Electrical Safety - Safety Management Training

nikkithedestroyer 1 views 34 slides Oct 15, 2025
Slide 1
Slide 1 of 34
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34

About This Presentation

Electrical Safety


Slide Content

Global Developments
in
Electrical Safety
Electrical Safety week, ICF,
Perambur, 13th June 2003
P.G. Sreejith
Cholamandalam AXA Risk Services Ltd.
www.cholaaxa.com
E-Mail: [email protected]

Electrical Accidents-Statistics

•India
•Almost 12 people die due to electrocution every
day (Source -NCRB)
• 42 % of total fires occur due to electrical
sources (Source -OISD)
• 8% deaths that occur in factories are due to
electricity

Electrical Accidents-Statistics

United States
• 25% of all fires occur due to electricity
• 411 deaths from job related electrical accidents
per year (NIOSH)
• Electrocution - the fifth leading cause of death
(1982 - 1990) NIOSH

Present Status - ES-India
•ES Awareness is slowly growing
•Use of HRCs /RCCBs is the rise, finer details are yet to be
understood by many
•More ES workshops / seminars are conducted in India
•Statutory regulations are enforced strictly (Karnataka,
Delhi - Use of RCCBs mandatory in residential buildings)
•Many industries are re-aligning their Electrical practices
based on international standards (NFPA, IEEE, etc.)

Various ES Standards / organizations-US
• NFPA - NEC (1897)
•NESC (1913), from IEEE
•NIOSH (Research example: development of voltage
detector that will signal the person if he gets close to
live power)-1970
• OSHA (1970)
•NFPA 70 E & B (1979) -approved by OSHA
•Electrical Trauma Centre, Chicago (1990)
•NESF(1994), by UL, NFPA, NEMA, CPSC

Global Developments in Electrical Safety
• Electrical Safety Products
•ES Auditing Techniques
•ES System Certifications
• Electrical Risk-Based Maintenance System
•Electrical RM Programme

ES Products...
• Residual Current-Operated Circuit Breakers (RCCBs)
•Arc Fault Current Interrupters (AFCIs)
• Glowing Connection Detector (GCDs)
•Infra-Red Hotspot Detection Tool
•Thermography Surveys

ES Products
• Automatic Defibrillators
•Complete Home ES Kit
• Automatic Fire Detection & Extinguishing System

•Electrical Product Safety Recalls
•Linear Heat Sensing Cables (LHSC)

GFCIs & RCCBs
•GFCIs - 5 mA, RCCBs - 30, 100, 300 mA
•Delayed tripping RCCBs (200 mS)

AFCIs
• Arcs - temperatures up to 20,000 degree C, Sun’s
outer temperature- 5000 degree C
•No material on earth can withstand arc temperature
•RCCBs cannot detect arcing faults
•AFCIs - the innovative ES device after RCCBs
•AFCIs detects arcing waveforms and trips
•AFCIs - mandatory in all US homes from 2002 January
onwards

Arcing types

Arcing Waveforms

A loose wire at one terminal
of a light bulb.
Arcing generated by a loose
wire at a screw terminal.

GCDs
• GCs are fires waiting to happen
•Loose connections at socket terminals will cause
glowing connections
•Use of GCDs- recommended by Forensic engineers
•Glowing connections -will not detected by fuses,
MCBs, RCCBs, AFCIs
•GCDs operate at 83 degree C
•Glowing connection hazards were detected by a UL
study

Infra-Red Hotspot Detector
• Used as part of effective EPM
•Hotspot surveys on critical, high capacity motor
terminations, measurement of continuously running
critical motors
•Uses infra-red technology, with laser sighting
•Does not penetrate glass, plastic
• Interpretation of readings - very critical

HFFR Cables
• Halogen-Free Fire Retardant cables
•Emits very low smoke, compared to PVC & even FRLS
cables
• Increasingly Used by many instead of FRLS (Fire
Retardant low Smoke) cables

Thermography Surveys
• Part of predictive maintenance
•In the De-Terrified scenario, may be offered by general
insurance companies
•Identification of potential survey points / equipment and
interpretation - very crucial
•NFPA 70 E recommends Thermographic surveys

Automatic External Defibrillators (AED)
•250,000 deaths every year due to sudden cardiac
arrest
•AEDs - to be part of Emergency Medical Kit
•For every minute that passes w/o defibrillation, the
chances of survival decreases by 10%
•Has a voice prompt, cost USD 3000/-
•UK - not a legal requirement, but a Statutory
requirement in US
•No legal liability for deaths involving the use of
AEDs

