A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
RUN
STOP
Y1EFMAC1PLCX1X2X3
11131211CMRWDREVCM Y1
30A30B30C
FUNC
DATA
N(-)
P(+)P1
DB
GWVUL3/TL2/SL1/R
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
P R G
RESET
DISPLAY
Fe Fuji Electric
FRENIC -Mini
G
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
PAGE: 01
DATE: 01/01/2024Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
TERMINAL SYMBOL AND NAMES
Symbol Terminal NameSl. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Y1
Y1E
FMA
C1
PLC
X1
X2
X3
11
12
13
CM
FWD
REV
30A
30B
30C
Transistor output
Transistor output common
Analog output
Current input
24 volt supply for source mode
Digital input 1
Analog common
Analog voltage input
Power supply (+10v) for potentiometer
Digital common
Forward run command
Reverse run command
Relay-NO
Relay-NC
Relay-common
Digital input 2
Digital input 3
Approved by
Hafizur Rahman
VFD CONTROL AND PARAMETER
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman
L1L2L3
3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
PAGE: 02
DATE: 01/01/2024Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
E
EE
E
L1
L2
L3
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
UP/DOWN keys on keypad
RUN/STOP keys on keypad
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Keypad, Speed Adjust By Keypad
SL
01
Set Value
0
02 0
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
Voltage input to terminal [12] (0 to +10 VDC)
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
1
2
3
E
EE
E
L1
L2
L3
Potentiometer
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 03
DATE: 01/01/2024
Motor Start & Stop By Keypad, Speed Adjust By Potentiometer
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
RUN/STOP keys on keypad
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
SL
01
02 0
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
1
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
(4 to 20 mA DC)
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 04
DATE: 01/01/2024
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
RUN/STOP keys on keypad
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Keypad, Speed Adjust By Current (mA)
SL
01 2
02 0
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
Current input to terminal [C1] (4 to 20 mA DC)
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 05
DATE: 01/01/2024
Built in potentiometer (POT)
Motor Start & Stop By Keypad, Speed Adjust By Built-in Potentiometer
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
SL
01
02
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
4
0 RUN/STOP keys on keypad
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Terminal command UP/DOWN control
Freq. UP
Freq. DOWN
com
E01Terminal [X1] Function UP (Increase output frequency)
E02Terminal [X2] Function DOWN (Decrease output frequency)
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 06
DATE: 01/01/2024
4 3
4 3
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Keypad, Speed Adjust By Up Down Push Button
SL
01 7
02 0
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
RUN/STOP keys on keypad
10
11
17
18
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Terminal command FWD or REV
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 07
DATE: 01/01/2024
SSW
4 3
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
UP/DOWN keys on keypad
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire FWD), Speed Adjust By Keypad
SL
01 0
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 08
DATE: 01/01/2024
SSW
4 3
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
UP/DOWN keys on keypad
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire REV), Speed Adjust By Keypad
SL
01 0
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Terminal command FWD or REV
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 09
DATE: 01/01/2024
STP
2 1
STT
4 3
COM
E01Terminal [X1] Function Enable 3-wire operation
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
UP/DOWN keys on keypad
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Three Wire FWD), Speed Adjust By Keypad
SL
01 0
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
10 6
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 10
DATE: 01/01/2024
STP
2 1
STT
4 3
COM
Terminal command FWD or REV
E01Terminal [X1] Function Enable 3-wire operation
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
UP/DOWN keys on keypad
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Three Wire REV), Speed Adjust By Keypad
SL
01 0
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
10 6
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
1
2
3
E
EE
E
L1
L2
L3
Voltage input to terminal [12] (0 to +10 VDC)
POT
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 11
DATE: 01/01/2024
Terminal command FWD or REV
SSW
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire FWD), Speed Adjust By Potentiometer
SL
01 1
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
1
2
3
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 12
DATE: 01/01/2024
POT
SSW
Voltage input to terminal [12] (0 to +10 VDC)
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire REV), Speed Adjust By Potentiometer
SL
01 1
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
1
2
3
E
EE
E
L1
L2
L3
Voltage input to terminal [12] (0 to +10 VDC)
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 13
DATE: 01/01/2024
POT
STP
STT
COM
Terminal command FWD or REV
E01Terminal [X1] Function Enable 3-wire operation
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Three Wire FWD), Speed Adjust By Potentiometer
SL
01 1
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
10 6
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
2 1
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
1
2
3
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 14
DATE: 01/01/2024
POT
STP
STT
COM
Voltage input to terminal [12] (0 to +10 VDC)
Terminal command FWD or REV
E01Terminal [X1] Function Enable 3-wire operation
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Three Wire REV), Speed Adjust By Potentiometer
SL
01 1
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
10 6
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
2 1
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 15
DATE: 01/01/2024
(4 to 20 mA DC)
Current input to terminal [13] (4 to 20 mA DC)
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire FWD), Speed Adjust By Current (mA)
SL
01 2
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
SSW
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 16
DATE: 01/01/2024
(4 to 20 mA DC)
SSW
Current input to terminal [13] (4 to 20 mA DC)
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire REV), Speed Adjust By Current (mA)
