Shanghai, 2005-02-28 1
EVALUTION OF DOSSIERS IN WHO-
PREQUALIFICATION PROJECT
MULTISOURCE HIV/AIDS-DRUGS
Evaluation of
bioavailability/bioequivalence data
Based, with some changes on a presentation by Anna-Karin
Hamberg
Medical products agency, Sweden
Presented by
Hans Kemmler
Consultant to WHO
(Clinical Reviewer, Swissmedic, Switzerland)
Shanghai, 2005-02-28 2
Why do we need
Bioequivalence studies?
No clinical studies have been performed in
patients with the Generic Product to support
its Efficacy and Safety.
With data to support similar in vivo
performance (= Bioequivalence)
Efficacy and Safety
data can be extrapolated from the Innovator
Product to the Generic Product.
Shanghai, 2005-02-28 3
Overview
Definition of some important
Bioequivalence [BE] terms
Key issues in the WHO Manual Annex 3
“Guidelines on Requirements to
Establish Interchangeability”
Major Deficiencies in BE-Studies
identified within the WHO Procurement,
Quality and Sourcing Project: HIV/Aids
Drugs
Shanghai, 2005-02-28 4
Overview
A Note on Choice of Reference
Products
Present new WHO Template for
Assessment of Bioequivalence data
Shanghai, 2005-02-28 5
Bioavailability
“ .. the extent and the rate at which a
substance or its active moiety is delivered
from a pharmaceutical form and becomes
available in the general circulation.”
Reference:
intravenous administration = 100% bioavailability
Shanghai, 2005-02-28 6
Plasma concentration time
profile
C
max
T
max
AUC
time
concentration
Shanghai, 2005-02-28 7
Important Pharmacokinetic
Parameters
AUC: area under the concentration-time
curve measure of the extent of
bioavailability
C
max
: the observed maximum concentration of
drug measure of both the rate of
absorption and the extent of bioavailability
t
max
: the time after administration of drug at
which C
max
is observed measure of the rate
of absorption
Shanghai, 2005-02-28 10
Pharmaceutical Equivalents
contain the same amount of the same active
substance in the same dosage form
meet the same or comparable standards
intended to be administered by the same
route
Pharmaceutical equivalence by itself does not
necessarily imply therapeutic equivalence
Shanghai, 2005-02-28 11
Pharmaceutical Equivalents
Possible Differences
Drug particle size
Excipients
Manufacturing
Equipment or
Process
Site of manufacture
Test Reference
Could lead to differences in product performance in vivo
Possible Bioinequivalence
Shanghai, 2005-02-28 12
Bioequivalence
Two products are bioequivalent if
they are pharmaceutically equivalent
bioavailabilities (both rate and extent) after
administration in the same molar dose are
similar to such a degree that their effects
can be expected to be essentially the same
Shanghai, 2005-02-28 13
Therapeutic equivalence
Two products are therapeutically equivalent if
pharmaceutically equivalent
their effects, with respect to both efficacy and
safety, will be essentially the same as derived
from appropriate studies
–bioequivalence studies
–pharmacodynamic studies
–clinical studies
–in vitro studies
Shanghai, 2005-02-28 14
Interchangeable
pharmaceutical products
If a product is demonstrated to be
therapeutically equivalent to a reference
product, then the products are considered
interchangeable.
Shanghai, 2005-02-28 15
Bioanalytical Method Validation
Quantitative determinations of drugs
in biological samples, such as blood
or plasma, play a significant role in
evaluation and interpretation of
bioequivalence data.
Shanghai, 2005-02-28 16
Bioanalytical Method Validation
Essential to use a well-characterised
and fully validated analytical method
to yield reliable results.
Shanghai, 2005-02-28 17
Bioanalytical Method Validation
Method Validation should include
–Accuracy
–Precision
–Sensitivity
–Specificity
–Recovery
–Stability
Shanghai, 2005-02-28 18
Bioanalytical Method Validation
Accuracy
Closeness of determined value to the
true value.
The acceptance criteria is mean value
15% deviation from true value.
At LOQ, 20% deviation is acceptable.
Shanghai, 2005-02-28 19
Bioanalytical Method Validation
Precision
The closeness of replicate
determinations of a sample by an
assay.
The acceptance criteria is 15% CV.
At LOQ, 20% deviation is acceptable.
Shanghai, 2005-02-28 20
Bioanalytical Method Validation
Sensitivity
The limit of quantitation (LOQ)
is the lowest concentration
which can be measured with
acceptable accuracy and
precision.
Shanghai, 2005-02-28 21
Bioanalytical Method Validation
Specificity (selectivity)
Ability of the method to measure
only what it is intended to measure
in the presence of other components
in the sample. Blank samples of the
biological matrix should be tested
for interfering peaks.
Shanghai, 2005-02-28 22
Bioanalytical Method Validation
Recovery
The extraction efficiency of an analytical
process, reported as a percentage of the
known amount of an analyte carried
through the sample extraction and
processing steps of the method. Recovery
does not have to be 100%, but the extent of
recovery of an analyte and of the internal
standard should be consistent.