Linear Heat Sensing Cables
• Advantageous than detectors, more effective
•LHSC applications:
•Cable trays in cable galleries
•Transformers
•Switch gears

Automatic Fire D&E System

Fire Trace - local flooding application inside electrical
switch gears / power panels- detects heat and the heat
-sensitive tube punctures, letting out Ozone-friendly
fire extinguishing gas

More ES Products
•Non-Contact type voltage detector (magnetic field)
•Plug-In Wiring Checker (detects 14 wiring defects,
ideal for testing sockets, BS 1363, faulty N, missing E,
reverse P& N)
•Videoscanner, Metalliscanner (detects metallic pipes,
conduits, rebar, within 15” concrete)

Home ES Kit
• Cutler Hammer, USA offers Home Safety kit,
comprising of:
•Surge protector
•GFCI
•AFCI
•MCBs

Electrical Product Safety Recalls
•Part of product liability
•Electrical products recalled:
•Power tool battery packs (defective battery
fixings)
•Building Wire (wrong earth wire identification)
•IBM 15” PC monitor( overheating of electrical
components resulting in smoke)
• 3 pin plugs (improper earth connection)

ES Auditing Techniques
• Electrical Risk Assessment using Semi-Quantitative
Risk Ranking (SQRR) technique
• Usage of software to carry out Lightning Risk
Assessment, Hazardous Area Classification
• Electrical HAZOP (Electrical Hazard & Operability)
studies
•Electrical Hazard Spotting Exercises

Electrical Risk Assessment (SQRR
Technique)
Risk Ranking based on severity, probability

High Risk- Statutory Non-compliance, F&E hazards,
Shock hazards, Risks that could result in immediate
threat to life & property. Immediate correction
Medium Risk - Maintenance flaws,Operational issues-
correction at the next available opportunity.
Low Risk - Mainly improvement measures, long term
implementation

ES System Certification
• Integrated Occupational Health & Safety Management
System certification (OHSAS 18001)
•ATEX Certification (applicable to manufacturers / user
industries, applicable in EU, mandatory by July 2003)
• UL certification for Lightning Protection (based on NFPA
780 standard)
•Electrical Fires & Forensic Investigations

Electrical Fires & Forensic Investigations
• Forensic studies are commissioned by insurance
companies in Japan, US, etc.
•Product liability claims
•Reconstruction of electrical fires
•Major electrical equipment failures (MBD)
•Investigation of Transformer fires
•Bus duct failures

Electrical Risk- Based Maintenance
• Risk & Reliability based Maintenance Schedules
•Re-Aligning the Electrical Systems in Line with Specialized
International Standards to Improve electrical Safety (IEEE,
NFPA 70B)
• Usage of Tools / Condition Monitoring Methods to have
Effective Predictive Maintenance System

Lightning -Common Myths
Lightning strikes only the tall objects/ structures
Lightning does not strike the same object twice
You are safe inside a metal bodied car during
lightning!

Electrical Risk Management
Programme
• Identification of electrical hazards
•Risk Ranking (SQRR of electrical risks)
•Risk Mitigation / Control using ALARP (As Low As
Reasonably Practicable) principle
Continuous electrical hazard identification

HAC Risk Assessment
•Extension to the existing HAC approach
•Would be part of future European legislation
• Presence of ignition sources considered in HAC
• With this new HAC approach, the equipment
optimization is expected to increase

New HAC-based Risk
Assessment Matrix
Grade of ReleaseContinous Frequent Infrequent Very Infrequent
Continous Unacceptable Unacceptable
unless low
consequences
Acceptable
(e.g. Ex i
apparatus)
Primary Unacceptable Unacceptable Risk Assessment
required-look at
consequences
Acceptable (e.g.
Ex d apparatus )
Secondary Risk Assessment
required-look at
consequences but
probably
unacceptable
Risk Assessment
required-look at
consequences but
Acceptable
(E.g. Ex n
apparatus)
Acceptable
Non-Hazardous Acceptable but
examine
catastrophic
releases
Acceptable but
examine
catastrophic
releases
Acceptable Acceptable
Grade of Ignition

Risk-Based ES Audit
Electrical Safety Audits focussed on potential
risks
 The audit methodology designed to identify all
potential electrical risks (FTA, ETA, HAZOP,
etc.)
Semi-Quantification of events using available
failure data

Wrap-Up
•Need for Electrical Safety is universal
•ES awareness is increasing
•Partnership between regulators, employers,
manufacturers- growing
•Many injuries are prevented
•Learning from experience- very essential
•Innovative ES devices are being used by people
Much More to be done in the field of ES
in India!!

Technology can afford to get obsolete
but not a technocrat!!
www.cholaaxa.com
Tags