
UV DOAS working principle
Flashing xenon lamp acts as light source
Long-path reflection gas chamber
Stable supply voltage and current
Strong absorption signal
Flexible test range available which can less than 200mg/ m
3
with high precision
Stable performance, No cross interference between the measurement of gas
Modular design, simple structure, small size, easy integration & maintenance
Long life time, cost effective
Gasboard-2006 Series
H
2S,NO & NO
2 ,SO
2
H
2S
NO,NO
2
SO
2

New NDIR Sensor Bench
NDIR working principle
Stable and reliable infrared light source
Stable power supply voltage & current to reduce signal interference
Higher stability & high measurement accuracy
Test range can be customized
Compact appearance with modular design for easy integration & maintenance
Long life time, affordable price
Gasboard-2000 Series
CH
4, CO & NO,SO
2
CH
4
CO
NO
SO
2

Portable Flue Gas Analyzer Series
Model Gasboard-3800P Gasboard-3800Plus / Gasboard-3800UV
Instrument
Pre-treatment device

PortableFlue Gas Analyzer
Model Gasboard-3800P Gasboard-3800Plus Gasboard-3800UV
Technology Micro-flow NDIR Micro-flow NDIR UV DOAS, NDIR
Measurement
SO2 0-2000ppm 0-2000mg/m³ 0-200-2000mg/m³
NO 0-2000ppm 0-2000mg/m³ 0-200-2000mg/m³ (optional NO2)
CO 0-5000ppm 0-5000mg/m³ 0-10000mg/m³ (optional HC)
CO2 0-25%
O2 0-25%
Gas conditioning device
Self-produce
Europe BrandSampling probe
Heating tube Chinese Brand
Total weight 60 Kgs 45 Kgs

ContinuousEmission Monitoring System -Gasboard 9050

ContinuousEmission Monitoring System-Gasboard 9050
Extract sample gas directly in different temperature level.
Heating tube to avoid measurement gases loss.
Gas cooler to remove the moisture and keep sample gas dry.
Micro-flow NDIR and UV DOAS instruments are provided
in the most of projects.

Continuous Boiler Emission Monitoring System -Gasboard 9081
System Cabinet
Sampling Parts
Pre-treatment Parts

Technology:NDUV+NDIR+ECD
Measurement:SO
2,NO,CO,CO
2,HC,O
2
Features
Cyclicmonitoringofmultiplesamplingpoints.
Suitableforenvironmentswithvibration,hightemperatureandhumidity.
AutoZero&spancalibration.
7-inchtouchscreen.
Datastoredforupto1year.
SupportRS-232,RS-485,4-20mAoutput.
Optionalsoundandlightalarmoutput.
Gasboard-9085
Ship CEMS-Gasboard 9085

Project Reference

1) A.O Smith
2) University usage
3) Customer design
Project Reference

Project Reference

Customer: Power plant in Indonesia.
Application: Pollution emission monitoring, SO2, NO, CO, CO2, O2, TPF and dust.
Project Reference

Customer: Cement plant in China.
Application: Measurement CO concentration to ensure
process safety in production.
Project Reference

CEMS project in different industrial applications in China
Project Reference

Power Plant Application in China
Project Reference

Project Reference
1) Cement project.
2) CEMS installation guide.
3) Project in Pakistan.
4) Sampling probe installation.

Hubei Cubic-RuiyiInstrument Co., Ltd
Add:FenghuangNo.3 Road, FenghuangIndustrial Park
Eastlake Hi-tech Development Zone
Wuhan 430205, Hubei Province, China
Tel:027-81628831 / 027-87405251
Fax:027-87401159
Email:[email protected]
Web:www.gasanalyzer.com.cn
www.gas-analyzers.com