ELECTRICAL INSTALLATION AND MAINTENANCE QUARTER 2 LESSON: INSTALL ELECTRICAL LIGHTING SYSTEMS,AUXILIARY OUTLET AND LIGHTING FEXTURES
Learning Competencies Objectives At the end of the lesson, 95% of the students can: Explain how to control a lamp in two location using two 3way switch. Execute wiring termination and standard procedure in controlling a lamp in two different location. Demonstrate confidence, cooperation and safety procedure.
Controlling a lamp in two location using two 3way switch
c c L2 L1 3-Way Switch 3-Way Switch Lamp Travelers Wire SOURCE AC
3way switch
Standard wiring procedure. Wear personal protective equipment. Be sure that the source are isolated. Hot wire must connect to the common of first 3wayswitch. Travelers contact must connect between two 3way switch. Connect the common of second 3way switch to the line side of the socket. Neutral wire must connect to neutral side of the lamp socket Checked for continuity test to know if there is short circuit. Note: Be sure that all lamp are remove from the socket.
RUBRICS FOR EVALUATION CRITERIA 1. Safety procedure 20% 2. Standard wiring procedure 60% 3. Group cooperation 20% TOTAL 100%
Assignment Draw a wiring diagram in controlling a lamp in two location in a short bond paper and label the part of the circuit. 2. Determine the contact of the switch if it is in on/off position