Infrared Spectroscopy PPT, Principle, Instrumentation

DrVijayaBarge 360 views 49 slides Mar 06, 2024
Slide 1
Slide 1 of 49
Slide 1
1
Slide 2
2
Slide 3
3
Slide 4
4
Slide 5
5
Slide 6
6
Slide 7
7
Slide 8
8
Slide 9
9
Slide 10
10
Slide 11
11
Slide 12
12
Slide 13
13
Slide 14
14
Slide 15
15
Slide 16
16
Slide 17
17
Slide 18
18
Slide 19
19
Slide 20
20
Slide 21
21
Slide 22
22
Slide 23
23
Slide 24
24
Slide 25
25
Slide 26
26
Slide 27
27
Slide 28
28
Slide 29
29
Slide 30
30
Slide 31
31
Slide 32
32
Slide 33
33
Slide 34
34
Slide 35
35
Slide 36
36
Slide 37
37
Slide 38
38
Slide 39
39
Slide 40
40
Slide 41
41
Slide 42
42
Slide 43
43
Slide 44
44
Slide 45
45
Slide 46
46
Slide 47
47
Slide 48
48
Slide 49
49

About This Presentation

Infrared Spectroscopy PPT


Slide Content

INFRARED SPECTROSCOPY PR E SENT E D B Y : DR .VI J A Y A BA R GE ( Vice Principal & Professor) Pune District Education Association’s Shankarrao Ursal College of Pharmaceutical Sciences & Research Centre.

LEARNING OBJECľIVES Afteí completing this sub-unit the students should be able: 1. ľo study the theoíy of Infíaíed absoíption spectíoscopy . 2.ľo study the modes of vibíations in IR spectíoscopy 3.ľo study the factoís affecting vibíations in IR spectíoscopy 4.ľo study the instíumentation involved in IR spectíoscopy 5.ľo study the applications of IR spectíoscopy

ELCETROMAGNETIC SPECTRUM The electromagnetic ( EM ) spectrum is the range of all types of EM radiation

IR SPECTROSCOPY

IR REGIONS

MOLECULAR VIBRATIONS

W agg i ng;

A fundamental band is the spectral band that occurs in a vibrational spectrum of a molecule when the molecule makes a transition from the ground state (v=0) to the first excited state (v=1) An overtone band is the spectral band that occurs in a vibrational spectrum of a molecule when the molecule makes a transition from the ground state (v=0) to the second excited state (v=2) F U N D AME N T AL A N D OVE R T ONE B A N D S

DEGREE OF FREEDOM

The IR spectrum is a plot of % transmittance (or absorbance) of the radiation through the molecule versus wave number of the radiation

IR INSTRUMENTATION

SO U RCE

MONOCHROMATORS

SAMPLE CELLS

Sampling of solids

Solid films

Press pellet technique

Sampling of liquids

Sampling of gases

DETEC T ORS

Thermocouple A thermocouple consists of a pair of junctions. Two junctions are formed by connecting two pieces of a similar metal like bismuth ( Bi) to either ends of a dissimilar metal such as antimony (Sb) or a semiConducting alloy. One junction is used as a reference junction and another junction is used as a detector junction. A potential difference is developed across the two junctions depending on the difference between their temperatures.

Temperature of a reference junction need not be kept constant since the difference between the temperatures of the junctions is required to determine the intensity of a signal. Still, most of the times, to get the accurately measurable difference between the temperatures of the two junctions, the temperature of the reference junction is kept more or less constant by cooling it in ice. The greater the difference in the temperatures of the two junctions, the higher is the sensitivity of the method and the higher is the accuracy of the measurement. The reference junction has relatively large heat capacity. i.e. a large amount of heat is associated with the minute change in the temperature of the reference junction. 2. A detector junction A detector junction or the junction for detecting intensity of IR radiation transmitted after the interaction with an analyte should be designed so as to have complete absorption of heat from the IR radiation incident on it. Hence, special care is taken to design this junction from fine wires of platinum, silver, antimony or bismuth. Fine wires increase the surface area of the junction and help in complete absorption of heat from the IR radiation 1. Reference junction

Bo l o m et e r

Golay cell It is also called as gas thermometer. It consists of a cylindrical chamber, filled with xenon gas. Walls of this chamber are blackened for the complete absorption of heat supplied by the IR radiation incident on it. One end of this cylinder is fitted with an IR transparent window. Another end contains a flexible diaphragm which is silvered from outside. The chamber also contains a phototube.When the IR radiation enters this chamber. the blackened walls absorb heat provided by the radiation. This in turn heats the xenon gas inside the chamber. The xenon gas expands and exerts The curvature pressure on the flexible diaphragm depends on the increase in the temperature of the xenon gas, which in turn depends on the heat absorbed by it, which further dépends on the intensity of the incident IR radiation. When the IR radiation falls on the silvered diaphragm, they reflect back in the chamber and fall on the photosensitive surface of a phototube., Fending on the curvature of the flexible diaphragm, a definite fraction of reflected beam strikes the active surface ot a phototube. This leads to a change in the photocurrent. which can related to the power of IR.

Thermistors

Pyroelectric substances are the dielectric materials having special thermal and electrical properties. Certain such as lithium Iantatate, barium titanate and triglycine sulfate possess pyroelectric property. They produce temperature sensitive dipole moments. To construct a pyroelectric detector, a pyroelectric substance is placed between two electrodes, one of which has an IR transparent window. Two electrodes are connected to each other via a voltmeter . Molecular dipoles in a pyroelectric substance are randomly oriented at room temperature. When the IR radiation falls upon a pyroelectric substance, it absorbs energy from the radiation. This energy is utilized in aligning the molecular dipoles of the pyroelectric substance. Pyroelectric detectors

Infrared light at wavelengths sometimes beyond 5 μm can be detected with lead salt detectors , e.g. containing lead selenide (PbSe) or lead sulfide (PbS). They are photoconductors , not photodiodes, i.e., they do not contain a p–n junction but exhibit a reduction in electrical resistance caused by incident light, which induces intraband transitions. Another detector technology, which is widely used, is based on photoresistors containing mercury cadmium telluride. Detection at rather long wavelengths (partly beyond 12 μm ) is po s sibl e . PHOTOCONDUCTIVITY DETECTORS