SL
01 2
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Current input to terminal [13] (4 to 20 mA DC)
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 17
DATE: 01/01/2024
(4 to 20 mA DC)
STP
STT
COM
Terminal command FWD or REV
E01Terminal [X1] Function Enable 3-wire operation
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Three Wire FWD), Speed Adjust By CURRENT (mA)
SL
01 2
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
10 6
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
2 1
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 18
DATE: 01/01/2024
(4 to 20 mA DC)
STP
STT
COM
Current input to terminal [13] (4 to 20 mA DC)
Terminal command FWD or REV
E01Terminal [X1] Function Enable 3-wire operation
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Three Wire REV), Speed Adjust By CURRENT (mA)
SL
01 2
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
10 6
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
2 1
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 19
DATE: 01/01/2024
Built in potentiometer (POT)
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire FWD), Speed Adjust By Built in Potentiometer
SL
01 4
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
SSW
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 20
DATE: 01/01/2024
SSW
Built in potentiometer (POT)
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire REV), Speed Adjust By Built in Potentiometer
SL
01 4
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 21
DATE: 01/01/2024
STP
STT
COM
Built in potentiometer (POT)
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Three Wire FWD), Speed Adjust By Built in Potentiometer
SL
01 4
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
E01Terminal [X1] Function Enable 3-wire operation10 6
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
2 1
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 22
DATE: 01/01/2024
STP
STT
COM
Built in potentiometer (POT)
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Three Wire REV), Speed Adjust By Built in Potentiometer
SL
01 4
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
E01Terminal [X1] Function Enable 3-wire operation10 6
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
2 1
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Freq. UP
Freq. DOWN
com
SSW
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 23
DATE: 01/01/2024
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire FWD), Speed Adjust By Up Down Push Button
SL
01 7
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
E01Terminal [X1] Function UP (Increase output frequency)
E02Terminal [X2] Function DOWN (Decrease output frequency)
10
11
17
18
Terminal command UP/DOWN control
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
4 3
4 3
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Freq. UP
Freq. DOWN
com
SSW
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 24
DATE: 01/01/2024
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire REV), Speed Adjust By Up Down Push Button
SL
01 7
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
E01Terminal [X1] Function UP (Increase output frequency)
E02Terminal [X2] Function DOWN (Decrease output frequency)
10
11
17
18
Terminal command UP/DOWN control
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
4 3
4 3
4 3
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Freq. UP
com
Freq. DOWN
STP
STT
com
E03Terminal [X3] Function Enable 3-wire operation
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 25
DATE: 01/01/2024
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Three Wire FWD), Speed Adjust By Up Down Push Button
SL
01 7
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
E01Terminal [X1] Function UP (Increase output frequency)
E02Terminal [X2] Function DOWN (Decrease output frequency)
10
11
17
18
Terminal command UP/DOWN control
12 6
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
4 3
4 3
4 3
2 1
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
Freq. UP
com
Freq. DOWN
STP
STT
com
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 26
DATE: 01/01/2024Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
E03Terminal [X3] Function Enable 3-wire operation
Terminal command FWD or REV
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Three Wire REV), Speed Adjust By Up Down Push Button
SL
01 7
02 1
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
E01Terminal [X1] Function UP (Increase output frequency)
E02Terminal [X2] Function DOWN (Decrease output frequency)
10
11
17
18
Terminal command UP/DOWN control
12 6
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
4 3
4 3
4 3
2 1
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
com
SSW-1
SSW-2
SSW-3
3 4
3 4
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 27
DATE: 01/01/2024
E01Terminal [X1] Function Select multistep frequency (SS1)
E02Terminal [X2] Function
E03Terminal [X3] Function
Select multistep frequency (SS2)
Select multistep frequency (SS4)
C05Multistep Frequency 1 0.00 Hz to 400.00 Hz
C06Multistep Frequency 2
C07Multistep Frequency 3
C08Multistep Frequency 4
C09Multistep Frequency 5
C10Multistep Frequency 6
Multistep Frequency 7C11
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
UP/DOWN keys on keypad
RUN/STOP keys on keypad
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Keypad, Speed Adjust By Multistep Frequency
SL
01 0
02 0
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
10
11
12
13
14
15
16
17
18
19
0
1
2
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
5
10
15
20
25
30
35
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
3 4
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
com
SSW-1
SSW-2
SSW-3
3 4
3 4
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 28
DATE: 01/01/2024Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
3 4
1
2
3
POT
E01Terminal [X1] Function Select multistep frequency (SS1)
E02Terminal [X2] Function
E03Terminal [X3] Function
Select multistep frequency (SS2)
Select multistep frequency (SS4)
C05Multistep Frequency 1 0.00 Hz to 400.00 Hz
C06Multistep Frequency 2
C07Multistep Frequency 3
C08Multistep Frequency 4
C09Multistep Frequency 5
C10Multistep Frequency 6
Multistep Frequency 7C11
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Keypad, Speed Adjust By Multistep Frequency
SL
01 1
02
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
10
11
12
13
14
15
16
17
18
19
0
1
2
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
5
10
15
20
25
30
35
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
Voltage input to terminal [12] (0 to +10 VDC)
0 RUN/STOP keys on keypad
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
Param.
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
E
L1
L2
L3
com
SSW-1
SSW-2
SSW-3
3 4
3 4
3 4
SSW
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 29
DATE: 01/01/2024
4 3
E01Terminal [X1] Function Select multistep frequency (SS1)
E02Terminal [X2] Function
E03Terminal [X3] Function
Select multistep frequency (SS2)
Select multistep frequency (SS4)
C05Multistep Frequency 1 0.00 Hz to 400.00 Hz
C06Multistep Frequency 2
C07Multistep Frequency 3
C08Multistep Frequency 4
C09Multistep Frequency 5
C10Multistep Frequency 6
Multistep Frequency 7C11
3
E
Parameter Name DescriptionParam.
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire FWD), Speed Adjust By Multistep Frequency
SL
01
02
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
10
11
12
13
14
15
16
17
18
19
0
1
2
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
5
10
15
20
25
30
35
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
(4 to 20 mA DC)
Current input to terminal [13] (4 to 20 mA DC)
Terminal command FWD or REV
2
1
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
24V DC
0V DC
com
SSW-1
SSW-2
SSW-3
3 4
3 4
3 4
STP
2
3
4
STT RLY
9
5
RLY
L1
L2
L3
L1L2L3
UVW
30A
30B
30C
A
B
C
D
E
F
G
HH
E
F
G
A
B
C
121110987654321
1211109876
D
1 2 3 4 5
X1
PLC
C1
Y1
Y1E
FMA
11
13
12
X2
X3
11
CM
REV
FWD
CM
TYPE:FRN0011C2S-4A
SER.NO.T15A491A0003IJ
Fe Fuji Electric
FRENIC -Mini
RUN
STOP
FUNC
DATA
P R G
RESET
DISPLAY
E
EE
Approved by
Hafizur Rahman
VFD Control and Parameter
Designed by
Kafayet Ullah Munna
Checked by
Hafizur Rahman PAGE: 30
DATE: 01/01/2024Abul Khair Condensed Milk & Beverage Ltd
Chattrogram - Bangladesh
1
14
13
12
8
E01Terminal [X1] Function Select multistep frequency (SS1)
E02Terminal [X2] Function
E03Terminal [X3] Function
Select multistep frequency (SS2)
Select multistep frequency (SS4)
C05Multistep Frequency 1 0.00 Hz to 400.00 Hz
C06Multistep Frequency 2
C07Multistep Frequency 3
C08Multistep Frequency 4
C09Multistep Frequency 5
C10Multistep Frequency 6
Multistep Frequency 7C11
3
E
Parameter Name Description
F01
F02
F03
F04
F05
Frequency Command
Operation Method
Maximum Frequency
Base frequency
F07 Acceleration Time
F08 Decleration Time
P02 Rated capacity
Motor
Power
Voltage
Current
Frequency
1.50 KW
230 V
5.80 A
50 HZ
Motors Nameplate Data
Motor Start & Stop By Terminal (Two Wire REV), Speed Adjust By Multistep Frequency
SL
01
02
03 50
04 50
05 Rated Voltage 230 Motors Nameplate
Motors Nameplate
06 6
07 6
08
09
1.50Motors Nameplate
P03Rated Current 5.80Motors Nameplate
10
11
12
13
14
15
16
17
18
19
0
1
2
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
0.00 Hz to 400.00 Hz
5
10
15
20
25
30
35
25.0 Hz to 400.0 Hz
0.00 s to 3600 s
0.00 s to 3600 s
Terminal command FWD or REV1
Built in potentiometer (POT)4
Set Value
10 E27Terminal [30A/B/C] Func. 0 Inverter Running
X1
X2
HL1
N
E
Param.